Due to the change in the structure of the proximal femur and acetabulum in patients with developmental dysplasia of the hip, total hip arthroplasty (THA) was difficult to perform for surgeons. To elevate the acetabular coverage rate, we developed a technique in the use of a patient-specific instrumentation (PSI) graft in patients with developmental dysplasia of hip (DDH) undergoing surgery. This study aims to evaluate the peri-operative outcomes of THA with PSI graft in patients with DDH.
View Article and Find Full Text PDFBackground: The TomoFix plate has been extensively used in high tibial osteotomy surgery to stabilize the distracted tibial bones. However, distal pain related to plate irritation was considered one of the most relevant complications for this fixation device. This study aimed to correlate reports of distal pain with the profiles of the distracted tibia and initial plate and plate contour.
View Article and Find Full Text PDFComput Methods Biomech Biomed Engin
September 2020
Tibial condylar valgus osteotomy (TCVO) is a type of open wedge high tibial osteotomy for correcting intra-articular deformities of medial knee osteoarthritis. However, there are no implant design and related biomechanical investigations specifically for TCVO. This study aims to investigate the effects of the proximal screw direction and plate profile on the biomechanical behaviors of the TCVO construct.
View Article and Find Full Text PDFPurpose: High tibial osteotomy (HTO) has been adopted as an effective surgery for medial degeneration of the osteoarthritis (OA) knee. However, satisfactory outcomes necessitate the precise creation and distraction of osteotomized wedges and the use of intraoperative X-ray images to continually monitor the wedge-related manipulation. Thus HTO is highly technique-demanding and has a high radiation exposure.
View Article and Find Full Text PDFSeveral plate systems for high tibial osteotomy (HTO) have been developed to stabilize the opening wedge of an osteotomized tibia. Among them, the TomoFix system, having a quasi-straight and T-shaped design, has been widely adopted in the literature. However, this system is implemented by inserting a lag (i.
View Article and Find Full Text PDFBackground: High tibial osteotomy (HTO) with a medially opening wedge has been used to treat osteoarthritic knees. However, the osteotomized tibia becomes a highly unstable structure and necessitates the use of plate and screws to stabilize the medial opening and enhance bone healing. A T-shaped plate (e.
View Article and Find Full Text PDFComput Methods Biomech Biomed Engin
January 2016
Medial open high tibial osteotomy (HTO) has been used to treat osteoarthritis of the medial compartment of the knee. However, weaker plate strength, unstable plate/screw junction and improper surgery technique are highly related to the HTO outcomes. Two π-shape plates were designed and eight variations (two supporting area × four locking stiffness) were compared by finite-element method.
View Article and Find Full Text PDFBackground: Some nonstemmed hip systems have been developed to avoid stress shielding and aseptic loosening, which are major drawbacks of stemmed hip arthroplasty. Without the stem, the cup over the femoral head can be stabilized by anatomic fitness of the cup interior and mechanical fixation of the auxiliary screws.
Methods: Using finite-element method, neck-shaped systems with two bone-cup fitness situations and four types of screw breakages are systematically investigated to evaluate their biomechanical effects on construct performances.
BMC Musculoskelet Disord
March 2013
Background: High tibial osteotomy (HTO) with a medial opening wedge has been used to treat medial compartment osteoarthritis. However, this makes the proximal tibia a highly unstable structure and causes plate and screws to be the potentials sources for mechanical failure. Consequently, proper design and use of the fixation device are essential to the HTO especially for overweight or full weight-bearing patients.
View Article and Find Full Text PDF