Publications by authors named "Christin Arnold"

Objectives: The study compares three minimally invasive approaches for the retention of implant supported mandibular complete dentures, particularly focusing on patient satisfaction.

Background: The McGill Consensus Statement recommends restoration of the edentulous mandible with an overdenture retained on two implants. Alternatively, less invasive treatment concepts with shorter treatment times have been developed for critical cases.

View Article and Find Full Text PDF

: Despite the increasing use of chromatic intraoral scanners, color determination is often performed visually, offering poor reliability and validity. In this study, we aimed to compare the reliability and validity of the tooth shade determination tool of an intraoral scanner (Trios3 Color) with that of two dental spectrophotometers (VITA Easyshade Advance 4.0 and SpectroShade Micro) and with visual determination using the VITA 3D-Master shade guide.

View Article and Find Full Text PDF

Background: The risk of persistent postoperative opioid use (PPOU) and its association with the type of surgery are still unclear in Germany.

Methods: We conducted a nationwide retrospective cohort study on the basis of claims data from BARMER, a statutory health insurance carrier in Germany. Opioid-naive adults who did not have cancer and who underwent inpatient surgery in 2018 were included in the study.

View Article and Find Full Text PDF

Even in digital workflows, models are required for fitting during the fabrication of dental prostheses. This study examined the influence of different parameters on the dimensional accuracy of three-dimensionally printed models. A stereolithographic data record was generated from a master model (SOLL).

View Article and Find Full Text PDF

Cesarean section (CS) is the most widely performed and one of the most painful surgeries. This study investigated postoperative pain after CS using patient-related outcomes (PROs) to identify risk factors for severe pain. The secondary outcome was to evaluate the influence of surgery indication (primary CS (PCS) vs.

View Article and Find Full Text PDF
Article Synopsis
  • * A study evaluated data from over 330,000 patients to determine the prevalence of significant incisional pain post-surgery, finding an overall rate of 22.5%, with variations based on the type of surgery.
  • * Key factors linked to higher pain levels included younger age, early postoperative pain, insufficient pain relief, and surgical infections, impacting patient satisfaction and work recovery.
View Article and Find Full Text PDF

The microbial metagenome in cystic fibrosis (CF) airways was investigated by whole-genome shotgun sequencing of total DNA isolated from nasal lavage samples, oropharyngeal swabs, and induced sputum samples collected from 65 individuals with CF aged 7 to 50 years. Each patient harbored a personalized microbial metagenome unique in microbial load and composition, the exception being monocultures of the most common CF pathogens Staphylococcus aureus and Pseudomonas aeruginosa from patients with advanced lung disease. The sampling of the upper airways by nasal lavage uncovered the fungus Malassezia restricta and the bacterium Staphylococcus epidermidis as prominent species.

View Article and Find Full Text PDF

Purpose: The aim of the present study was to examine the retention force of monolithic zirconia copings cemented with various temporary cements on implant abutments in vitro.

Methods: Sixty exercise implants with pre-screwed implant abutments were embedded in resin. Subsequently, 60 CAD/CAM manufactured zirconia copings were divided into three main groups [Harvard Implant Semi-permanent (HAV), implantlink semi Forte (IMP), Temp Bond NE (TBNE)].

View Article and Find Full Text PDF

In cystic fibrosis (CF) therapy, the recent approval of CF-transmembrane conductance regulator (CFTR) channel modulators is considered to be the major breakthrough. However, the current first-line approach based mainly on pulmonary function to measure effects of the novel therapy, tested by forced expiratory volumes in one second (FEV), provides restricted sensitivity to detect early structural damages. Accordingly, there is a need for new sensitive surrogate parameters.

View Article and Find Full Text PDF

Acute postoperative pain is frequently evaluated by pain intensity scores. However, interpretation of the results is difficult and thresholds requiring treatment are not well defined. Additional patient-reported outcome measures (PROMs) might be helpful to better understand individual pain experience and quality of pain management after surgery.

View Article and Find Full Text PDF

Objective: The aim of this interlaboratory round robin test was to prove the robustness of the DIN EN ISO 6872:2019 and to identify the influence of processing and testing variations.

Methods: Each of the 12 laboratories participated (A-L) received 60 (n = 720) assigned zirconia specimens. All participants seperated the specimens from the blanks, sintered them, polished half of all specimens and performed the biaxial flexural test (DIN EN ISO 6872:2019).

View Article and Find Full Text PDF

Removable implant-anchored dentures have become an established treatment concept especially for older, multimorbid patients. This study investigates the retention force (RF) of two different attachment systems. A total of 96 specimens (n = 8 for each condition) were fabricated and RF was measured under different conditions: fatigue (10,000 cycles dislodging), thermal undulation (5/55 °C, 5000 cycles) and implant-angulation (0°, 5°, 10°, 15°, 20°).

View Article and Find Full Text PDF

Two-piece abutments consisting of customized zirconia abutment copings and prefabricated titanium bases are popular due to their biological and esthetic advantages. Glass-ceramic solder (GS) is an alternative biocompatible connective agent. This in vitro study evaluated the retentive force of GS in comparison to classical resin composite cements (RC) after artificial aging and autoclaving.

