Publications by authors named "Chris Cagnon"

Purpose: The purpose of this work was to estimate and compare breast and lung doses of chest CT scans using organ-based tube current modulation (OBTCM) to those from conventional, attenuation-based automatic tube current modulation (ATCM) across a range of patient sizes.

Methods: Thirty-four patients (17 females, 17 males) who underwent clinically indicated CT chest/abdomen/pelvis (CAP) examinations employing OBTCM were collected from two multi-detector row CT scanners. Patient size metric was assessed as water equivalent diameter (D ) taken at the center of the scan volume.

View Article and Find Full Text PDF

Purpose: Task Group Report 195 of the American Association of Physicists in Medicine contains reference datasets for the direct comparison of results among different Monte Carlo (MC) simulation tools for various aspects of imaging research that employs ionizing radiation. While useful for comparing and validating MC codes, that effort did not provide the information needed to compare absolute dose estimates from CT exams. Therefore, the purpose of this work is to extend those efforts by providing a reference dataset for benchmarking fetal dose derived from MC simulations of clinical CT exams.

View Article and Find Full Text PDF

Purpose: The purpose of this work was to estimate scanner-independent CTDI -to-fetal-dose coefficients for tube current-modulated (TCM) and fixed tube current (FTC) computed tomography (CT) examinations of pregnant patients of various gestational ages undergoing abdominal/pelvic CT examinations.

Methods: For 24 pregnant patients of gestational age from <5 to 36 weeks who underwent clinically indicated CT examinations, voxelized models of maternal and fetal (or embryo) anatomy were created from abdominal/pelvic image data. Absolute fetal dose (D ) was estimated using Monte Carlo (MC) simulations of helical scans covering the abdomen and pelvis for TCM and FTC scans.

View Article and Find Full Text PDF
Article Synopsis
  • The objective of the study was to develop size-specific dose estimates (SSDE) conversion factors for helical head CT examinations tailored for patients of varying sizes, addressing a limitation of existing factors primarily focused on body CT.
  • Researchers utilized Monte Carlo simulations on various voxelized models to accurately estimate radiation doses from CT scans across different patient age and size demographics.
  • The results indicated that the normalized mean doses to the brain showed an exponential relationship with the water equivalent diameter, suggesting that patient size significantly impacts radiation exposure during head CT scans.
View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to estimate the radiation doses to the lungs and breasts during tube current modulated (TCM) lung cancer screening scans, considering different patient sizes.
  • Monte Carlo methods were employed to perform detailed dose calculations using voxelized phantom and patient models, identifying various radiosensitive organs involved in the scans.
  • Results highlighted how different patient sizes, represented by a water equivalent diameter, influenced the radiation output metrics and organ-specific doses during low-dose lung cancer screening protocols.
View Article and Find Full Text PDF

Purpose: Currently, available Computed Tomography dose metrics are mostly based on fixed tube current Monte Carlo (MC) simulations and/or physical measurements such as the size specific dose estimate (SSDE). In addition to not being able to account for Tube Current Modulation (TCM), these dose metrics do not represent actual patient dose. The purpose of this study was to generate and evaluate a dose estimation model based on the Generalized Linear Model (GLM), which extends the ability to estimate organ dose from tube current modulated examinations by incorporating regional descriptors of patient size, scanner output, and other scan-specific variables as needed.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to assess the accuracy of a Monte Carlo simulation-based method for estimating radiation dose from multidetector computed tomography (MDCT) by comparing simulated doses in ten patients to in-vivo dose measurements.

Methods: MD Anderson Cancer Center Institutional Review Board approved the acquisition of in-vivo rectal dose measurements in a pilot study of ten patients undergoing virtual colonoscopy. The dose measurements were obtained by affixing TLD capsules to the inner lumen of rectal catheters.

View Article and Find Full Text PDF

Purpose: Task Group 204 introduced effective diameter (ED) as the patient size metric used to correlate size-specific-dose-estimates. However, this size metric fails to account for patient attenuation properties and has been suggested to be replaced by an attenuation-based size metric, water equivalent diameter (DW). The purpose of this study is to investigate different size metrics, effective diameter, and water equivalent diameter, in combination with regional descriptions of scanner output to establish the most appropriate size metric to be used as a predictor for organ dose in tube current modulated CT exams.

View Article and Find Full Text PDF

Purpose: AAPM Task Group 204 introduced size-specific dose estimates for pediatric and adult patients undergoing body CT examinations. This investigation extends that work to head CT exams by using Monte Carlo simulations to develop size-specific, scanner-independent CTDIvol-to-organ-dose conversion coefficients.

Methods: Using eight patient models from the GSF family of voxelized phantoms, dose to the brain and lens of the eye was estimated using Monte Carlo simulations of contiguous axial and helical scans for 64-slice multidetector CT scanners from four major manufacturers.

