Power distribution of progressive power lenses provides usable regions based on power distribution analysis. However, recent studies demonstrated that these regions are not always used for certain tasks as predicted. This work determines the concordance between the actual region of lens use and compares it with the theoretically located regions.
View Article and Find Full Text PDFAdaptive optics (AO) visual simulators are excellent platforms for non-invasive simulation visual performance with new intraocular lens (IOL) designs, in combination with a subject own ocular aberrations and brain. We measured the through focus visual acuity in subjects through a new refractive IOL physically inserted in a cuvette and projected onto the eye's pupil, while aberrations were manipulated (corrected, or positive/negative spherical aberration added) using a deformable mirror (DM) in a custom-developed AO simulator. The IOL increased depth-of-focus (DOF) to 1.
View Article and Find Full Text PDFInt J Environ Res Public Health
November 2022
Early detection and treatment of refractive defects during school age are essential to avoid irreversible future vision loss and potential school problems. Previously, vision screening of preschool children used methods based on subjective visual acuity; however, technologies such as photorefraction have promoted the detection of refractive errors quickly and easily. In this study, 1347 children from 10 schools in Madrid aged 4 to 12 years participated in a program of early detection of visual problems, which consisted of visual screening composed of anamnesis and photorefraction with a PlusOptix A12R.
View Article and Find Full Text PDFA better understanding of visual performance with Multifocal Contact Lenses (MCLs) is essential, both in young eyes, where MCLs may be prescribed to control the progression of myopia wherein the MCLs optics interact with accommodation, and in presbyopes, where MCLs are increasingly used to compensate the lack of accommodation. In this study, we evaluated the through focus visual acuity (TFVA) with center-near MCLs of three additions (low, medium and high) and without an addition (NoLens) in 10 young adults and 5 presbyopes. We studied the effect of accommodation, age and pupil diameter (in cyclopleged subjects) on visual performance.
View Article and Find Full Text PDFConvolved images are often used to simulate the effect of ocular aberrations on image quality, where the retinal image is simulated by convolving the stimulus with the point spread function derived from the subject's aberrations. However, some studies have shown that convolved images are perceived far more degraded than the same image blurred with optical defocus. We hypothesized that the positive interactions between the monochromatic and chromatic aberrations in the eye are lost in the convolution process.
View Article and Find Full Text PDFVisual simulators aim at evaluating vision with ophthalmic corrections prior to prescription or implantation of intraocular lenses (IOLs) in the patient's eye. In the present study, we present the design, implementation, and validation of a new IOL-in-cuvette channel in an Adaptive Optics visual simulator, which provides an alternative channel for pre-operative simulation of vision with IOLs. The IOL is projected on the pupil's plane of the subject by using a Rassow system.
View Article and Find Full Text PDFDue to chromatic aberration, blue images are defocused when the eye is focused to the middle of the visible spectrum, yet we normally are not aware of chromatic blur. The eye suffers from monochromatic aberrations which degrade the optical quality of all images projected on the retina. The combination of monochromatic and chromatic aberrations is not additive and these aberrations may interact to improve image quality.
View Article and Find Full Text PDFWe have measured the ocular transverse chromatic aberration (TCA) in 11 subjects using 2D-two-color Vernier alignment, for two pupil diameters, in a polychromatic adaptive optics (AO) system. TCA measurements were performed for two pupil diameters: for a small pupil (2-mm), referred to as 'optical TCA' (oTCA), and for a large pupil (6-mm), referred to 'perceived TCA' (pTCA). Also, the TCA was measured through both natural aberrations (HOAs) and AO-corrected aberrations.
View Article and Find Full Text PDFPurpose: To measure monochromatic aberrations at various wavelengths in eyes implanted with the Clareon monofocal aspheric intraocular lens (IOL) (Alcon Laboratories, Inc., Fort Worth, TX). The authors estimated longitudinal chromatic aberration (LCA), modulation transfer functions (MTFs), and the impact of interactions between chromatic and monochromatic aberrations on retinal image quality.
View Article and Find Full Text PDFPurpose: Adaptive Optics allows measurement and manipulation of the optical aberrations of the eye. We review two Adaptive Optics set-ups implemented at the Visual Optics and Biophotonics Laboratory, and present examples of their use in better understanding of the role of optical aberrations on visual perception, in normal and treated eyes.
Recent Findings: Two systems (AOI and AOII) are described that measure ocular aberrations with a Hartmann-Shack wavefront sensor, which operates in closed-loop with an electromagnetic deformable mirror, and visual stimuli are projected in a visual display for psychophysical measurements.
While multifocal intraocular lenses (MIOLs) are increasingly implanted to correct for presbyopia, how one sees with a multifocal correction is hard to explain and imagine. The current study evaluates the quality of various visual simulating technologies by comparing vision with simulated MIOLs pre-operatively and the implanted MIOLs post-operatively in the same patients. Two simulation platforms were used: (1) a custom-developed adaptiveoptics (AO) system, with two visual simulator devices: a spatial light modulator (SLM) and an optotunable lens operating under temporal multiplexing (SimVis); and (2) a wearable, binocular, large field of view SimVis2Eyes clinical simulator (SimVis Gekko, 2Eyes Vision, Madrid, Spain).
View Article and Find Full Text PDFWe investigated the effect of induced astigmatism on subjective best focus and on visual acuity in 28 subjects of different ages (pre-presbyopic and presbyopic) and with different refractive profiles (emmetropes and astigmats). Measurements were performed using a custom-developed Adaptive Optics system, which allowed correction of high order aberrations and induction of astigmatism (0.5, 1, 1.
View Article and Find Full Text PDFAdaptive optics (AO) visual simulators based on deformable mirrors, spatial light modulators or optotunable lenses are increasingly used to simulate vision through different multifocal lens designs. However, the correspondence of this simulation with that obtained through real intraocular lenses (IOLs) tested on the same eyes has not been, to our knowledge, demonstrated. We compare through-focus (TF) optical and visual quality produced by real multifocal IOLs (M-IOLs) -bifocal refractive and trifocal diffractive- projected on the subiect's eye with those same designs simulated with a spatial light modulator (SLM) or an optotunable lens working in temporal multiplexing mode (SimVis technology).
View Article and Find Full Text PDFTunable lenses are becoming ubiquitous, in applications including microscopy, optical coherence tomography, computer vision, quality control, and presbyopic corrections. Many applications require an accurate control of the optical power of the lens in response to a time-dependent input waveform. We present a fast focimeter (3.
View Article and Find Full Text PDFSpatial-light-modulators (SLM) are increasingly used as active elements in adaptive optics (AO) systems to simulate optical corrections, in particular multifocal presbyopic corrections. In this study, we compared vision with lathe-manufactured multi-zone (2-4) multifocal, angularly and radially, segmented surfaces and through the same corrections simulated with a SLM in a custom-developed two-active-element AO visual simulator. We found that perceived visual quality measured through real manufactured surfaces and SLM-simulated phase maps corresponded highly.
View Article and Find Full Text PDF