J Shoulder Elbow Surg
September 2022
Background: Glenoid bone loss is one of the main challenges in revision of failed shoulder arthroplasties. The concept of a hemi-reverse procedure is to implant a glenoid baseplate and glenosphere to protect the glenoid reconstruction to allow it to heal and to preserve the joint space for a potential second-stage humeral component implantation. The purpose of this study was to report the results of hemi-reverse procedures.
View Article and Find Full Text PDFBackground: Internal rotation (IR) with reverse total shoulder arthroplasty (rTSA) can be unpredictable. Identifying the factors associated with loss of or improved IR could aid preoperative patient counseling. This study quantifies the change in IR experienced by rTSA patients with nonfracture indications and identifies the patient, implant, and operative factors associated with IR loss or gain at 2-year minimum follow-up.
View Article and Find Full Text PDFPurpose: Clinical shoulder science lacks a benchmark against which the early clinical value of new glenoid components can be compared; such a benchmark may be derived from a multicenter study of patients receiving an established, internationally used design of glenoid component.
Methods: We obtained data from 11 centers on 1270 patients having total shoulder arthroplasty using an all-polyethylene component with a fluted central peg. We analyzed individual patient outcomes at 1 and 2 years after surgery.
Background: Several short-stemmed press-fit humeral components have been developed in recent years for anatomic total shoulder arthroplasty (TSA) as well as reverse shoulder arthroplasty (RSA). Varying radiographic outcomes have been reported, with some studies reporting concerning rates of aseptic loosening. This study analyzed the radiographic findings of a press-fit convertible short-stemmed humeral component in both TSA and RSA.
View Article and Find Full Text PDFBackground: Scapular stress fractures after reverse shoulder arthroplasty (RSA) are a potentially serious complication with modern lateralized and onlay implants. The aim of this study was to report the scapular spine stress fracture rate after RSA with an onlay, 145° humeral stem, analyzing potential fracture risk factors and clinical outcomes in a large cohort of patients.
Methods: A consecutive series of 485 RSAs were implanted with the Aequalis Ascend Flex stem.
Background: Radiographic lucency of the glenoid component remains a problem after cement fixation in primary total shoulder arthroplasty. Glenoid component design likely contributes to rates of glenoid lucency. The purpose of this study was to prospectively compare radiographic lucency between a finned, cementless central pegged glenoid component (CL component) and a conventional cemented pegged glenoid component (P component) on immediate postoperative and minimum 2-year follow-up radiographs.
View Article and Find Full Text PDFBackground: There is limited information assessing outcomes after total shoulder arthroplasty (TSA) with a press-fit short stem. The purpose of this study was to evaluate early clinical and radiographic outcomes and complications after TSA with an anatomic press-fit short stem.
Methods: We identified 118 TSAs completed with press-fit short stem and minimum 2-year follow-up; 85 of these patients had a grit-blasted (GB) short stem placed, whereas 33 patients had short stems with proximal porous coating (PPC).
Background: Glenoid component loosening remains a significant issue after anatomic shoulder arthroplasty. Pegged glenoid components have shown better lucency rates than keeled components in the short term; however, midterm to long-term results have not fully been determined. We previously reported early outcomes of the current randomized controlled group of patients, with higher glenoid lucency rates in those with a keeled glenoid.
View Article and Find Full Text PDF