Publications by authors named "Claudia Prieto"

Background: Cardiac cine MRI is the gold standard for cardiac functional assessment, but the inherently slow acquisition process creates the necessity of reconstruction approaches for accelerated undersampled acquisitions. Several regularization approaches that exploit spatial-temporal redundancy have been proposed to reconstruct undersampled cardiac cine MRI. More recently, methods based on supervised deep learning have been also proposed to further accelerate acquisition and reconstruction.

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to create and assess a new method for conducting free-breathing 3D whole-heart Cardiac Magnetic Resonance Angiography (CMRA) without contrast agents at a lower magnetic field strength of 0.55T.
  • To achieve this, researchers optimized pulse sequences and imaging techniques, incorporating advanced methods like low-rank denoising and respiratory motion correction, and tested their approach on 11 healthy volunteers.
  • Results showed that the new method produced high-quality images with minimal artifacts in just 6 minutes, matching the performance of higher field strength systems, paving the way for future testing in patients with heart conditions.
View Article and Find Full Text PDF

Purpose: To develop a 3D free-breathing cardiac multi-parametric mapping framework that is robust to confounders of respiratory motion, fat, and B1+ inhomogeneities and validate it for joint myocardial T1 and T1ρ mapping at 3T.

Methods: An electrocardiogram-triggered sequence with dual-echo Dixon readout was developed, where nine cardiac cycles were repeatedly acquired with inversion recovery and T1ρ preparation pulses for T1 and T1ρ sensitization. A subject-specific respiratory motion model relating the 1D diaphragmatic navigator to the respiration-induced 3D translational motion of the heart was constructed followed by respiratory motion binning and intra-bin 3D translational and inter-bin non-rigid motion correction.

View Article and Find Full Text PDF

Background: The diagnosis of myocarditis by cardiovascular magnetic resonance (CMR) requires the use of T2 and T1 weighted imaging, ideally incorporating parametric mapping. Current two-dimensional (2D) mapping sequences are acquired sequentially and involve multiple breath-holds resulting in prolonged scan times and anisotropic image resolution. We developed an isotropic free-breathing three-dimensional (3D) whole-heart sequence that allows simultaneous T1 and T2 mapping and validated it in patients with suspected myocarditis.

View Article and Find Full Text PDF

Heart failure (HF) affects 64 million people globally with enormous societal and healthcare costs. Myocardial fibrosis, characterised by changes in collagen content drives HF. Despite evidence that collagen type III (COL3) content changes during myocardial fibrosis, in vivo imaging of COL3 has not been achieved.

View Article and Find Full Text PDF

Background: Coronary computed tomography angiography (CCTA) is recommended as the first-line diagnostic imaging modality in low-to-intermediate-risk individuals suspected of stable coronary artery disease (CAD). However, CCTA exposes patients to ionizing radiation and potentially nephrotoxic contrast agents. Invasive coronary angiography is the gold-standard investigation to guide coronary revascularisation strategy; however, invasive procedures incur an inherent risk to the patient.

View Article and Find Full Text PDF

Background: Active inflammatory bowel disease (A-IBD) but not remission (R-IBD) has been associated with an increased risk of cardiovascular death and hospitalization for heart failure.

Objectives: Using cardiovascular magnetic resonance (CMR), this study aims to assess adverse myocardial remodeling in patients with IBD in correlation with disease activity.

Methods: Forty-four IBD patients without cardiovascular disease (24 female, median-age: 39.

View Article and Find Full Text PDF

Purpose: To develop a framework for simultaneous three-dimensional (3D) mapping of , , and fat signal fraction in the liver at 0.55 T.

Methods: The proposed sequence acquires four interleaved 3D volumes with a two-echo Dixon readout.

View Article and Find Full Text PDF

Background: Cardiovascular magnetic resonance (CMR) is an important imaging modality for the assessment of heart disease; however, limitations of CMR include long exam times and high complexity compared to other cardiac imaging modalities. Recently advancements in artificial intelligence (AI) technology have shown great potential to address many CMR limitations. While the developments are remarkable, translation of AI-based methods into real-world CMR clinical practice remains at a nascent stage and much work lies ahead to realize the full potential of AI for CMR.

