Publications by authors named "Chungen Qian"

Article Synopsis
  • * A new monoclonal chimeric IgG1 antibody, called 4G6, has been developed from a murine-specific antibody for the inner lipoyl domain of PDC-E2 and can recognize all AMA epitopes used in current diagnostic tests.
  • * The 4G6 antibody demonstrates strong binding affinity, making it a reliable quantitative reference for AMA testing and a promising standard for international use.
View Article and Find Full Text PDF

Hydroxycarboxylic acid receptor 3 (HCAR3), a class A G-protein-coupled receptor, is an important cellular energy metabolism sensor with a key role in the regulation of lipolysis in humans. HCAR3 is deeply involved in many physiological processes and serves as a valuable target for the treatment of metabolic diseases, tumors, and immune diseases. Here, we report four cryoelectron microscopy (cryo-EM) structures of human HCAR3-Gi1 complexes with or without agonists: the endogenous ligand 3-hydroxyoctanoic acid, the drug niacin, the highly subtype-specific agonist compound 5c (4-(n-propyl)amino-3-nitrobenzoic acid), and the apo form.

View Article and Find Full Text PDF

Exosomes, extracellular vesicles carrying a cargo rich in various non-coding RNAs (ncRNAs), have emerged as crucial mediators of intercellular communication. Their stability, abundance, and specificity make exosomal ncRNAs promising candidates for biomarker discovery. The discovery of exosomal ncRNAs has unveiled a novel avenue for the exploration of biomarkers in tumor early diagnosis.

View Article and Find Full Text PDF

For every epidemic outbreak, the prevention and treatments in resource-limited areas are always out of reach. Critical to this is that high accuracy, stability, and more comprehensive analytical techniques always rely on expensive and bulky instruments and large laboratories. Here, a fully integrated and high-throughput microfluidic system is proposed for ultra-multiple point-of-care immunoassay, termed Dac system.

View Article and Find Full Text PDF

Point of care testing (POCT) of nucleic acids holds significant importance in the realm of infectious disease prevention and control, as well as the advancement of personalized precision medicine. Nevertheless, conventional nucleic acid testing methods continue to face challenges such as prolonged detection times and dependence on extensive specialized equipment and personnel, rendering them unsuitable for point of care applications. Here, we proposed an innovative active centrifugal microfluidic system (ACMS) for automatic nucleic acid extraction, encompassing modules for active valve control and magnetic control.

View Article and Find Full Text PDF

Immunoassays serve as powerful diagnostic tools for early disease screening, process monitoring, and precision treatment. However, the current methods are limited by high costs, prolonged processing times (>2 h), and operational complexities that hinder their widespread application in point-of-care testing. Here, we propose a novel centrifugo-neumatic eciprocating flowing coupled with spatial onfinement strategy, termed , for ultrafast multiplexed immunoassay of pathogens on a centrifugal icrofluidic platform.

View Article and Find Full Text PDF

Point-of-care testing (POCT) is experiencing a groundbreaking transformation with microfluidic chips, which offer precise fluid control and manipulation at the microscale. Nevertheless, chip design or operation for existing platforms is rather cumbersome, with some even heavily depending on external drivers or devices, impeding their broader utilization. This study develops a unique programmable gravity self-driven microfluidic chip (PGSMC) capable of simultaneous multi-reagent sequential release, multi-target analysis, and multi-chip operation.

View Article and Find Full Text PDF

Respiratory tract infections are associated with the most common diseases transmitted among people and remain a huge threat to global public health. Rapid and sensitive diagnosis of causative agents is critical for timely treatment and disease control. Here, we developed a novel method based on recombinase polymerase amplification (RPA) combined with CRISPR-Cas12a to detect three viral pathogens, including SARS-CoV-2, influenza A, and influenza B, which cause similar symptom complexes of flu cold in the respiratory tract.

View Article and Find Full Text PDF

There remains an unmet need for a fully integrated microfluidic platform that can automatically perform multistep and multireagent immunoassays. Here, we proposed a novel online dual-active valve-based centrifugal microfluidic chip, termed DAVM, for fully automatic point-of-care immunoassay. Practically, the puncture valve, one of the dual active valves, is capable of achieving precise, on-demand, sequential release of prestored reagents, while the other valve-reversible active valve enables controlled retention and drainage of the reaction solutions.

