Phys Imaging Radiat Oncol
July 2022
Background And Purpose: Magnetic resonance (MR)-linac delivery is expected to improve organ at risk (OAR) sparing. In this study, OAR doses were compared for online adaptive MR-linac treatments and conventional cone beam computed tomography (CBCT)-linac radiotherapy, taking into account differences in clinical workflows, especially longer session times for MR-linac delivery.
Materials And Methods: For 25 patients with pelvic/abdominal lymph node oligometastases, OAR doses were calculated for clinical pre-treatment and daily optimized 1.