Unlabelled: Diagnostic accuracy and therapeutic decision-making for IDH-mutant gliomas in tumor board reviews are based on MRI and multidisciplinary interactions.
Materials And Methods: This study explores the feasibility of deep learning-based reconstruction (DLR) in MRI for IDH-mutant gliomas. The research utilizes a multidisciplinary approach, engaging neuroradiologists, neurosurgeons, neuro-oncologists, and radiotherapists to evaluate qualitative aspects of DLR and conventional reconstructed (CR) sequences.
Background: Photon-counting (PC) CT has the potential to improve diagnostic confidence and image quality of CT angiography (CTA) in patients with peripheral artery disease (PAD).
Purpose: To retrospectively evaluate the diagnostic performance of Photon-counting CT angiography for the assessment of stenotic disease in patients with PAD compared to digital subtraction angiography (DSA) as gold standard.
Materials And Methods: All patients undergoing PC CTA followed by DSA between November 2021 and November 2023 were included in this institutional review board approved HIPAA compliant retrospective analysis.
Background: Time-resolved angiography with interleaved stochastic trajectories (TWIST) magnetic resonance angiography (MRA) may obscure smaller vessels and is highly susceptibility to motion artifacts, potentially reducing endoleak detection accuracy after endovascular aortic repair (EVAR). The novel golden-angle radial sparse parallel (GRASP) sequence enhances spatial and temporal resolution with continuous, motion-robust datasets, showing promise for accurate endoleak detection post-EVAR. This study aimed to compare the diagnostic effectiveness of contrast-enhanced compressed-sensing radial GRASP-volume interpolated breath-hold examination (VIBE) sequence with standard contrast-enhanced dynamic TWIST-VIBE sequence in patients with inconclusive computed tomography angiography (CTA) findings regarding endoleak after EVAR.
View Article and Find Full Text PDFBackground CT-derived fractional flow reserve (CT-FFR) and dynamic CT myocardial perfusion imaging enhance the specificity of coronary CT angiography (CCTA) for ruling out coronary artery disease (CAD). However, evidence on comparative diagnostic value remains scarce. Purpose To compare the diagnostic accuracy of CCTA plus CT-FFR, CCTA plus CT perfusion, and sequential CCTA plus CT-FFR and CT perfusion for detecting hemodynamically relevant CAD with that of invasive angiography.
View Article and Find Full Text PDF: To assess free-breathing, dynamic radial magnetic resonance angiography (MRA) for detecting endoleaks post-endovascular aortic repair (EVAR) in cases with inconclusive computed tomography angiography (CTA). : This prospective single-center study included 17 participants (mean age, 70 ± 9 years; 13 males) who underwent dynamic radial MRI (Golden-angle RAdial Sparse Parallel-Volumetric Interpolated BrEath-hold, GRASP-VIBE) after inconclusive multiphasic CT for the presence of endoleaks during the follow-up of EVAR-treated abdominal aortic aneurysms. CT and MRI datasets were independently assessed by two radiologists for image quality, diagnostic confidence, and the presence/type of endoleak.
View Article and Find Full Text PDFTo evaluate radiation exposure in standard interventional radiology procedures using a twin robotic X-ray system compared to a state-of-the-art conventional angiography system. Standard interventional radiology procedures (port implantation, SIRT, and pelvic angiography) were simulated using an anthropomorphic Alderson RANDO phantom (Alderson Research Laboratories Inc. Stamford, CT, USA) on an above-the-table twin robotic X-ray scanner (Multitom Rax, Siemens Healthineers, Forchheim, Germany) and a conventional below-the-table angiography system (Artis Zeego, Siemens Healthineers, Forchheim, Germany).
View Article and Find Full Text PDFBackground: The Viabahn stent graft has emerged as an integral tool for managing vascular diseases, but there is limited long-term data on its performance in emergency endovascular treatment. This study aimed to assess safety, technical success, and long-term efficacy of the Viabahn stent graft in emergency treatment of arterial injury.
Methods: We conducted a retrospective single tertiary centre analysis of patients who underwent Viabahn emergency arterial injury treatment between 2015 and 2020.
This study investigated the efficacy of single-phase dual-energy CT (DECT) in differentiating pulmonary hamartomas from malignant lung lesions using virtual non-contrast (VNC), iodine, and fat quantification. Forty-six patients with 47 pulmonary lesions (mean age: 65.2 ± 12.
View Article and Find Full Text PDFPurpose: To provide an overview of endovascular treatment of renal artery stenosis (RAS) using the data of the Deutsche Gesellschaft für interventionelle Radiologie (DeGIR) quality management system.
Materials And Methods: A retrospective analysis was performed. Pre-, peri- and postprocedural data, technical success rates, complication rates, and clinical success rates at dismissal were examined.
Objectives: In interventional bronchial artery embolization (BAE), periprocedural cone beam CT (CBCT) improves guiding and localization. However, a trade-off exists between 6-second runs (high radiation dose and motion artifacts, but low noise) and 3-second runs (vice versa). This study aimed to determine the efficacy of an advanced deep learning denoising (DLD) technique in mitigating the trade-offs related to radiation dose and image quality during interventional BAE CBCT.