View Article and Find Full Text PDF

Background: To date, several types of laboratory tests for coronavirus disease 2019 (COVID-19) diagnosis have been developed. However, the clinical importance of serum severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) nucleocapsid antigen (N-Ag) remains to be fully elucidated. In this study, we sought to investigate the value of serum SARS-CoV-2 N-Ag for COVID-19 diagnosis and to analyze N-Ag characteristics in COVID-19 individuals.

View Article and Find Full Text PDF

This paper proposed a hand-powered centrifugal micropipette-tip strategy, termed HCM, for all-in-one immunoassay combined with a distance-based readout for portable quantitative detection of SARS-CoV-2. The target SARS-CoV-2 virus antigen triggers the binding of multiple monoclonal antibody-coated red latex nanobeads, forming larger complexes. Following incubation and centrifugation, the formed aggregated complexes settle at the bottom of the tip, while free red nanobeads remain suspended in the solution.

View Article and Find Full Text PDF

The purpose of this study is to investigate the production of both severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2)-specific antibodies and autoantibodies in serum following the third booster vaccination of the inactivated COVID-19 vaccine, and to study the effect of B cell subsets with CD27 and CD38 phenotypes in peripheral blood on antibody production. Routine blood indexes, SARS-CoV-2 antibodies, platelet factor 4 and seven antiphospholipid antibodies were detected both before and 2 months after vaccination in the medical staff of the Zhongnan Hospital of Wuhan University. Peripheral blood B cell subtypes were detected before vaccination.

View Article and Find Full Text PDF

We present a case of recurrent autoimmune hypoglycemia induced by non-hypoglycemic agents. We review reported cases of autoimmune hypoglycemia related to non-hypoglycemic agents, and discuss the effects of different detection methods for insulin autoantibodies on the results obtained. We aim to provide information for clinicians and a warning for medication usage.

View Article and Find Full Text PDF

Background: We compared the temporal changes of immunoglobulin M (IgM), IgG, and IgA antibodies against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) nucleoprotein (N), spike 1 subunit (S1), and receptor-binding domain (RBD), and neutralizing antibodies (NAbs) against SARS-CoV-2 in patients with coronavirus disease 2019 (COVID-19) to understand the humoral immunity in COVID-19 patients for developing drugs and vaccines for COVID-19.

Methods: A total of five confirmed COVID-19 cases in Nissan Tamagawa Hospital in early August 2020 were recruited in this study. Using a fully automated chemiluminescence immunoassay analyzer, we measured the levels of IgG, IgA, and IgM against SARS-CoV-2 N, S1, and RBD and NAbs against SARS-CoV-2 in COVID-19 patients' sera acquired multiple times in individuals from 0 to 76 days after symptom onset.

View Article and Find Full Text PDF

Early diagnosis of Epstein-Barr virus (EBV) can reduce the risk of major illnesses. Disadvantages of EBV antibody detection methods that are commonly used clinically include lengthy assay time, need for a lot of reagent, and low efficiency. Compared with traditional detection methods, microfluidics technology offers high throughput, low reagent consumption, less bio-contamination, and a higher degree of automation.

View Article and Find Full Text PDF

Numerous studies have suggested that the titers of antibodies against SARS-CoV-2 are associated with the COVID-19 severity, however, the types of antibodies associated with the disease maximum severity and the timing at which the associations are best observed, especially within one week after symptom onset, remain controversial. We attempted to elucidate the antibody responses against SARS-CoV-2 that are associated with the maximum severity of COVID-19 in the early phase of the disease, and to investigate whether antibody testing might contribute to prediction of the disease maximum severity in COVID-19 patients. We classified the patients into four groups according to the disease maximum severity (severity group 1 (did not require oxygen supplementation), severity group 2a (required oxygen supplementation at low flow rates), severity group 2b (required oxygen supplementation at relatively high flow rates), and severity group 3 (required mechanical ventilatory support)), and serially measured the titers of IgM, IgG, and IgA against the nucleocapsid protein, spike protein, and receptor-binding domain of SARS-CoV-2 until day 12 after symptom onset.