View Article and Find Full Text PDF
Article Synopsis
  • Monte Carlo (MC) simulation methods are popularly used in patient dose estimation during computed tomography (CT) scans, but they often lack thorough validation with diverse phantoms, especially as scanning techniques become more complex and use tube current modulation (TCM).
  • This study aims to validate an MC model designed for CT dose quantification by comparing it with actual measurements taken under various conditions, including fixed tube current (FTC) and TCM across multiple phantom types.
  • The validation process involved using both simple geometric phantoms and more complex, heterogeneous phantoms to assess the model's accuracy in simulating dose variations based on different modulation techniques during CT scans.
View Article and Find Full Text PDF

Purpose: CT neuroperfusion examinations are capable of delivering high radiation dose to the skin or lens of the eyes of a patient and can possibly cause deterministic radiation injury. The purpose of this study is to: (a) estimate peak skin dose and eye lens dose from CT neuroperfusion examinations based on several voxelized adult patient models of different head size and (b) investigate how well those doses can be approximated by some commonly used CT dose metrics or tools, such as CTDIvol, American Association of Physicists in Medicine (AAPM) Report No. 111 style peak dose measurements, and the ImPACT organ dose calculator spreadsheet.

View Article and Find Full Text PDF
Article Synopsis
  • The study expands the size-specific dose estimate (SSDE) concept to include tube current modulation (TCM) for CT scans, addressing a gap in previous research that only focused on fixed tube currents.
  • Thirty-nine adult abdomen/pelvis and 32 chest CT scans were analyzed, using patient anatomy to enhance the accuracy of dose estimates through Monte Carlo simulations.
  • The research calculated regional and organ-specific CTDI(vol) values to optimize dose normalization methods and improve overall patient safety in radiographic imaging.
View Article and Find Full Text PDF

Purpose: Most methods to estimate patient dose from computed tomography (CT) exams have been developed based on fixed tube current scans. However, in current clinical practice, many CT exams are performed using tube current modulation (TCM). Detailed information about the TCM function is difficult to obtain and therefore not easily integrated into patient dose estimate methods.

View Article and Find Full Text PDF

Objective: The purpose of our study was to accurately estimate the radiation dose to skin and the eye lens from clinical CT brain perfusion studies, investigate how well scanner output (expressed as volume CT dose index [CTDI(vol)]) matches these estimated doses, and investigate the efficacy of eye lens dose reduction techniques.

Materials And Methods: Peak skin dose and eye lens dose were estimated using Monte Carlo simulation methods on a voxelized patient model and 64-MDCT scanners from four major manufacturers. A range of clinical protocols was evaluated.

View Article and Find Full Text PDF

Purpose: A recent work has demonstrated the feasibility of estimating the dose to individual organs from multidetector CT exams using patient-specific, scanner-independent CTDIvol-to-organ-dose conversion coefficients. However, the previous study only investigated organ dose to a single patient model from a full-body helical CT scan. The purpose of this work was to extend the validity of this dose estimation technique to patients of any size undergoing a common clinical exam.

View Article and Find Full Text PDF

Purpose: Monte Carlo radiation transport techniques have made it possible to accurately estimate the radiation dose to radiosensitive organs in patient models from scans performed with modern multidetector row computed tomography (MDCT) scanners. However, there is considerable variation in organ doses across scanners, even when similar acquisition conditions are used. The purpose of this study was to investigate the feasibility of a technique to estimate organ doses that would be scanner independent.

View Article and Find Full Text PDF

Purpose: Previous work has demonstrated that there are significant dose variations with a sinusoidal pattern on the peripheral of a CTDI 32 cm phantom or on the surface of an anthropomorphic phantom when helical CT scanning is performed, resulting in the creation of "hot" spots or "cold" spots. The purpose of this work was to perform preliminary investigations into the feasibility of exploiting these variations to reduce dose to selected radiosensitive organs solely by varying the tube start angle in CT scans.

Methods: Radiation dose to several radiosensitive organs (including breasts, thyroid, uterus, gonads, and eye lenses) resulting from MDCT scans were estimated using Monte Carlo simulation methods on voxelized patient models, including GSF's Baby, Child, and Irene.

View Article and Find Full Text PDF

The purpose of this study was to present a method for generating x-ray source models for performing Monte Carlo (MC) radiation dosimetry simulations of multidetector row CT (MDCT) scanners. These so-called "equivalent" source models consist of an energy spectrum and filtration description that are generated based wholly on the measured values and can be used in place of proprietary manufacturer's data for scanner-specific MDCT MC simulations. Required measurements include the half value layers (HVL1 and HVL2) and the bowtie profile (exposure values across the fan beam) for the MDCT scanner of interest.

View Article and Find Full Text PDF

The larger coverage afforded by wider z-axis beams in multidetector CT (MDCT) creates larger cone angles and greater beam divergence, which results in substantial surface dose variation for helical and contiguous axial scans. This study evaluates the variation of absorbed radiation dose in both cylindrical and anthropomorphic phantoms when performing helical or contiguous axial scans. The approach used here was to perform Monte Carlo simulations of a 64 slice MDCT.

View Article and Find Full Text PDF