View Article and Find Full Text PDF

The aim of this study was to compare the retention forces after artificial aging of telescopic crowns fabricated either by a conventional lost-wax technique or by computer-aided design/computer-aided manufacturing (CAD-CAM) technology. Two types of telescopic crowns (0°) were fabricated conventionally using high-noble (group A) and non-precious metal (group B). CAD-CAM fabricated telescopic crowns (0°) were made of non-precious metal (group C).

View Article and Find Full Text PDF

Background: An ongoing debate in dental education is whether implant dentistry, as a multidisciplinary domain, should be integrated into the undergraduate curriculum. The aim of the present study was to evaluate the perspectives of novices, clinical educators, and experienced dentists with regard to the importance of theoretical and practical implant dentistry teaching content in undergraduate dental education. The specific objective was to determine whether a consensus could be found concerning aspects of theoretical knowledge, implant position planning, implantation, prosthetic treatment procedures, postoperative care, and prerequisite experiences that should be provided in undergraduate dental education.

View Article and Find Full Text PDF

Objectives: Several in vitro studies have investigated the retention of double crowns with friction pins (DCP); however, clinical data on their long-term success have not been reported. We sought to evaluate the 5-year survival rate of DCPs in patients with severely reduced dentition (SRD) and not severely reduced dentition (NSRD).

Materials And Methods: A total of 158 patients were treated with 182 dentures on 520 abutment teeth between 2006 and 2016.

View Article and Find Full Text PDF

Objectives: This study aimed to evaluate the effects of endodontic treatment on the complication rate in abutment teeth following double crown treatment.

Materials And Methods: Data of 233 patients supplied with 278 prostheses on 773 teeth were retrospectively analyzed. The 60-month cumulative complication rate for vital, root filled, and post and core reconstructed abutment teeth is calculated using the Kaplan-Meier method.

View Article and Find Full Text PDF

Although 3D-printing is common in dentistry, the technique does not produce the required quality for all target applications. Resin type, printing resolution, positioning, alignment, target structure, and the type and number of support structures may influence the surface roughness of printed objects, and this study investigates the effects of these variables. A stereolithographic data record was generated from a master model.

View Article and Find Full Text PDF

Objective: Infection control protocols in dentistry dictate that orthodontic acrylics have to be disinfected. No specific products for orthodontic acrylics are available. The objective of this study was to investigate the influence of chemical disinfectants on mechanical properties of orthodontic acrylics.

View Article and Find Full Text PDF

Background And Objective: For people with cystic fibrosis, validated patient-reported outcome measures for the assessment of the complex abdominal involvement are lacking. The objective of this study was to examine whether the CFAbd-Score, a novel questionnaire consisting of 28 items, meets the essential requirements (validity and reliability) for a patient-reported outcome measure according to US Food and Drug Administration recommendations.

Methods: Content validity was assessed by recording the frequencies and severity of symptoms that occurred during the prior 2 weeks in patients with cystic fibrosis (n = 116; aged ≥ 6 years).

View Article and Find Full Text PDF

Objectives: Previously, we found linkages of inflammatory mediator levels in CF upper airways (UAW) sampled by nasal lavage (NL) to disease severity and to chronic pathogen colonization such as Pseudomonas aeruginosa (PsA). Here, we assess UAW cytokine dynamics in CF patients with a new PsA colonization.

Methods: We measured cytokines in 149 longitudinally obtained NL samples from 34 CF patients.

View Article and Find Full Text PDF

Abdominal symptoms are a hallmark of Cystic fibrosis (CF). Yet, their association with morphological abnormalities of different abdominal organs is still poorly understood. Aim was therefore to relate these symptoms, assessed with a questionnaire, to findings in abdominal ultrasound (US).

View Article and Find Full Text PDF

Objectives: The aim of the study was to compare the retentive behaviors of double crowns with different designs and material compositions before and after artificial aging.

Materials And Methods: Six pairs of double crowns were fabricated: telescopic crowns 0° made of high-noble metal (group A) or non-precious metal (group B), telescopic zirconia copings with secondary crowns made of electroplated gold 2° (group C), crowns with friction pins 2° made of non-precious metal (group D) or zirconia (group E), and conical crowns 6° made of high-noble metal (group F). Retention forces were assessed before and after artificial aging, and after axial and non-axial loading.

View Article and Find Full Text PDF

Statement Of Problem: The conventional fabrication of removable partial dentures (RPDs) is a complex, error-prone, time-consuming, and expensive process. The use of computer-aided design and computer-aided manufacturing (CAD-CAM) techniques, especially rapid prototyping, promises a more effective method for fabricating RPD frameworks.

Purpose: The purpose of this in vitro study was to evaluate the fit of RPD clasps fabricated by means of 4 different CAD-CAM-systems and to compare those fittings with that of the conventional lost-wax casting technique (LWT).

View Article and Find Full Text PDF