View Article and Find Full Text PDF

Several types of laboratory tests for COVID-19 have been established to date; however, the clinical significance of the serum SARS-CoV-2 nucleocapsid (N) antigen levels remains to be fully elucidated. In the present study, we attempted to elucidate the usefulness and clinical significance of the serum N antigen levels. We measured the serum N antigen levels in 391 serum samples collected from symptomatic patients with a confirmed diagnosis of COVID-19 and 96 serum samples collected from patients with non-COVID-19, using a fully automated chemiluminescence immunoassay analyzer.

View Article and Find Full Text PDF

To better understand the immune responses to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection in individuals with COVID-19, it is important to investigate the kinetics of the antibody responses and their associations with the clinical course in different populations, since there seem to be considerable differences between Western and Asian populations in the clinical features and spread of COVID-19. In this study, we serially measured the serum titers of IgM, IgG and IgA antibodies generated against the nucleocapsid protein (NCP), S1 subunit of the spike protein (S1), and receptor-binding domain in the S1 subunit (RBD) of SARS-CoV-2 in Japanese individuals with COVID-19. Among the IgM, IgG, and IgA antibodies, IgA antibodies against all of the aforementioned viral proteins were the first to appear after the infection, and IgG and/or IgA seroconversion often preceded IgM seroconversion.

View Article and Find Full Text PDF

Background: Tokyo, the capital of Japan, is a densely populated city of >13 million people, so the population is at high risk of epidemic severe acute respiratory coronavirus 2 (SARS-CoV-2) infection. A serologic survey of anti-SARS-CoV-2 IgG would provide valuable data for assessing the city's SARS-CoV-2 infection status. Therefore, this cross-sectional study estimated the anti-SARS-CoV-2 IgG seroprevalence in Tokyo.

View Article and Find Full Text PDF

Continuous glucose monitors (CGMs) for the non-invasive monitoring of diabetes are constantly being developed and improved. Although there are multiple biosensing platforms for monitoring glucose available on the market, there is still a strong need to enhance their precision, repeatability, wearability, and accessibility to end-users. Biosensing technologies are being increasingly explored that use different bodily fluids such as sweat and tear fluid, etc.

View Article and Find Full Text PDF

We collected blood from coronavirus disease 2019 (COVID-19) convalescent individuals and investigated SARS-CoV-2-specific humoral and cellular immunity in these discharged patients. Follow-up analysis in a cohort of 171 patients at 4-11 months after the onset revealed high levels of IgG antibodies. A total of 78.

View Article and Find Full Text PDF

PCR methods are presently the standard for the diagnosis of Coronavirus disease 2019 (COVID-19), but additional methodologies are needed to complement PCR methods, which have some limitations. Here, we validated and investigated the usefulness of measuring serum antibodies against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) using the iFlash3000 CLIA analyzer. We measured IgM and IgG titers against SARS-CoV-2 in sera collected from 26 PCR-positive COVID-19 patients, 53 COVID-19-suspected but PCR-negative patients, and 20 and 100 randomly selected non-COVID-19 patients who visited our hospital in 2020 and 2017, respectively.

View Article and Find Full Text PDF

The accurate and prompt diagnosis of SARS-CoV-2 infection is required for the control and treatment of the coronavirus infection disease 2019 (COVID-19). In this study, we aimed to investigate the time courses of the anti-severe acute corona respiratory syndrome coronavirus 2 (SARS-CoV-2) IgM and IgG titers and to evaluate the sensitivity and specificity of such tests according to the specific day after the onset of COVID-19 among a patient population in Japan. We measured the titers of SARS-CoV-2 IgM and IgG in sera from 105 subjects, including 26 symptomatic COVID-19 patients, using chemiluminescent immunoassay (CLIA) methods utilizing magnetic beads coated with SARS-CoV-2 nucleocapsid protein and spike protein.

View Article and Find Full Text PDF