Background: An increasing amount of evidence suggests that telomere length (TL) at birth can predict lifespan and is associated with chronic diseases later in life, but newborn TL may be affected by environmental pollutants. Neonicotinoids (NEOs) are widely used worldwide, and despite an increasing number of studies showing that they may have adverse effects on birth in mammals and even humans, few studies have examined the effect of NEO exposure on newborn TLs.
Objective: To investigate the effects of prenatal exposure to NEOs and the interactions between NEOs and sampling season on newborn TL.
Tunnel magnetoresistance (TMR) can measure weak magnetic fields and has significant advantages for use in alternating current/direct current (AC/DC) leakage current sensors for power equipment; however, TMR current sensors are easily perturbed by external magnetic fields, and their measurement accuracy and measurement stability are limited in complex engineering application environments. To enhance the TMR sensor measurement performance, this paper proposes a new multi-stage TMR weak AC/DC sensor structure with high measurement sensitivity and anti-magnetic interference capability. The front-end magnetic measurement characteristics and interference immunity of the multi-stage TMR sensor are found to be closely related to the multi-stage ring size design via finite element simulation.
View Article and Find Full Text PDFBackground: Fetal growth restriction (FGR) is a major determinant of perinatal morbidity and mortality, with adverse long-term neurocognitive effects in childhood and adulthood. Prenatal exposure to environmental pollutants has been reported to be associated with FGR. Neonicotinoids (NEOs) are extensively used insecticides worldwide and are suggested to have embryonic and developmental neurotoxicity.
View Article and Find Full Text PDFThe status of zinc oxide (ZnO) arresters is directly related to the safety of power grids. However, as the service life of ZnO arresters increases, their insulation performance may decrease due to factors such as operating voltage and humidity, which can be identified through the measurement of leakage current. Tunnel magnetoresistance (TMR) sensors with high sensitivity, good temperature stability, and small size are excellent for measuring leakage current.
View Article and Find Full Text PDFEnviron Sci Pollut Res Int
December 2022
Bisphenols are endocrine disruptor chemicals that disrupt thyroid hormone homeostasis. However, evidence on the effects of bisphenol mixtures on thyroid hormones are insufficient. Therefore, the present study aimed to explore the effects of bisphenol substitutes and bisphenol mixtures on thyroid hormones during pregnancy.
View Article and Find Full Text PDFSheng Wu Yi Xue Gong Cheng Xue Za Zhi
June 2010
According to the pulse-wave theory, the authors developed a new non-invasive instrument for measuring arterial elastic function. It collects the pulse waveforms from the arteries of four limbs as well as from the radial arteries of carpus. After signal pre-processing, it calculates the arterial elastic parameters by the pre-prepared algorithm and program.
View Article and Find Full Text PDFConf Proc IEEE Eng Med Biol Soc
October 2012
For the purpose of measurement and evaluation of arterial stiffness, we design a noninvasive medical device based on the oscillometric method and the pulse wave velocity (PWV) method, and employ arterial stiffness index (ASI) and PWV as accessing parameters. The inner pressure signal of cuff on the upper arm and the pulse wave signal at the tip of finger will be sampled, and the special software can utilize these signals to calculate two accessing parameters and obtain the evaluation conclusion of arterial stiffness. The clinical experiments show that this medical device and evaluation method are effective and valuable.
View Article and Find Full Text PDFConf Proc IEEE Eng Med Biol Soc
October 2012
In this paper an advanced algorithm based on G-P algorithm is introduced to calculate the Correlative Dimension (CD) of HRV signals. Moreover, Theiler's Correction is considered to avoid the autocorrelation effect of the time serials. It will reduce the possibility to get spurious dimension.
View Article and Find Full Text PDF