Liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) is the most common analytical technique for per- and polyfluoroalkyl substances (PFASs) research and monitoring. The PFAS identification requires a minimum of two multiple reaction monitoring (MRM) transition ions as quantifier transition ion and qualifier transition ion, respectively. The second transition ion abundance for perfluoropentanoic acid (PFPeA) and perfluobutanoic acid (PFBA) is too low for practical use.
View Article and Find Full Text PDFObjective: To explore the value of maximal contrast-enhanced (CEmax) range using contrast-enhanced CT (CECT) imaging in differentiating the pathological subtypes and risk subgroups of thymic epithelial tumors (TETs).
Methods: The pre-treatment-CECT images of 319 TET patients from May 2012 to November 2021 were analyzed retrospectively. The CEmax was defined as the maximum difference between the CT value of the solid tumor on pre-contrast and contrast-enhanced images.
Background: To validate a contrast-enhanced CT (CECT)-based radiomics model (RM) for differentiating various risk subgroups of thymic epithelial tumors (TETs).
Methods: A retrospective study was performed on 164 patients with TETs who underwent CECT scans before treatment. A total of 130 patients (approximately 79%, from 2012 to 2018) were designated as the training set, and 34 patients (approximately 21%, from 2019 to 2021) were designated as the testing set.
Fibroblast activation protein-α (FAP) is a type II integral serine protease that is specifically expressed by activated fibroblasts. Cancer-associated fibroblasts (CAFs) in the tumor stroma have an abundant and stable expression of FAP, which plays an important role in promoting tumor growth, invasion, metastasis, and immunosuppression. For example, in females with a high incidence of breast cancer, CAFs account for 50-70% of the cells in the tumor's microenvironment.
View Article and Find Full Text PDFThis study demonstrated the signal enhancement interference from soluble iron (Fe) during mercury (Hg) determination in water by cold vapor atomic absorption spectrometry (CV-AAS) using sodium borohydride (NaBH) as reductant. In the presence of 50 mg L soluble Fe, Hg values will be overestimated by around 25%. The reason for the Hg signal enhancement is still unclear, but it is speculated to be attributable to the catalyst function for the equilibrium reduction reaction between Hg and BH from the atomic Fe formed at the same time.
View Article and Find Full Text PDFAn amendment to this paper has been published and can be accessed via a link at the top of the paper.
View Article and Find Full Text PDFTo evaluate the role of conventional contrast-enhanced CT (CECT) imaging and dual-energy spectral CT (DECT) perfusion imaging in differentiating the WHO histological subtypes of thymic epithelial tumours (TETs). Eighty-eight patients with TETs who underwent DECT perfusion scans (n = 51) and conventional CT enhancement scans (n = 37) using a GE Discovery CT750 HD scanner were enrolled in this study. The mean maximal contrast-enhanced range (mean CEmax) and the perfusion and spectral parameters of the lesions were analysed.
View Article and Find Full Text PDFBased on selective sorption of bromide, bromoacetic acids (BAA) and bromomethanes on solid-phase extraction (SPE) cartridges, a sensitive and convenient method was developed for the determination of bromate in waters by inductively coupled plasma mass spectrometry (ICP-MS). Dionex OnGuard Ag and reversed-phase (RP) cartridges were tested for retention characteristics for bromide, BAA and bromomethanes. When a sample acidified with nitric acid was passed through an RP cartridge, BAA and bromomethanes were retained, afterwards bromide was absorbed as a precipitate of silver bromide and bromate was unretained when the nearly neutral sample passed a combination of Ag and H cartridges.
View Article and Find Full Text PDFUnder acidic conditions tellurium(IV) formed a complex with ammonium pyrrolidine dithiocarbamate (APDC). The tellurium(IV) complex was completely retained on a non-polar Isolute silica-based octadecyl (C(18)) sorbent-containing solid-phase extraction (SPE) cartridge, while the uncomplexed Te(VI) passed through the cartridge and remained as a free species in the solution. Only partial Te(IV) was retained on the SPE cartridge for samples without addition of APDC.
View Article and Find Full Text PDFA novel and simple method for inorganic antimony speciation is described based on selective solid phase extraction (SPE) separation of antimony(III) and highly sensitive inductively coupled plasma mass spectrometric (ICP-MS) detection of total antimony and antimony(V) in the aqueous phase of the sample. Non-polar SPE cartridges, such as the Isolute silica-based octyl (C8) sorbent-containing cartridge, selectively retained the Sb(III) complex with ammonium pyrrolidine dithiocarbamate (APDC), while the uncomplexed Sb(V) remained as a free species in the solution and passed through the cartridge. The Sb(III) concentration was calculated as the difference between total antimony and Sb(V) concentrations.
View Article and Find Full Text PDF