Background: Hair transplantation (HT) has been reported to be effective for the treatment of female-pattern hair loss (FPHL). Few studies have investigated HT in FPHL.
Objective: To evaluate the clinical features of FPHL treated with HT and analyze the real-world results of HT.
While many gene expression studies have focused on male pattern baldness (MPB), few studies have investigated the genetic differences between bald and non-bald hair follicles in female pattern hair loss (FPHL). This study aimed to identify molecular biomarkers associated with FPHL through genetic analysis of paired bald and non-bald hair follicles from 18 FPHL patients, using next-generation sequencing (NGS) techniques. RNA transcriptome analysis was performed to identify differentially expressed genes (DEGs) between bald and non-bald hair follicles in FPHL.
View Article and Find Full Text PDFThe rate of preterm birth is increasing worldwide and preterm infants are susceptible to oral health problems. Hence, this study aimed to investigate the effect of premature birth on dietary and oral characteristics as well as dental treatment experiences of preterm infants using a nationwide cohort study. Data was retrospectively analyzed from National Health Screening Program for Infants and Children (NHSIC) of the National Health Insurance Service of Korea.
View Article and Find Full Text PDFAlthough drug-eluting stents (DES) have become the mainstay of percutaneous coronary intervention, late and very late stent thrombosis remains a concern. Drug-coated balloons (DCB) have the advantage of preserving the anti-restenotic benefits of DES while minimizing potential long-term safety concerns. Currently the two methods to ensure successful DCB treatment of a stenotic lesion are angiography or physiology-guided DCB application.
View Article and Find Full Text PDFObjectives: This study investigated the sex difference of long-term cardiovascular outcomes on coronary flow reserve (CFR) and index of microcirculatory resistance (IMR) in patients with deferred coronary artery lesions.
Background: Coronary microvascular dysfunction is associated with poorer long-term outcomes. It can be assessed by CFR and the IMR.
Int J Cardiovasc Imaging
February 2020
Paclitaxel-coated balloon (PCB) treatment guided by fractional flow reserve (FFR) is safe and effective for de novo coronary lesions. It is unknown whether the instantaneous wave-free ratio (iFR), an alternative measure that does not require the administration of adenosine, will offer benefits similar to those of FFR in de novo lesion treatment with PCB. Baseline, post-balloon and 9-month angiographical parameters were obtained from 116 lesions of 104 patients.
View Article and Find Full Text PDFLesion characteristics determined by angiography after balloon angioplasty such as residual dimeter stenosis (DS) or dissection type has been used to determine the treatment method of drug-coated balloon (DCB) or metal stent for de novo coronary lesions. The aim of this study is to identify angiographic and functional mismatch using residual DS, dissection type and fractional flow reserve (FFR). Baseline and post-balloon parameters were obtained from 151 patients with 167 lesions.
View Article and Find Full Text PDFObjective: The vasoconstrictor component of atherothrombotic culprit lesions in ST-elevation myocardial infarction (STEMI) patients has not been fully investigated. This study was aimed at assessing the vasoconstrictor component of atherothrombotic culprit lesions in patients with STEMI receiving primary percutaneous coronary intervention (PCI).
Methods: A group of 100 patients with STEMI were enrolled prospectively.
Background: In patients with high bleeding risk, percutaneous coronary intervention is still debated. This study compared 9-month angiographic and physiologic results in patients with high bleeding risk and de novo coronary lesions treated with either paclitaxel-coated balloon (PCB) or bare-metal stent (BMS).
Patients And Methods: A total of 40 patients (40 lesions) with high bleeding risk who underwent successful balloon angioplasty with fractional flow reserve (FFR) after balloon angioplasty more than 0.
Background: Exercise electrocardiography (ECG) is frequently used as a diagnostic measure in patients with suspected coronary artery disease (CAD). However, it has low sensitivity for the detection of CAD. Magnetocardiography (MCG) has been proposed as an alternative tool to accurately diagnose CAD.
View Article and Find Full Text PDFThis study aimed to assess the healing response, as evidenced through temporal morphological and functional changes, following paclitaxel-coated balloon (PCB) treatment of de novo coronary lesions. This retrospective, observational study, included patients with significant de novo coronary lesions who were treated with PCB and had serial angiographic, intravascular ultrasound virtual histology (IVUS-VH), fractional flow reserve (FFR) measurements, and optical coherence tomography (OCT) performed before balloon angioplasty (BA), after BA, and at 9-month follow-up. A total of 20 patients (21 lesions) were included in this study.
View Article and Find Full Text PDFWhile fractional flow reserve (FFR) is a good diagnostic index to assess the myocardial ischemia, coronary flow reserve (CFR) and the index of microcirculatory resistance (IMR) can be used to address microvascular status without any significant epicardial disease. The independent predictors for FFR and IMR are totally different and acts differently on the macro- and micro-vascular dysfunction. In high FFR patients, low CFR and high IMR which indicates the presence of overt microvascular disease demonstrated poor prognosis.
View Article and Find Full Text PDFThe POST (the effects of postconditioning on myocardial reperfusion in patients with ST-Segment elevation myocardial infarction) study showed that ischemic postconditioning did not improve myocardial reperfusion in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (PCI). However, it has not been determined whether postconditioning is effective in women. This study sought to evaluate the impact of sex differences on ischemic postconditioning during the primary PCI.
View Article and Find Full Text PDFCoronary computed tomography angiography (CCTA)-derived fractional flow reserve from computed tomography (CT-FFR) may provide better diagnostic performance over CCTA alone, but the complexity of its method limits the use in clinical environment. The aim of the present study is to validate a newly developed vessel-length based computational fluid dynamics scheme for the computation of FFR based on CCTA data, compare them with invasively measured FFR, and evaluate its diagnostic performance with that of CCTA. One hundred seventeen patients from 4 medical institutions who had clinically indicated invasive coronary angiography for suspected coronary artery disease (CAD) were enrolled.
View Article and Find Full Text PDFObjective: As the stenotic severity of a patient increases, fractional flow reserve (FFR) decreases, whereas the maximum wall shear stress (WSSmax) increases. However, the way in which these values can change according to stenotic severity has not previously been investigated. The aim of this study is to devise a virtual stenosis model to investigate variations in the coronary hemodynamic parameters of patients according to stenotic severity.
View Article and Find Full Text PDFFractional flow reserve (FFR) is an index for identifying functionally significant stenotic lesions. A FFR value of ≤0.75 is considered clinically significant and indicative of physiological ischemia.
View Article and Find Full Text PDFBackgrounds: Edge dissections after intervention have been studied with imaging techniques, however, functional assessment has not been studied yet. We investigated the relationship between fractional flow reserve (FFR) and the angiographic type of stent edge dissections and tried to assess the use of FFR-guided management for edge dissection.
Methods: 51 edge dissections assessed by FFR were included in this prospective observational study.
To overcome the complications due to the use of noncompliant large diameter conventional chest drain devices, a flexible small diameter chest drain device was designed and simulated based on computational fluid dynamics (CFD) techniques. It was clearly shown that the pressure drop and velocity increase of the most distal drainage holes, which are located near the suction end, are dominant over other drainage holes. A conventional chest drain device with circular side holes showed higher mass flow rate due to larger cross sectional area.
View Article and Find Full Text PDF