View Article and Find Full Text PDF
Article Synopsis
  • A new imaging technique was developed for 3D whole-heart mapping using motion compensation at a lower magnetic field strength (0.55T) to improve image resolution and quality while patients breathe normally.
  • This technique involves acquiring three different water/fat volumes and utilizes image navigators for better motion correction and image reconstruction; initial tests on healthy volunteers showed promising results compared to traditional methods.
  • Validation results indicated high accuracy and quick scan times (about 7 minutes), with the new method providing measurements comparable to traditional sequences in terms of myocardial T1 and T2 values, ensuring its potential for clinical use.
View Article and Find Full Text PDF

Contrast enhanced pulmonary vein magnetic resonance angiography (PV CE-MRA) has value in atrial ablation pre-procedural planning. We aimed to provide high fidelity, ECG gated PV CE-MRA accelerated by variable density Cartesian sampling (VD-CASPR) with image navigator (iNAV) respiratory motion correction acquired in under 4 min. We describe its use in part during the global iodinated contrast shortage.

View Article and Find Full Text PDF

Purpose: A 2D image navigator (iNAV) based 3D whole-heart sequence has been used to perform MRI and PET non-rigid respiratory motion correction for hybrid PET/MRI. However, only the PET data acquired during the acquisition of the 3D whole-heart MRI is corrected for respiratory motion. This study introduces and evaluates an MRI-based respiratory motion correction method of the complete PET data.

View Article and Find Full Text PDF

Background: Cardiovascular magnetic resonance (CMR) is an important imaging modality for the assessment and management of adult patients with congenital heart disease (CHD). However, conventional techniques for three-dimensional (3D) whole-heart acquisition involve long and unpredictable scan times and methods that accelerate scans via k-space undersampling often rely on long iterative reconstructions. Deep-learning-based reconstruction methods have recently attracted much interest due to their capacity to provide fast reconstructions while often outperforming existing state-of-the-art methods.

View Article and Find Full Text PDF

Aims: Unstable atherosclerotic plaques have increased activity of myeloperoxidase (MPO). We examined whether molecular magnetic resonance imaging (MRI) of intraplaque MPO activity predicts future atherothrombosis in rabbits and correlates with ruptured human atheroma.

Methods And Results: Plaque MPO activity was assessed in rabbits ( = 12) using the MPO-gadolinium (Gd) probe at 8 and 12 weeks after induction of atherosclerosis and before pharmacological triggering of atherothrombosis.

View Article and Find Full Text PDF

Background: Three dimensional, whole-heart (3DWH) MRI is an established non-invasive imaging modality in patients with congenital heart disease (CHD) for the diagnosis of cardiovascular morphology and for clinical decision making. Current techniques utilise diaphragmatic navigation (dNAV) for respiratory motion correction and gating and are frequently limited by long acquisition times. This study proposes and evaluates the diagnostic performance of a respiratory gating-free framework, which considers respiratory image-based navigation (iNAV), and highly accelerated variable density Cartesian sampling in concert with non-rigid motion correction and low-rank patch-based denoising (iNAV-3DWH-PROST).

View Article and Find Full Text PDF

Purpose: Simultaneous PET-MRI improves inflammatory cardiac disease diagnosis. However, challenges persist in respiratory motion and mis-registration between free-breathing 3D PET and 2D breath-held MR images. We propose a free-breathing non-rigid motion-compensated 3D T -mapping sequence enabling whole-heart myocardial tissue characterization in a hybrid 3T PET-MR system and provides non-rigid respiratory motion fields to correct also simultaneously acquired PET data.

View Article and Find Full Text PDF

Background: Quantification of three-dimensional (3D) cardiac anatomy is important for the evaluation of cardiovascular diseases. Changes in anatomy are indicative of remodeling processes as the heart tissue adapts to disease. Although robust segmentation methods exist for computed tomography angiography (CTA), few methods exist for whole-heart cardiovascular magnetic resonance angiograms (CMRA) which are more challenging due to variable contrast, lower signal to noise ratio and a limited amount of labeled data.

