Purpose: This study aims to reduce the delivery time of CyberKnife m6 treatments by allowing for noncoplanar continuous arc delivery. To achieve this, a novel noncoplanar continuous arc delivery optimization algorithm was developed for the CyberKnife m6 treatment system (CyberArc-m6).
Methods And Materials: CyberArc-m6 uses a five-step overarching strategy, in which an initial set of beam geometries is determined, the robotic delivery path is calculated, direct aperture optimization is conducted, intermediate MLC configurations are extracted, and the final beam weights are computed for the continuous arc radiation source model.
Purpose/objectives: For lung stereotactic body radiation therapy (SBRT), real-time tumor tracking (RTT) allows for less radiation to normal lung compared to the internal target volume (ITV) method of respiratory motion management. To quantify the advantage of RTT, we examined the difference in radiation pneumonitis risk between these two techniques using a normal tissue complication probability (NTCP) model.
Materials/method: 20 lung SBRT treatment plans using RTT were replanned with the ITV method using respiratory motion information from a 4D-CT image acquired at the original simulation.
The goal of this study is to demonstrate the feasibility of a novel non-coplanar-arc optimization algorithm (CyberArc). This method aims to reduce the delivery time of conventional CyberKnife treatments by allowing for continuous beam delivery. CyberArc uses a 4 step optimization strategy, in which nodes, beams, and collimator sizes are determined, source trajectories are calculated, intermediate radiation models are generated, and final monitor units are calculated, for the continuous radiation source model.
View Article and Find Full Text PDFThe purpose of this study was to evaluate the performance of a commercially avail-able CyberKnife system with a multileaf collimator (CK-MLC) for stereotactic body radiotherapy (SBRT) and standard fractionated intensity-modulated radiotherapy (IMRT) applications. Ten prostate and ten intracranial cases were planned for the CK-MLC. Half of these cases were compared with clinically approved SBRT plans generated for the CyberKnife with circular collimators, and the other half were compared with clinically approved standard fractionated IMRT plans generated for conventional linacs.
View Article and Find Full Text PDFPurpose: A unique capability of the CyberKnife system is dynamic target tracking. However, not all patients are eligible for this approach. Rather, their tumors are tracked statically using the vertebral column for alignment.
View Article and Find Full Text PDFTechnol Cancer Res Treat
February 2015
Stereotactic body radiation therapy (SBRT) to central lung tumors is associated with normal -tissue toxicity. Highly conformal technologies may reduce the risk of complications. This study compares physical dose characteristics and anticipated risks of radiation pneumonitis (RP) among three SBRT modalities: robotic radiosurgery (RR), helical tomotherapy (HT) and volumetric modulated arc therapy (VMAT).
View Article and Find Full Text PDFThe quest for less costly and more compact high-energy particle accelerators makes research on alternative acceleration mechanisms an important enterprise. From the multitude of suggested concepts, the photonic accelerator design by B. M.
View Article and Find Full Text PDFOn-board cone-beam computed tomography (CBCT) has recently become available to provide volumetric information of a patient in the treatment position, and holds promises for improved target localization and irradiation dose verification. The design of currently available on-board CBCT, however, is far from optimal. Its quality is adversely influenced by many factors, such as scatter, beam hardening, and intra-scanning organ motion.