While macroglossia is a newly accepted component of brachycephalic obstructive airway syndrome (BOAS) in dogs, macroglossia with increased tongue fat is a well-known cause for obstructive sleep apnea (OSA) in people, and targeted reduction procedures such as midline glossectomy are used to treat people with OSA. While midline glossectomy has been described in dogs, tissue contributions to macroglossia have not been characterized. The purpose of this retrospective, descriptive, case-control study was to describe and compare volumetric dimensions of the tongue and tongue fat in brachycephalic (BC) and mesaticephalic (MC) dogs using CT images.
View Article and Find Full Text PDFCase Description: A 3-year-old 31.1-kg castrated male mixed-breed dog was evaluated because of a 1- to 2-week history of paraparesis, knuckling of the hind feet, and difficulty posturing to urinate or defecate.
Clinical Findings: The dog was paraparetic but weakly ambulatory with a kyphotic posture, a mildly decreased patellar reflex in the right pelvic limb, increased tone in both pelvic limbs, and marked hyperesthesia on paraspinal palpation of the lumbar region.
Vet Radiol Ultrasound
September 2020
Magnetic resonance imaging (MRI) is commonly used to diagnose degenerative lumbosacral stenosis; however, studies show limited correlation between imaging and clinical signs. The purpose of this prospective observer agreement study was to use dynamic MRI of the lumbosacral (LS) spine of healthy dogs to determine reliable reference ranges. Twenty-two healthy large breed dogs were prospectively enrolled.
View Article and Find Full Text PDFRespiratory-induced organ displacement during image acquisition can produce motion artifacts and variation in spatial localization of an organ in diagnostic computed tomography (CT) examinations. The purpose of this prospective study was to quantify respiratory-induced abdominal organ displacement in dorsal and ventral recumbency using five normal dogs. All dogs underwent CT examinations using 64 multidetector row CT (64-MDCT).
View Article and Find Full Text PDFObjective: To determine the incidence of adverse events within 24 hours after contrast-enhanced ultrasonography (CEUS) in dogs and cats and compare the risk of death within 24 hours after imaging for animals that underwent ultrasonography with and without injection of a contrast agent.
Design: Retrospective case-control study.
Animals: 750 animals (411 case dogs, 238 control dogs, 77 case cats, and 24 control cats).
The computed tomographic (CT) findings of histopathologically confirmed nasopharyngeal polyps are described in 13 cats. Most polyps were mildly hypoattenuating to adjacent muscles and isoattenuating to soft-tissue (n= 13), homogeneous (n = 12) and with ill-defined borders (n = 10) on precontrast images. After contrast medium administration, the polyps were homogeneous (n = 11), with well-defined borders (n = 13), oval (n = 13), and had rim enhancement (n = 13).
View Article and Find Full Text PDFForty-seven patients with a known history of thoracic trauma or clinical suspicion of pneumothorax were selected for thoracic imaging. The patient population was composed of 42 dogs and five cats. Standard vertical beam (VB) left and right lateral and ventrodorsal/dorsoventral (VD/DV) projections were obtained for each patient, and at least one horizontal beam (HB) projection (VD projection made in lateral recumbency).
View Article and Find Full Text PDFVet Radiol Ultrasound
September 2011
Computed tomography (CT) and thoracic radiography were performed in nonsedated, nonanesthetized, cats with thoracic disease. The final diagnosis was obtained with echocardiography, cytology, histopathology, necropsy, or response to therapy. For CT imaging, cats were in a positioning device using a 16 multislice helical CT system.
View Article and Find Full Text PDFThe VetMousetrap, a novel device that allows computed tomography (CT) of awake cats and provides a clinically supportive environment, is described. Ten normal cats were used to test the device for ambient internal oxygen, carbon dioxide levels, and temperature. Twenty-two awake normal cats were imaged using a 16-multislice helical CT unit to evaluate dose-equivalent protocols.
View Article and Find Full Text PDF