Convolutional neural networks (CNNs), initially developed for image processing applications, have recently received significant attention within the field of medical ultrasound imaging. In this study, passive cavitation imaging/mapping (PCI/PAM), which is used to map cavitation sources based on the correlation of signals across an array of receivers, is evaluated. Traditional reconstruction techniques in PCI, such as delay-and-sum, yield high spatial resolution at the cost of a substantial computational time.
View Article and Find Full Text PDFUltrasound stimulated microbubbles have been shown to be capable of breaking up blood clots through micro-scale interactions occurring near the clot surface. However, only a small fraction of bubbles circulating in the bloodstream will be in close proximity to such boundaries, where they must be to elicit therapeutic effects. Here, the accumulation and subsequent behavior of microbubbles displaced from an overlying flow channel to a boundary under radiation forces were examined.
View Article and Find Full Text PDFIt is established that radiation forces can be used to transport ultrasound contrast agents, particularly for molecular imaging applications. However, the ability to model and control this process in the context of therapeutic ultrasound is limited by a paucity of data on the translational dynamics of encapsulated microbubbles under the influence of longer pulses. In this work, the translation of individual microbubbles, isolated with optical tweezers, was experimentally investigated over a range of diameters (1.
View Article and Find Full Text PDFHigh intensity focused ultrasound (HIFU) can disintegrate blood clots through the generation and stimulation of bubble clouds within thrombi. This work examined the design of a device to image bubble clouds for monitoring cavitation-based HIFU treatments of deep vein thrombosis (DVT). Acoustic propagation simulations were carried out on multi-layered models of the human thigh using two patient data sets from the Visible Human Project.
View Article and Find Full Text PDFIt is well established that high intensity focused ultrasound can be used to disintegrate clots. This approach has the potential to rapidly and noninvasively resolve clot causing occlusions in cardiovascular diseases such as deep vein thrombosis (DVT). However, lack of an appropriate treatment monitoring tool is currently a limiting factor in its widespread adoption.
View Article and Find Full Text PDFSerial two-photon microscopy of blood clots with fluorescently tagged fibrin networks was conducted during microbubble-mediated sonothrombolysis to examine the microscale evolution of the resulting erosion front. The development of a complex zonal erosion pattern was observed, comprised of a cell depleted layer of fibrin network overlying intact clot which then underwent progressive recession. The fibrin zone architecture was dependent on exposure conditions with 0.
View Article and Find Full Text PDF