View Article and Find Full Text PDFEven with liver-targeted therapies, uveal melanoma with hepatic metastasis remains a challenge. The aim of this study was to compare the outcome of patients treated with either SIRT or CS-PHP. We included 62 patients with hepatic metastasized uveal melanoma (n = 34 with SIRT, receiving 41 cycles; n = 28 with CS-PHP, receiving 56 cycles) that received their treatments between 12/2013 and 02/2020 at a single center.
View Article and Find Full Text PDFPurpose: To evaluate the safety and efficacy of percutaneous interventional treatment of portal vein stenosis in children.
Material And Methods: A retrospective analysis of all interventional treatments for portal vein stenosis in pediatric patients at a single institution from 2010 to 2021 was conducted. Platelet count, spleen size and portal vein flow velocity were assessed during the follow-up period.
Background And Objective: Vascular calcification (VC) and resulting vascular disease is one of the major causes of cardiovascular morbidity and mortality in patients with chronic kidney disease (CKD). CKD itself is increasingly recognized as a risk factor for cardiac and peripheral arterial disease (PAD). This paper examines the atherosclerotic plaque composition and specific endovascular considerations in the end stage renal disease (ESRD) patients.
View Article and Find Full Text PDFTo evaluate Quiescent Interval Slice Selective (QISS) balanced steady-state free precession (bSSFP) and QISS fast low-angle shot (FLASH) sequences for non-contrast Magnetic Resonance Angiography (MRA) of iliac arteries regarding image quality and diagnostic confidence in order to establish these sequences in daily clinical practice. A prospective study of healthy subjects (n = 10) was performed. All subjects underwent the QISS MRI protocol with bSSFP und FLASH sequences.
View Article and Find Full Text PDFBackground: Acute mesenteric ischemia (AMI) is a life-threatening condition resulting from occlusion of the mesenteric arterial vessels. AMI requires immediate treatment with revascularization of the occluded vessels. Purpose: to evaluate the technical success, clinical outcomes and survival of patients receiving endovascular treatment for AMI followed by surgery.
View Article and Find Full Text PDFObjectives: The aim of this study was to assess the endograft position and aortic geometry changes after thoracic endovascular aortic repair (TEVAR) and frozen elephant trunk (FET) in distal stent-induced new entry (dSINE) patients.
Methods: In this retrospective cohort study, the baseline demographic and the follow-up data were extracted from the hospital records, and computed tomography scans of dSINE patients after TEVAR or FET between 2011 and 2021 were analysed regarding endograft oversizing, length and migration, taper ratio, aortic diameter at the endograft end, aortic elongation (thoracic inner and outer curvature), wedge apposition angle and tortuosity angle in the distal landing zone.
Results: dSINE was found in 22/213 (10%) of TEVAR and 10/31 (32%) of FET patients.
The purpose of this study was to evaluate the potential of dual-energy CT (DECT) with virtual unenhanced imaging (VNC) and iodine maps (IM) to differentiate between intraperitoneal hematomas (IH) and bowel structures (BS) compared to linearly blended DECT (DE-LB) images (equivalent to single-energy CT). This retrospective study included the DECT of 30 patients (mean age: 64.5 ± 15.
View Article and Find Full Text PDFPurpose: To evaluate the safety and efficacy of rotational thrombectomy (RT) in a large single-center real-world cohort for total vascular occlusions of the lower extremity.
Materials And Methods: The clinical records and images of all patients between 2010 and 2020 treated via RT (Rotarex, BD) were assessed. Patient demographics, clinical data, procedural characteristics, and outcome parameters were documented.
PURPOSE The purpose of this study is to systematically evaluate the effect of tube voltage, current kernels, and monoenergetic post-processing on stent visualization. METHODS A 6 mm chrome-cobalt peripheral stent was placed in a dedicated phantom and scanned with the available tube voltage settings of a third-generation dual-source scanner in single-energy (SE) and dual-energy (DE) mode. Images were reconstructed using the latest convolution kernels and monoenergetic reconstructions (40-190 keV) for DE.
View Article and Find Full Text PDFThe aim was to evaluate the accuracy of a prototypical artificial intelligence-based algorithm for automated segmentation and diameter measurement of the thoracic aorta (TA) using CT. One hundred twenty-two patients who underwent dual-source CT were retrospectively included. Ninety-three of these patients had been administered intravenous iodinated contrast.
View Article and Find Full Text PDFPURPOSE Differentiation of incidental adrenal lesions remains a challenge in diagnostic imaging, especially on single-phase portal venous computed tomography (CT) in the oncological setting. The aim of the study was to explore the ability of dual-energy CT (DECT)-based iodine quantification and virtual non-contrast (VNC) imaging and advanced radiomic analysis of DECT for differentiation of adrenal adenomas from metastases. METHODS A total of 46 patients with 49 adrenal lesions underwent clinically indicated staging DECT and magnetic resonance imaging.
View Article and Find Full Text PDF(1) To investigate whether interventional cone-beam computed tomography (cbCT) could benefit from AI denoising, particularly with respect to patient body mass index (BMI); (2) From 1 January 2016 to 1 January 2022, 100 patients with liver-directed interventions and peri-procedural cbCT were included. The unenhanced mask run and the contrast-enhanced fill run of the cbCT were reconstructed using weighted filtered back projection. Additionally, each dataset was post-processed using a novel denoising software solution.
View Article and Find Full Text PDF