The current analytical methods of stable antimony isotopes are cumbersome and not suitable for rock samples with low antimony content (<1 μg/g). In this study, we propose a new protocol for antimony isotopic analysis with a single column of AG50W-X8 resin and antimony standard doping. This method separates antimony effectively from matrices and then mixes it with the Sb standard.
View Article and Find Full Text PDFLarge areas of arid regions in the Tibetan Plateau (TP) are undergoing desertification and subsequent aeolian emission and transport. The contribution of TP soils to the atmospheric aerosol burden in Asia and elsewhere is not known. Here, we use Hf, Nd, and Sr isotopes to distinguish the TP from other Asian dust-producing regions and compare the signatures to sediments in major dust sink regions.
View Article and Find Full Text PDFThis study presents a practical method for high-precision Cu and Pb isotope determination without column chemistry for bronze materials using MC-ICP-MS. The standard-sample bracketing method combined with Ga internal normalization (SSBIN) was used to correct the instrumental mass bias during Cu isotopic analysis. The effects of acidity mismatch, concentration mismatch, and matrix effect were rigorously evaluated using a Nu Plasma II MC-ICP-MS in the wet plasma mode.
View Article and Find Full Text PDFThis study performed a series of comparable experiments (with or without column chromatography) to evaluate whether non-deviated Cu isotope ratios can be obtained directly by Nu Plasma II multi-collector inductively coupled plasma-mass spectrometry (MC-ICP-MS) using standard-sample bracketing with Ga as internal mass bias correction model (C-SSBIN) without column chromatography. Twelve Cu-dominated minerals (copper plate, native copper, chalcopyrite, bornite, chalcocite, digenite, covellite, tetrahedrite, azurite, malachite, atacamite, and cyanotrichite) displayed little drift in δCu values compared with those of minerals with column chromatography, with ΔδCu ranging from -0.04 to +0.
View Article and Find Full Text PDFTo investigate the large-scale trace element deposition and anthropogenic pollution in mountain glaciers of the northeastern Tibetan Plateau (TP) and its surrounding regions, we analyzed Al and 13 trace elements (As, Cd, Co, Cr, Cs, Cu, Mn, Mo, Ni, Pb, Sb, V, and Zn) in glacier snowpacks collected at the Yuzhufeng, Laohugou No.12, and Qiyi glaciers (YG, LG12, and QG, respectively) in the northeastern TP as well as in the Miaoergou Glacier (MG) in the eastern Tianshan Mountains in June 2017. The concentrations and enrichment factors (EFs) of most trace elements (e.
View Article and Find Full Text PDFIn the present study we set up a femtosecond laser ablation MC-ICP-MS method for lead isotopic analysis. Pb isotopic composition of fifteen copper (brass, bronze) standard samples from the National Institute of Standards Material were analyzed using the solution method (MC-ICP-MS) and laser method (fLA-MC-ICPMS) respectively, the results showed that the Pb isotopic composition in CuPb12 (GBW02137) is very homogeneous, and can be used as external reference material for Pb isotopic in situ analysis. On CuPb12 112 fLA-MC-ICPMS Pb isotope analysis, the weighted average values of the Pb isotopic ratio are in good agreement with the results analyzed by bulk solution method within 2sigma error, the internal precision RSEs of the 208 Pb/204 Pb ratio and 207 Pb/206 Pb ratio are less than 90 and 40 ppm respectively, and the external precision RSDs of them are less than 60 and 30 ppm respectively.
View Article and Find Full Text PDF