Purpose: We investigated the vertical implantation of a toric implantable collamer lens (ICL) and compared the rotational stability with that of horizontal implantation.
Methods: This matched comparative study retrospectively reviewed and analyzed data from patients who underwent ICL implantation from 2003-2022 by 1:1 matching vertical and horizontal (V and H toric groups, respectively) implantation patients according to preoperative astigmatism, spherical equivalent, sulcus-to-sulcus, anterior chamber depth, and ICL size. Visual acuity, manifest refraction, vaulting, and rotation were measured 3 months postoperatively.
Purpose: To investigate the safety and efficacy of a new micro-controlled radiofrequency device for treatment of conjunctivochalasis (Cch).
Methods: Data of 127 patients (230 eyes) who underwent ophthalmic radiofrequency treatment for Cch from January 2020 to June 2023 were analyzed retrospectively. Cch coagulation was performed with a radiofrequency electrode tip (OcuRF®, Ilooda, Korea) and a high-frequency radio-wave electric unit (0.
Importance: Taking ω-3 supplements has been associated with a reduction in symptoms of dry eye disease (DED) associated with meibomian gland dysfunction (MGD). However, a recent relatively large clinical trial concluded that treating DED with ω-3 consumption was ineffective, potentially warranting additional investigations.
Objectives: To investigate the effect of re-esterified triglyceride (rTG) ω-3 fatty acid supplementation on DED associated with MGD.
Objective: To evaluate the effects of rigid corneal lenses (RCL) in patients with keratoconus, based on eccentricity.
Methods: Eighty-four eyes from 84 patients were included in this retrospective comparative study. Based on the median value of eccentricity difference between the cornea and back surface of the RCL, the patients were divided into groups 1 (<0.
Purpose: To investigate the clinical outcomes of new hydrophobic trifocal intraocular lens with hydroxyethyl methacrylate in the Korean population.
Methods: This prospective, multicenter, and observational study evaluated the clinical outcomes of 80 eyes of 40 patients with age-related cataract underwent cataract surgery using CNWT (Clareon PanOptix). Assessment included monocular and binocular uncorrected distance visual acuity, corrected distance visual acuity, uncorrected intermediate visual acuity (at 60cm), near visual acuity (at 40 and 33 cm), uncorrected defocus curves, questionnaires evaluating photic phenomena, spectacle independence, and spectacle free satisfaction.
Purpose: The purpose of this study was to investigate the efficacy and indications of using dried gamma ray-sterilized amniotic membrane (AM) transplantation with bandage contact lenses for the in-office sutureless treatment of various ocular surface diseases.
Methods: This study retrospectively included 56 eyes of 52 patients with various ocular surface diseases treated with sutureless dehydrated AM-assisted therapeutic contact lenses. The patients were followed up and assessed 1, 2, and 4 weeks after the treatment, and the therapeutic contact lenses were removed after 1 or 2 weeks.
Purpose: This study assessed post-market clinical outcomes of the Clareon monofocal intraocular lens (IOL) preloaded in the AutonoMe Delivery System in a real-world setting of Korean patients.
Methods: This prospective, multicenter, single-arm study in Korea was conducted from July 2020 to December 2021. Patients were ≥20 years old with unilateral or bilateral cataracts who received Clareon IOLs (CNA0T0) preloaded in an automated injector system.
Background: To evaluate the efficacy of 1% and 2% rebamipide clear solution in the treatment of dry eye disease (DED).
Methods: Two hundred twenty patients with DED were randomly assigned to one of three groups: the 1% rebamipide, 2% rebamipide, or placebo (eye drops containing the same ingredients, except for the active components). Each eye drop was instilled four times daily for 12 weeks.
We evaluated the influence of intraocular lens (IOL) opacification on the optical performance of explanted hydrophilic acrylic IOLs. We performed a laboratory analysis of 32 Lentis LS-502-1 (Oculentis GmbH, Berlin, Germany) IOLs, explanted due to opacification, in comparison with six clear unused samples of the same IOL model. Using an optical bench setup, we obtained modulation transfer function (MTF), Strehl ratio, two-dimensional MTF, and United States Air Force (USAF) chart images.
View Article and Find Full Text PDFPurpose: To identify specific dry eye disease (DED) tear biomarker(s) using tear proteomic analysis, clinical parameters, and their correlations before and after DED treatment.
Methods: A prospective, double-blinded, national multicenter clinical study was performed using data from 80 DED patients. The patients were treated with 0.
Background: To compare the clinical outcomes of bilateral implantation of enhanced intermediate function intraocular lenses (IOLs) and standard monofocal IOLs.
Methods: In this prospective, randomized, comparative controlled study, we compared the visual outcomes of patients who underwent bilateral cataract surgery at the Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, with either enhanced monofocal IOLs (Tecnis Eyhance, ICB00, Johnson and Johnson Vision Care, Inc) (Group 1) or standard monofocal IOLs (Tecnis, ZCB00, Johnson and Johnson Vision Care, Inc) (Group 2). The assessment included monocular and binocular uncorrected distance visual acuity (UDVA), uncorrected intermediate (UIVA at 60 cm) and near (UNVA at 40 cm) visual acuity, uncorrected defocus curves, contrast sensitivity testing (CST), and reading speed test using Quality of vision was evaluated using the Visual Function Questionnaire (VFQ-25).
