Objective: To evaluate the efficacy and safety of the through-and-through wire (TTW) technique for antegrade ureteral Double-J stent placement after failure of either antegrade or retrograde ureteral stent placement.
Method: This retrospective study analyzed the medical records of consecutive patients who underwent Double-J stent placement with the TTW technique at Asan Medical Center and Gil Medical Center between January 2016 and February 2023. Patient histories, reasons for employing the TTW technique, TTW pathways, and complications were reviewed.
To evaluate the safety and efficacy of combining EW-7197 with irreversible electroporation (IRE) for improving wound healing, 16 male Sprague-Dawley rats were randomly divided into four groups of four rats each after dorsal excisional wound induction: sham control group; oral administration of EW-7197 for 7 days group; one-time application of IRE group; and one-time application of IRE followed by oral administration of EW-7197 for 7 days group. Measurement of wound closure rate, laser Doppler scanning, histological staining (hematoxylin and eosin and Masson's trichrome), and immunohistochemical analyses (Ki-67 and α-SMA) were performed to evaluate the efficacy. Fifteen of 16 rats survived throughout the study.
View Article and Find Full Text PDFBackground And Aims: Endobiliary radiofrequency ablation (RFA) is an emerging endoscopic palliative adjunctive therapy used for the local treatment of unresectable malignant biliary obstruction (MBO). However, irregular ablation ranges caused by insufficient electrode-to-bile duct contact pose a significant obstacle. We investigated the feasibility of a self-expandable stent (SES)-based electrode with a customized RFA generator in the porcine liver and common bile duct (CBD).
View Article and Find Full Text PDFCardiovasc Intervent Radiol
July 2024
Purpose: To evaluate the safety and clinical outcome of two-session catheter-directed sclerotherapy (CDS) with 99% ethanol in patients with endometrioma.
Materials And Methods: This prospective study was approved by the institutional review board with written informed consent obtained from all participants and was registered on clinicaltrial.gov.
Prophylactic embolization is usually performed using gelatin sponge particles, which are absorbed within several weeks, for managing angiographically negative gastrointestinal bleeding. This study aimed to evaluate the safety and effectiveness of transcatheter arterial embolization (TAE) with quick-soluble gelatin sponge particles (QS-GSP) that dissolve in less than 4 h for treating angiographically negative gastrointestinal bleeding. We included ten patients (M:F = 7:3; mean age, 64.
View Article and Find Full Text PDFPurpose: The elastase-induced aneurysm (EIA) model in rabbits has been proposed for translational research; however, the adjustment of aneurysm neck size remains challenging. In this study, the technical feasibility and safety of balloon neck-plasty to create a wide-necked aneurysm in rabbit EIA model were investigated.
Methods: Male New Zealand White rabbits (N = 15) were randomly assigned to three groups: group A, EIA creation without neck-plasty; group B, neck-plasty immediately after EIA creation; group C, neck-plasty 4 weeks after EIA creation.
Purpose: To investigate elbows with primary osteoarthritis (OA) for the presence of anterior radial head subluxation.
Methods: A total of 71 patients with elbow osteoarthritis and 45 with lateral epicondylitis were initially identified. The baseline characteristics and preoperative elbow X-rays of consecutive patients that had been clinically confirmed with elbow OA or lateral epicondylitis between March 2011 and January 2020 were then retrospectively reviewed.
Knee Surg Sports Traumatol Arthrosc
December 2023
In-stent restenosis caused by tissue hyperplasia and tumor growth through the wire meshes of an implanted self-expandable metallic stent (SEMS) remains an unresolved obstacle. This study aimed to investigate the safety and efficacy of SEMS-mediated radiofrequency ablation (RFA) for treating stent-induced tissue hyperplasia in a rat gastric outlet obstruction model. The ablation zone was investigated using extracted porcine liver according to the ablation time.
View Article and Find Full Text PDFThis study aimed to investigate the efficacy of a closed-cell self-expandable metallic stent (SEMS) with or without expanded-polytetrafluoroethylene (e-PTFE)-covering membrane in a porcine iliac artery model. Twelve Yorkshire domestic pigs were divided into a bare closed-cell SEMS (B-SEMS) group (n = 6) and covered closed-cell SEMS (C-SEMS) group (n = 6). Both closed-cell SEMSs were placed in the right or left iliac artery.
View Article and Find Full Text PDFAbsorbable magnesium (Mg) stents have an attractive biocompatibility and rapid degradation rate, but their degradable behavior and efficacy in the Eustachian tube (ET) have not yet been investigated. In this study, the degradable behavior of the Mg stent in artificial nasal mucus was evaluated. The Mg stents in the porcine ET model were also investigated to evaluate their safety and efficacy.
View Article and Find Full Text PDFAs most patients with hepatocellular carcinoma (HCC) are diagnosed at the intermediate or advanced stage and are no longer eligible for curative treatment, the overall survival rate of HCC remains unsatisfactory. Locoregional interventional therapies (LITs), and immune checkpoint inhibitor (ICI)-based immunotherapy, focus on treating HCC, but the efficacy of their individual application is limited. Therefore, the purpose of this review was to discuss the biological roles of cytokines and their therapeutic potential in the combination therapy of LITs and ICI-based immunotherapy.
View Article and Find Full Text PDFBackground: Recently, a polypropylene mesh has been introduced and reported to improve clinical outcomes after superior capsular reconstruction (SCR) using a fascia lata autograft (FLA). However, mesh-related events such as a foreign body response may trigger inflammation, which might affect graft healing and remodeling.
Purpose/hypothesis: The aim was to investigate whether the healing and remodeling of an FLA were affected by the use of a mesh by comparing the signal intensity of an FLA-alone group vs an FLA + Mesh group on postoperative magnetic resonance imaging (MRI).
