After a fracture, patients have reduced willingness to bend and extend their elbow joint due to pain, resulting in muscle atrophy, contracture, and stiffness around the elbow. Moreover, this may lead to progressive atrophy of the muscles around the elbow, resulting in permanent functional loss. Currently, a goniometer is used to measure the range of motion, ROM, to evaluate the recovery of the affected limb.
View Article and Find Full Text PDFIn this study, we developed a range of motion sensing system (ROMSS) to simulate the function of the elbow joint, with errors less than 0.76 degrees and 0.87 degrees in static and dynamic verification by the swinging and angle recognition modules, respectively.
View Article and Find Full Text PDFIn the real condition, the small sensor found it difficult to detect the position of the pressure sore because of casting displacement clinically. The large sensor will detect the incorrect pressure value due to wrinkles without close to arm. Hence, we developed a simulated arm with physiological sensors combined with an APP and a cloud storage system to detect skin pressure in real time when applying a short arm cast or splint.
View Article and Find Full Text PDFCast fixation is a general clinical skill used for the treatment of fractures. However, it may cause many complications due to careless treatment procedures. Currently, swathing a cast for a patient can only be determined by a doctors' experience; however, this cannot be determined by the value of pressure, temperature, or humidity with objective and reliable equipment.
View Article and Find Full Text PDFBackground: Patellar malalignment (PM) in most patients is ascribed to an imbalance of peripatellar soft tissue tension.
Research Question: Conservative treatment of PM initially with enforced training of the vastus medialis obliquus (VMO) has been widely applied. Non-operative techniques for treatment of PM require continuing development.
The purpose of this study was to evaluate and quantify the planning performance of SmartArc-based volumetric-modulated arc radiotherapy (VMAT) versus fixed-beam intensity-modulated radiotherapy (IMRT) for nasopharyngeal carcinoma (NPC) using a sequential mode treatment plan. The plan quality and performance of dual arc-VMAT (DA-VMAT) using the Pinnacle3 Smart-Arc system (clinical version 9.0; Philips, Fitchburg, WI, USA) were evaluated and compared with those of seven-field (7F)-IMRT in 18 consecutive NPC patients.