Background: To introduce and evaluate the efficacy of a simple punctal occlusion technique for dry eye patients.
Methods: Medical records of 79 eyes from 40 patients refractory to common dry eye conservative treatment who underwent multiple high-frequency radio-wave electro-punctal occlusion were retrospectively reviewed. Pre- and post-procedural ocular surface indices (Schirmer test, tear break-up time (TBUT), and corneal staining grade (Oxford scheme)) and subjective symptom scores (including frequency of artificial tear use, interval between procedures, and total repeat time) were analyzed.
Medicine (Baltimore)
January 2023
To determine the effectiveness of conjunctivoplasty using a modified argon laser photocoagulation method on patients with conjunctivochalasis (CCh). This study included 25 cases of symptomatic inferior CCh. After staining the surface of a redundant conjunctiva using a dark-purple marker, low-energy argon laser photocoagulation (500 μm spot size for 0.
View Article and Find Full Text PDFDespite all the progress in cataract and refractive lens surgery, refractive surprise is common in clinical practice. A significant postoperative refractive error is particularly annoying - and contributes to the patient's dissatisfaction with the procedure and the surgeon - when a multifocal IOL, an EDOF-IOL or a toric IOL has been implanted. The relatively new technology of intraoperative aberrometry offers the surgeon the option to intraoperatively measure the eye and its refraction, either directly after lens extraction and/or following IOL implantation.
View Article and Find Full Text PDFHyaluronic acid (HA) and cyclosporine A (CsA) eyedrops are commonly prescribed in dry eye syndrome (DES). The effectiveness of each preparation in DES is well-known, yet the superiority of one over another has been studied little. We assessed the efficacy and tolerability of 0.
View Article and Find Full Text PDFBackground: We investigate the performance of new hydrophobic diffractive multifocal intraocular lenses (IOL) with hydroxyethyl methacrylate (HEMA) and compare their optical quality, contrast sensitivity, and subjective photic phenomena.
Methods: Medical records of patients who underwent routine simple cataract surgery and insertion of an existing multifocal IOL (TFNT, TF group) or a new multifocal IOL (CNWT, CN group) were retrospectively reviewed. Clinical data was collected 2 months postoperatively and included optical quality analysis system (OQAS) indices, contrast sensitivity, and subjective degrees of photic phenomena.
Purpose: The purpose of this study was to introduce the initial experience in the use of topical pegylated interferon alpha 2a (PegIFN-α-2a) for ocular surface squamous neoplasia (OSSN).
Methods: A retrospective medical record review of 8 eyes of 8 patients diagnosed with OSSN and treated with PegIFN-α-2a was performed. All cases were diagnosed of noninvasive OSSN both clinically and histologically.
Visual impairment is a global health problem that leads to poor quality of life. The aim of the study was to examine the dose-response relationship between alcohol consumption and incident visual impairment (VI). This longitudinal cohort study consisted of 287,352 Korean adults who attended health screenings between March 2011 and December 2017 and were followed for up to 8.
View Article and Find Full Text PDFPurpose: To compare the light transmittance property of seven currently used intraocular lens (IOL) models by spectrophotometer data.
Methods: Light transmission spectra of seven IOL models were assessed with a spectrophotometer. The transmittance properties were analyzed in 1 nm units from 350 nm wavelength to 800 nm.
: This study sought to investigate the natural course, the chronicity and recurrence rate, and the risk factors of chronic and recurrent herpes zoster ophthalmicus (HZO). We also evaluated the effects of long-term treatment for HZO. : Patients diagnosed and treated for HZO were included in the retrospective medical chart review.
View Article and Find Full Text PDFWe investigated longitudinal changes in the spherical equivalent refractive error (SE) in hyperopic children with or without refractive accommodative esotropia (AccET). A total of 456 patients met the inclusion criteria: 190 (41.7%) in the hyperopic control group and 266 (58.
View Article and Find Full Text PDFPurpose: To evaluate monocular and binocular visual performance and patient-reported outcomes following combined implantation of a diffractive extended depth of focus (EDoF) IOL (Carl Zeiss AT LARA 829MP) and a diffractive trifocal IOL (Carl Zeiss AT LISA tri 839MP).
Methods: This prospective study enrolled consecutive patients undergoing lens phacoemulsification of cataract and combined implantation of an EDoF IOL in the dominant eye and a trifocal IOL in the nondominant eye. Assessment included uncorrected visual acuity at near distances (UNVA), intermediate distances (UIVA), and far distances (UDVA), uncorrected defocus curve, contrast sensitivity (CS), reading speed, and patient satisfaction, evaluated six months after the surgery with the Visual Function Questionnaire (VFQ-25).