Background: The relatively low aqueous solubility of EW-7197 that was administered orally may have affected the desired concentration in the systemic circulation for treating peritoneal adhesion. This experimental study aimed to compare the efficacy of different routes of administering EW-7197 (2-fluoro-N-[(5-[6-methylpyridin-2-yl]-4-[(1,2,4)triazolo(1,5-a)pyridin-6-yl]-1H-imidazol-2-yl)methyl]aniline) and EW-7197·hydrobromide (HBr), with improved aqueous solubility, for inhibiting peritoneal adhesion in a rat model.
Methods: After peritoneal adhesion induction, 30 male Sprague-Dawley rats were randomly divided into 5 groups with 6 rats in each: group A, sham control; group B, orally administered 25 mg/kg of EW-7197·HBr for 7 days; group C, locally administered 25 mg/kg of EW-7197·HBr; group D, orally administered 20 mg/kg of EW-7197 for 7 days; and group E, locally administered 20 mg/kg of EW-7197.
As a non-thermal ablation method, irreversible electroporation (IRE) has been widely investigated in the treatment of prostate cancer. However, no consensus has been achieved on the optimal parameters of IRE for prostate cancer. Since high voltage is known to carry risks of muscle contraction and patient discomfort, it is crucial to identify the minimum but effective and safer applied voltage to inhibit tumor growth.
View Article and Find Full Text PDFKnee Surg Sports Traumatol Arthrosc
July 2023
Purpose: To compare the absorbable and nonabsorbable suture knots on the tendon on bone-to-tendon healing during the early phase in a rat rotator cuff tear (RCT) model.
Methods: Fifty-two male Sprague-Dawley rats (10 weeks old; mean weight, 380 g) were used in this study, and 51 of them were randomly assigned into three groups: absorbable suture group (ASG, n = 22), nonabsorbable suture group (NSG, n = 22), and sham surgery group (SSG, n = 7), and the remaining rat was used to take surgical pictures. Bilateral supraspinatus tendon tears were created and repaired immediately in ASG and NSG.
Irreversible electroporation (IRE) has been investigated in the alimentary tract; however, the lack of dedicated electrodes and insufficient tissue responses made its application limited. The aim of this study was to investigate the efficacy and safety of image-guided stent-directed IRE in the rat esophagus. The bipolar self-expandable electrode (SE) was developed using the braiding technique.
View Article and Find Full Text PDFSeveral investigations on the feasibility of stent placement into the Eustachian tube (ET) are being conducted. However, stents optimized for the anatomical structure of the ET have not yet been developed. In this study, the efficacy and safety of a self-expandable metallic stent (SEMS) optimized for porcine ET morphology was investigated.
View Article and Find Full Text PDFEndoluminal radiofrequency (RF) ablation has been widely used as a safe and effective treatment for Barrett's esophagus. However, inadequate RF ablation may occur due to insufficient contact between the electrode and target tissues. Herein, a stent-based monopolar RF electrode (SE) was developed to evenly deliver RF energy to the inner wall of the rat esophagus.
View Article and Find Full Text PDFConventional irreversible electroporation (IRE) with low-frequency pulsed electric field (LF-PEF) is used to induce cell death; however, it has several disadvantages including a long procedure time and severe muscle contraction due to high-voltage electric field. This study investigates a novel IRE protocol with high-frequency pulsed electric field (HF-PEF) of 500 Hz repetition to ablate the prostate tissue in beagles for treatment of prostate cancer. A finite element analysis was performed to validate optimal electrical field strength for the procedure.
View Article and Find Full Text PDFStent-grafts composed of expanded polytetrafluoroethylene (e-PTFE), polyethylene terephthalate (PET) and polyurethane (PU) are characterized by poor endothelialization, high modulus, and low compliance, leading to thrombosis and intimal hyperplasia. A composite synthetic/natural matrix is considered a promising alternative to conventional synthetic stent-grafts. This study aimed to investigate the efficacy of thermoplastic polyurethane (TPU) and gelatin (GL) blended nanofibers (NFs) covered stent-graft in the porcine iliac artery.
View Article and Find Full Text PDFKnee Surg Sports Traumatol Arthrosc
May 2023
Purpose: Superior capsular reconstruction (SCR) using fascia lata autograft has been performed for irreparable rotator cuff tear recently. The signal-to-noise quotient (SNQ) of the graft on magnetic resonance imaging (MRI) may reflect the degree of graft maturity and healing. However, how SNQ changes with graft remodelling and time and whether this change correlates with postoperative clinical outcomes after SCR remain unknown.
View Article and Find Full Text PDFPurpose: To investigate the clinical safety and efficacy of computed tomography (CT)-guided iodine-125 (I) brachytherapy as a salvage treatment for esophageal cancer with locoregional lymph node recurrence (LNR).
Materials And Methods: This retrospective study included patients with esophageal cancer who developed locoregional LNR after initial curative resection followed by CT-guided I brachytherapy as a salvage treatment (January 2014 to January 2020). Local tumor progression-free survival (LTPFS) was assessed using Response Evaluation Criteria in Solid Tumors, v1.
Objectives: To investigate the efficacy and safety of dicycloplatin as chemotherapeutic regimen in transcatheter arterial chemoembolization (TACE) for hepatocellular carcinoma (HCC).
Methods: In this randomized, open-label, phase II trial, patients with unresectable HCC who were TACE treatment-naïve or experienced recurrence after surgical resection or ablation were enrolled at 7 centers in China from March 2019 to November 2019. Participants were randomly assigned (1:1:1) to receive TACE with chemotherapeutic regimen of dicycloplatin alone (group A1), dicycloplatin plus epirubicin (group A2), or epirubicin alone (group B).