Publications by authors named "Christos P Dimitroukas"

. To establish institutional diagnostic reference levels (IDRLs) based on clinical indications (CIs) for three- and four-phase computed tomography urography (CTU)..

View Article and Find Full Text PDF

The GORE EXCLUDER Conformable abdominal aortic aneurysm (AAA) Endoprosthesis (CEXC), is currently the newest stent-graft system for treating patients with AAA. CEXC is approved for patients with proximal aortic neck angles ≤90° with a ≥15 mm aortic neck length or proximal aortic neck angles ≤60° with ≥10 mm aortic neck length. The present study describes a clinical series of 5 males with AAA, one of whom had a ruptured infrarenal AAA and a 90° proximal aortic neck angle.

View Article and Find Full Text PDF

In this study, the effect of body-mass-index (BMI) on organ doses (ODs) during infrarenal endovascular-aneurysm-repair (EVAR) procedures was evaluated. Patient- and intra-operative data from fifty-nine EVAR procedures were inserted into VirtualDose-IR software to calculate ODs. For overweight, obesity class-I and obesity class-II, ODs were up to 147%, 412% and 775% higher than those for normal weight-patients, respectively.

View Article and Find Full Text PDF

Patients who undergo endovascular aortic aneurysm repair (EVAR) may require prolonged radiation exposure affected by several factors. The objectives of this study were to document fluoroscopy time (FT) during EVAR and identify possible factors that influence it. A retrospective analysis of a 180 patients' database with abdominal infrarenal aortic aneurysms submitted to EVAR during a 7-y period was performed.

View Article and Find Full Text PDF

Introduction: Our purpose was to review the scientific literature and collect information regarding clinical and technical parameters of different single- or multiphase CT protocols, their diagnostic performance and patient dose during parathyroid imaging.

Evidence Acquisition: PubMed and Scopus databases were searched for studies investigating the diagnostic performance of CT in detecting parathyroid lesions and the corresponding patients' dose. The following information was retrieved for each article: CT system, number, combination and time interval between phases, scanning length, sensitivity, specificity, accuracy, positive and negative predictive values, contrast enhancement in Hounsfield Units (HUs), technical and exposure parameters, and dose indices.

View Article and Find Full Text PDF

Objective: To estimate organs' absorbed dose from the two-phase CT of parathyroid glands, effective dose (ED) based on three different methods, and compare the dose values with those reported by other published protocols.

Methods: Volumetric-computed-tomography-dose-index (CTDI), dose-length-product (DLP), and the corresponding scan length during each phase of a parathyroid protocol were recorded, for seventy-six patients. One k-factor, and two different k-factors for the neck and chest area were used to estimate the ED from DLP.

View Article and Find Full Text PDF

This study evaluates the patient radiation dose from the two-phase protocols of two different computed tomography (CT) systems and compares this with that delivered by the other similar protocols previously published. Two hundred and fourteen patients with primary hyperparathyroidism were included in the study with a two-phase CT scan between 2008 and 2020 by using a Toshiba Aquilion Prime 80 and a GE Light Speed 16. The standard 'neck' or a modified 'parathyroid' protocol was used.

View Article and Find Full Text PDF

This study aims to evaluate patient radiation dose during fluoroscopically guided endovascular aneurysm repair (EVAR) procedures. Fluoroscopy time (FT) and kerma-area product (KAP) were recorded from 87 patients that underwent EVAR procedures with a mobile C-arm fluoroscopy system. Effective dose (ED) and organs' doses were calculated utilising appropriate conversion coefficients based on the recorded KAP values.

View Article and Find Full Text PDF

Background: Radiation exposure during endovascular repair (EVAR) of abdominal aortic aneurysms (AAAs) is a potential issue. Several studies have identified factors affecting radiation exposure, although they are limited. The aim of this study was to identify independent factors affecting radiation exposure in patients with AAA undergoing standard EVAR.

View Article and Find Full Text PDF

In this study, the radiation dose received by 364 low body mass index (BMI) adult patients undergoing chest, abdomen, lumbar spine, kidneys and urinary bladder (KUB) and pelvis X-ray examinations in an X-ray room with a digital radiography system was evaluated. The patients' kerma area product (KAP) values were recorded, and the entrance surface air kerma (ESAK) was calculated based on the X-ray tube output, exposure parameters and technical data. The 75th percentiles of the distribution of ESAK and KAP values were also estimated.

View Article and Find Full Text PDF