The traditional nuclear pulse signal generator outputs the nuclear pulse signal of specific waveform according to the input pulse amplitude probability distribution and counting rate, following the signal output laws of radiation detector in both pulse amplitude and time interval. However, the output waveform is generally regulated by an analog circuit, with the single waveform and difficult parameter adjustment. In this study, the digital C-R and R-C filters were explored, a cascading digital C-R or R-C filter algorithm was proposed, realizing multiple pragmatic nuclear pulse signal outputs through the serial or parallel connection of multiple digital filters.

View Article and Find Full Text PDF
Article Synopsis
  • Semiconductor detectors like Si-PIN and CdTe are important for energy dispersive X-ray fluorescence measurements and were compared in terms of material properties, efficiency, and energy resolution.
  • The study examined how factors like detector thickness, X-ray energy, and circuit shaping time affect performance, including issues like incomplete hole collection causing energy spectrum differences.
  • Results showed that while both detectors are efficient below 15 keV, CdTe performs better above that energy; Si-PIN offers superior energy resolution, but implementing a DMCA reduces hole tailing effects in CdTe, enhancing its performance.