Publications by authors named "Christina Brinkmann"

Background: Severe pure aortic regurgitation (AR) carries a high mortality and morbidity risk, and it is often undertreated because of the inherent surgical risk. Transcatheter heart valves (THVs) have been used off-label in this setting with overall suboptimal results. The dedicated "purpose-built" Jena Valve Trilogy (JVT, JenaValve Technology) showed an encouraging performance, although it has never been compared to other THVs.

View Article and Find Full Text PDF
Article Synopsis
  • Transcatheter aortic valve replacement (TAVR) for severe native aortic valve regurgitation has shown suboptimal outcomes, particularly with older valve technologies; this study evaluates newer devices.
  • The PANTHEON study analyzed 201 patients who received TAVR with both self-expanding and balloon-expandable valves, focusing on success rates and health outcomes after one year.
  • Results revealed that while technical success was high, issues like transcatheter valve embolization occurred in a significant number of cases, indicating that TAVR still poses challenges despite advancements in valve technology.
View Article and Find Full Text PDF

Objectives: The authors sought to evaluate the incidence, predictors, and outcomes of new permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) with contemporary self-expanding valves (SEV).

Background: Need for PPI is frequent post-TAVR, but conflicting data exist on new-generation SEV and on the prognostic impact of PPI.

Methods: This study included 3,211 patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries (January 2012 to December 2021) who underwent transfemoral TAVR with SEV.

View Article and Find Full Text PDF

Background: The ACURATE neo2 (NEO2) and Evolut PRO/PRO+ (PRO) bioprostheses are new-generation self-expanding valves developed for transcatheter aortic valve replacement (TAVR).

Aims: We sought to compare the performance of the ACURATE neo2 and Evolut PRO/PRO+ devices.

Methods: The NEOPRO-2 registry retrospectively included patients who underwent TAVR for severe aortic stenosis with either the NEO2 or PRO devices between August 2017 and December 2021 at 20 centres.

View Article and Find Full Text PDF
Article Synopsis
  • Severe prosthesis-patient mismatch (PPM) is linked to negative outcomes after transcatheter aortic valve replacement (TAVR), and this study investigates its effects in patients undergoing a second TAVR (TAV-in-TAVR).
  • The study analyzed data from 155 patients across 28 centers, finding that 6.5% experienced severe PPM and 14.2% moderate PPM, with higher rates in specific TAVR types.
  • Results showed that severe PPM correlated with increased one-year all-cause mortality and worsened symptoms, although many patients saw improvement after receiving a new valve to treat the mismatch.
View Article and Find Full Text PDF

Objectives: This study evaluated the incidence, management, and outcome of patients who experienced MitraClip (Abbott Vascular) failure secondary to loss of leaflet insertion (LLI), single leaflet detachment (SLD), or embolization.

Background: Transcatheter edge-to-edge repair with MitraClip is an established therapy for the treatment of mitral regurgitation (MR), but no data exist regarding the prevalence and outcome according to the mode of clip failure.

Methods: Between January 2009 and December 2020, we retrospectively screened 4,294 procedures of MitraClip performed in 19 centers.

View Article and Find Full Text PDF

Background: Late Stanford type A aortic dissections (TAADs) are a very rare complication after transcatheter aortic valve implantation (TAVI). Surgery is the treatment of choice, but perioperative mortality (25%) and neurological complications (18%) remain high.

Case Summary: An 85-year-old male patient presented with acute chest pain 5 months after a transfemoral Evolut R 34 mm transcatheter heart valve (THV) implantation.

View Article and Find Full Text PDF

Background: Bioprosthetic valve fracture (BVF) is a technique to reduce gradients in valve-in-valve transcatheter aortic valve implantation (VIV-TAVI) procedures. The outcome of VIV-TAVI with BVF has not been compared with VIV-TAVI without BVF.

Aims: The aim of this study was to evaluate the outcome of VIV-TAVI with BVF compared to VIV-TAVI without BVF.

View Article and Find Full Text PDF

Objectives: To evaluate outcome and its predictors of bioprosthetic valve fracture (BVF) in patients undergoing valve-in-valve transcatheter aortic valve replacement (VIV-TAVR).

Background: BVF is feasible and reduces transvalvular gradients in VIV-TAVR-procedures, but follow-up-data and information on factors influencing the outcome are missing.

Methods: The 81 cases of BVF-VIV-TAVR were collected from 14 international centers.

View Article and Find Full Text PDF

Background: Permanent pacemaker implantation (PPI) remains one of the main drawbacks of transcatheter aortic valve replacement (TAVR), but scarce data exist on PPI after valve-in-valve (ViV) TAVR, particularly with the use of newer-generation transcatheter heart valves (THVs).

Objectives: The goal of this study was to determine the incidence, factors associated with, and clinical impact of PPI in a large series of ViV-TAVR procedures.

Methods: Data were obtained from the multicenter VIVID Registry and included the main baseline and procedural characteristics, in-hospital and late (median follow-up: 13 months [interquartile range: 3 to 41 months]) outcomes analyzed according to the need of periprocedural PPI.

View Article and Find Full Text PDF

Objective: To evaluate the risk for brain lesions in valve in valve (VIV)-transcatheter aortic valve replacement (TAVR) compared to native valve procedures (NV-TAVR).

Background: TAVR is associated with the risk of stroke and a high incidence of brain lesions in diffusion-weighted magnetic resonance imaging (DW-MRI). The risk in VIV procedures is unknown.

View Article and Find Full Text PDF

Aims: The aim of this study was to determine the feasibility of rotational atherectomy (RA) in chronic total occlusion (CTO) PCI and compare the success and complication rates of RA in CTO lesions versus non-occluded lesions. Data on RA in CTO are rare and it is unknown how procedural success and risk of RA in CTO lesions compare to RA in non-CTO lesions.

Methods And Results: RA was performed in 392 out of 17,919 PCI procedures (2.

View Article and Find Full Text PDF