View Article and Find Full Text PDF

Background: Incomplete atrial lesions resulting in pulmonary vein-left atrium reconnection after pulmonary vein antrum isolation (PVAI), are related to atrial fibrillation (AF) recurrence. Unfortunately, during the PVAI procedure, fluoroscopy and electroanatomic mapping cannot accurately determine the location and size of the ablation lesions in the atrial wall and this can result in incomplete PVAI lesions (PVAI-L) after radiofrequency catheter ablation (RFCA).

Aim: We seek to evaluate whether cardiac magnetic resonance (CMR), immediately after RFCA of AF, can identify PVAI-L by characterizing the left atrial tissue.

View Article and Find Full Text PDF
Article Synopsis
  • This study evaluated the use of liver MR fingerprinting (MRF) to quantitatively assess and diagnose different focal liver lesions in 89 participants averaging 62 years old.
  • The MRF measurements performed comparably to standard MRI assessments, showing strong agreement for T1 values and moderate for T2, while also demonstrating good repeatability across measurements.
  • A combination of metrics derived from MRF distinguished between benign and malignant lesions effectively, achieving a high diagnostic accuracy with an area under the curve (AUC) of 0.92.
View Article and Find Full Text PDF

Objectives: Visualizing left atrial anatomy including the pulmonary veins (PVs) is important for planning the procedure of pulmonary vein isolation with ablation in patients with atrial fibrillation (AF). The aims of our study are to investigate the feasibility of the 3D whole-heart bright-blood and black-blood phase-sensitive (BOOST) inversion recovery sequence in patients with AF scheduled for ablation or electro-cardioversion, and to analyze the correlation between image quality and heart rate and rhythm of patients.

Methods: BOOST was performed for assessing PVs both with T2 preparation pre-pulse (T2prep) and magnetization transfer preparation (MTC) in 45 patients with paroxysmal or permanent AF scheduled for ablation or electro-cardioversion.

View Article and Find Full Text PDF

Cine cardiac magnetic resonance (CMR) imaging is considered the gold standard for cardiac function evaluation. However, cine CMR acquisition is inherently slow and in recent decades considerable effort has been put into accelerating scan times without compromising image quality or the accuracy of derived results. In this article, we present a fully-automated, quality-controlled integrated framework for reconstruction, segmentation and downstream analysis of undersampled cine CMR data.

View Article and Find Full Text PDF

Background: Coronary magnetic resonance angiography (coronary MRA) is increasingly being considered as a clinically viable method to investigate coronary artery disease (CAD). Accurate determination of the trigger delay to place the acquisition window within the quiescent part of the cardiac cycle is critical for coronary MRA in order to reduce cardiac motion. This is currently reliant on operator-led decision making, which can negatively affect consistency of scan acquisition.

View Article and Find Full Text PDF

Introduction: Left atrial appendage (LAA) thrombus is the most common source of embolization in atrial fibrillation (AF). Transesophageal echocardiography (TEE) is the gold standard method for LAA thrombus exclusion. Our pilot study aimed to compare the efficacy of a new non-contrast-enhanced cardiac magnetic resonance (CMR) sequence (BOOST) with TEE for the detection of LAA thrombus and to evaluate the usefulness of BOOST images for planning radiofrequency catheter ablation (RFCA) compared with left atrial (LA) contrast-enhanced computed tomography (CT).

View Article and Find Full Text PDF
Article Synopsis
  • - The study aims to enhance an adiabatic method for accurately measuring spin-lock relaxation in the heart using advanced MRI techniques at 3 Tesla (3T).
  • - Researchers optimized various adiabatic spin-lock (aSL) modules for better performance against magnetic field inhomogeneities and validated them through simulations and tests on phantoms and healthy subjects.
  • - Results indicated that the optimized aSL methods provided significantly improved image quality, precision, and reproducibility in relaxation time measurements compared to traditional methods, with specific modules showing the best performance in both healthy individuals and patients with cardiovascular conditions.
View Article and Find Full Text PDF