Cardiac implantable electronic devices (CIEDs) are often important for regulating cardiac rate and rhythm. Pacemakers and defibrillators are among the top 10 most implanted medical devices, with > 1.5 million devices implanted annually.
View Article and Find Full Text PDFBackground: Cardiac Implantable Electronic Devices (CIED) include pulse generators and leads. In some implanting centers, it is a common practice to combine devices with leads from different companies. Case series have reported episodic high-impedance changes in Boston Scientific CIEDs with competitor leads.
View Article and Find Full Text PDFA high-risk left-sided posterolateral manifest accessory pathway (AP) was identified in a 49-year-old man. Two prior ablations had failed. A repeat procedure using 3D electroanatomic mapping demonstrated an extremely oblique AP.
View Article and Find Full Text PDFJACC Clin Electrophysiol
August 2020
Objectives: This study evaluated the impact of contact force-guided radiofrequency ablation versus cryoballoon ablation on quality of life and health care utilization.
Background: Traditional outcome parameters, such as arrhythmia-free survival, are insufficient to evaluate the clinical impact of atrial fibrillation (AF), as it fails to the capture patient- and health system-level differences in treatment approaches.
Methods: The CIRCA-DOSE (Cryoballoon Vs.
Background: Contemporary guidelines recommend that atrial fibrillation (AF) be classified into paroxysmal and persistent AF based on clinical assessment, with these categorizations forming the basis of therapeutic recommendations. While pragmatic, clinical assessment may introduce misclassification errors, which may impact treatment decisions. We sought to determine the relationship between AF classification, baseline AF burden, and post-ablation arrhythmia outcomes.
View Article and Find Full Text PDFAn 18 year old male with an incompletely healed clavicle fracture presented with unexplained syncope. Subsequent investigations were consistent with a diagnosis of arrhythmogenic right ventricular cardiomyopathy (ARVC). A subcutaneous implantable cardioverter-defibrillator (S-ICD) was successfully implanted and defibrillation threshold (DFT) testing performed as per standard protocol.
View Article and Find Full Text PDFBackground: Advanced generation ablation technologies have been developed to achieve more effective pulmonary vein isolation (PVI) and minimize arrhythmia recurrence after atrial fibrillation (AF) ablation.
Methods: We randomly assigned 346 patients with drug-refractory paroxysmal AF to contact force-guided radiofrequency ablation (CF-RF; n=115), 4-minute cryoballoon ablation (Cryo-4; n=115), or 2-minute cryoballoon ablation (Cryo-2; n=116). Follow-up was 12 months.
Indian J Crit Care Med
February 2019
Unlabelled: We report an unusual complication of permanent pacemaker (PPM) implantation in a patient with a temporary transvenous pacemaker (TVP) , in which the TVP lead formed a knot around the newly-placed right ventricular (RV) lead, complicating TVP removal. The case underscores the fact that suboptimal TVP lead placement, such as looping in the RV, can result in complications during implantation of a permanent pacemaker.
How To Cite This Article: Wiens EJ, Seifer CM Inadvertent Removal of a Right Ventricular Pacemaker Lead by a Knotted Transvenous Pacing Wire.
Background: Evidence regarding the incremental benefit of cardiac resynchronization therapy (CRT) with a defibrillator (CRT-D) versus without (CRT-P) in elderly patients with heart failure is limited. We compared mortality and cardiac hospitalisation between CRT-D and CRT-P in the elderly.
Methods: A retrospective chart review identified all consecutive patients with age ≥75 with CRT implantation over the last 10 years at a Canadian tertiary care cardiac centre.
Takotsubo cardiomyopathy (TTC) may clinically mimic an acute coronary syndrome and is most often associated with an acute stressor. In this case report, we describe an atypical case of TTC triggered by multiple subacute stressors rather than 1 acute stressor. We also report TTC and transient global amnesia occurring concurrently.
View Article and Find Full Text PDFObjectives: The objectives of this study were to evaluate the effectiveness of a physician notification system for atrial fibrillation (AF) detected on cardiac devices, and to assess predictors of anticoagulation in patients with device-detected AF.
Methods: In 2013, a physician notification system for AF detected on a patient's CIED [including pacemakers, implantable cardioverter defibrillators (ICD) or cardiac resynchronization therapy (CRT) devices] was implemented, with a recommendation to consider oral anticoagulation in high-risk patients. We prospectively investigated the effectiveness of this system, and evaluated both patient and physician predictors of anticoagulation, as well as factors influencing physician decision making in prescribing anticoagulation.
Objectives: The objectives of this study were to evaluate the effectiveness of a physician notification system for atrial fibrillation (AF) detected on cardiac devices, and to assess predictors of anticoagulation in patients with device-detected AF.
Methods: In 2013, a physician notification system for AF detected on a patient's CIED [including pacemakers, implantable cardioverter defibrillators (ICD) or cardiac resynchronization therapy (CRT) devices] was implemented, with a recommendation to consider oral anticoagulation in high-risk patients. We prospectively investigated the effectiveness of this system, and evaluated both patient and physician predictors of anticoagulation, as well as factors influencing physician decision making in prescribing anticoagulation.
J Am Soc Echocardiogr
June 2013
Background: Bicuspid aortic valves (BAVs) are associated with aortopathy. Recent studies suggest that aortic dilatation is more likely to be seen with left-right coronary cusp fusion (type I) compared with right-noncoronary cusp fusion (type II). The aim of this study was to investigate the association between BAV morphology and patterns of aortopathy.
View Article and Find Full Text PDFBackground: There is a relative paucity of data linking inappropriate implantable cardioverter-defibrillator (ICD) shocks to adverse clinical outcomes.
Objective: To examine the association between inappropriate ICD shocks and mortality or heart transplantation in a large population cohort.
Design, Setting, Patients: A cohort study which included all subjects who underwent ICD implantation between 1998 and 2008 and were followed up at our institution.
While the overall prognosis of syncope is favorable, the identification of individuals with a potentially life-threatening cause is of paramount importance. Cardiac syncope is associated with an elevated risk of mortality, and includes both primary arrhythmic and obstructive etiologies. Identification of these individuals is contingent on careful clinical assessment and judicious use of diagnostic investigations.
View Article and Find Full Text PDFBackground: There are no reported randomized controlled trials of triple antithrombotic therapy (TT; aspirin plus a thienopyridine plus vitamin K antagonist) vs dual antiplatelet therapy (DAPT; aspirin plus a thienopyridine) among patients undergoing percutaneous coronary intervention with stenting (PCI-S). A systematic review and meta-analysis was undertaken to assess the risk of bleeding among patients receiving TT after PCI-S.
Methods: Electronic databases were searched for studies reporting bleeding among patients receiving TT after PCI-S.
A man aged 75 years and with nonischemic cardiomyopathy had implantation of a biventricular implantable cardiac defibrillator (ICD). Consistent biventricular pacing was limited by intermittent T-wave oversensing (TWOS). A strategy of left-ventricular-only pacing was used to eliminate TWOS.
View Article and Find Full Text PDFMarfan syndrome is associated with a high incidence of aortic root aneurysm and life-threatening aortic dissection. With the successful use of surgical aortic root replacement, dissection-related mortality has been significantly reduced. We present the case of a patient with Marfan syndrome who presented with heart failure secondary to an unusual graft-related complication 14 years after a Bentall procedure.
View Article and Find Full Text PDF