The flow and leakage characteristics of the air-curtain fume hood under high temperature operation (between 100°C and 250°C) were studied. Laser-assisted flow visualization technique was used to reveal the hot plume movements in the cabinet and the critical conditions for the hood-top leakage. The sulfur hexafluoride tracer-gas concentration test method was employed to examine the containment spillages from the sash opening and the hood top.

View Article and Find Full Text PDF

A wake-controlled exterior hood was developed to overcome the negative influence of cross draft on an exterior hood and avoid the operation inconvenience caused by the enclosure of an airflow capture booth. This new type of local exterior hood used the hood suction flow to stabilize the dynamic vortex shedding that was induced when a crossflow passed over a blockage plate, and therefore formed a hydrodynamics-stabilized local isolation area for efficient removing of the contaminant. The development process was performed in a test section of an open-circuit wind tunnel.

View Article and Find Full Text PDF

Effects of flange size on the flow patterns of an exterior circular hood subject to the influence of various uniform cross drafts were studied in an apparatus consisting of hood-model/wind-tunnel assembly. The cross draft to suction velocity ratio covered the range from 0.056 to 0.