Purpose: In the Emergency Departments (ED) the current triage systems that are been implemented are based completely on medical education and the perception of each health professional who is in charge. On the other hand, cutting-edge technology, Artificial Intelligence (AI) can be incorporated into healthcare systems, supporting the healthcare professionals' decisions, and augmenting the performance of triage systems. The aim of the study is to investigate the efficiency of AI to support triage in ED.
View Article and Find Full Text PDFObjective: The F+10 method for diuretic renography (diuretics given 10 min after the radiopharmaceutical) could be a time-conserving method. This method involves a 30-min dynamic acquisition where diuretics are administered only when necessary by the Nuclear Medicine technologist performing the examination. The purpose of this study was to assess the method's performance and to discover the optimal threshold of residual activity for a diuretic administration 7 min into the F+10 renography by reprocessing raw data from prior performed examinations with 20-min acquisitions without diuretics.
View Article and Find Full Text PDFWe report a case of a transient focal MIBI uptake in the late, 90 minutes postinjection phase of a parathyroid scintigraphy in which SPECT/CT imaging proved valuable in delineating the nature of this incidental finding.
View Article and Find Full Text PDFIn multimodality imaging, CT-derived transmission maps are used for attenuation correction (AC) of SPET or PET data. Regarding SPET myocardial perfusion imaging (MPI), however, the bene����t of CT-based AC (CT-AC) has been questioned. Although most attenuation-related artifacts are removed by this technique, new false defects may appear while some true perfusion abnormalities may be masked.
View Article and Find Full Text PDFObjective: Previous studies indicate that the quality of single photon emission tomography/computed tomography (SPET/CT) myocardial perfusion imaging (MPI) is degraded by even mild transmission-emission misregistrations. The purpose of the current study was to investigate the impact of SPET/CT misalignment on the interpretation of MPI and examine the value of a commercial software application for registration correction.
Subjects And Methods: A total of 255 technetium-99m ((99m)Tc)-tetrofosmin stress/rest MPI examinations in 150 patients were reviewed for SPET/CT misalignment.
Ann Nucl Med
August 2015
Objective: Estimation of myocardial blood flow (MBF) and coronary flow reserve (CFR) by SPECT myocardial perfusion imaging (MPI) remains challenging. Our aim was to approximate MBF and CFR by quantifying the absolute Tc-99m tetrofosmin retention in the myocardium via gated-SPECT/CT MPI.
Methods: Tracer retention was calculated on the basis of the microsphere kinetic model and served as an index of MBF at stress and rest (sMBFi, rMBFi).
Background: Previous studies advocate the use of attenuation correction in myocardial perfusion scintigraphy (MPS) for patient risk stratification.
Methods: Six-hundred and thirty-seven unselected patients underwent Tl-201 MPS by a hybrid SPECT/CT system. Attenuation-corrected (AC) and non-corrected (NAC) images were interpreted blindly and summed stress scores (SSS) were calculated.
Introduction: Resistance to chemotherapy poses a major problem in cancer patients. Although of multifactorial origin, some of the implicated mechanisms also interfere with (99m)Tc-MIBI uptake and retention in cancer cells. The aim of the current study was to investigate the prognostic value of baseline (99m)Tc-MIBI imaging in lymphoma.
View Article and Find Full Text PDFAnn Nucl Med
November 2010
Objective: Previous studies have demonstrated the feasibility of targeting lymphoma lesions with somatostatin receptor binding agents, mainly with In-111-pentetreotide. In the present work another somatostatin analog, Tc-99m depreotide, is investigated.
Methods: One-hundred and six patients, 47 with Hodgkin's (HL) and 59 with various types of non-Hodgkin's lymphoma (NHL), were imaged with both Tc-99m depreotide and Ga-67 citrate.
Objective: To investigate the effect of acquisition arc (180 degrees or 360 degrees ) and attenuation correction (AC), in artifact occurrence and image uniformity of myocardial perfusion SPECT studies in normal hearts.
Methods: Twenty male and 44 female patients with primary hyperparathyroidism and low probability of resting perfusion abnormalities were analysed. Tc-sestamibi myocardial perfusion studies were performed at rest with a hybrid SPECT/CT system.