Background: Residual pain is an important cause of patient dissatisfaction after total knee arthroplasty (TKA). A recent study at our institution found that a modern prosthesis was associated with less residual and anterior knee pain at 2-year follow-up when compared to its predecessor. The aim of this study is to evaluate these implants at 5-year follow-up.
View Article and Find Full Text PDFBackground: Pelvic axial rotation affects the functional orientation of an acetabular component. Every 1° of axial rotation changes functional acetabular anteversion by 1°. There is limited information on pelvic rotation in THA patients, since it is difficult to measure on routine radiographs.
View Article and Find Full Text PDFBackground: Cultural differences between continents may also affect the outcome on interventions. This study compared an Asian and North American cohort of total knee replacement (TKR) patients.
Questions/purposes: This study aims to compare the patient-reported outcome measures as well as a functional outcome after TKR between these two different patient populations with a different cultural societal background in two different countries.
Background: Anterior knee pain (AKP) remains a complex issue affecting patient satisfaction after total knee arthroplasty. Several radiographic parameters have been shown to be causative factors with various designs. The aim of this study is to evaluate the known radiographic parameters of AKP and clinical outcomes (ie, AKP) in the setting of a modern prosthesis with an anatomic patella button.
View Article and Find Full Text PDFHeterotopic ossification (HO) is prevalent after total hip arthroplasty (THA). Oral nonsteroidal anti-inflammatory drugs and cyclooxygenase-2 (COX-2) inhibitors have reduced the incidence of HO; however, to the authors' knowledge, no studies have reported the incidence and severity of HO with a pain protocol highlighted by celecoxib in the pre- and postoperative period with a posterolateral approach. Between October 2014 and October 2015, a retrospective study was conducted of 687 consecutive primary THAs with minimum 1-year follow-up performed between January 2009 and December 2013.
View Article and Find Full Text PDFBackground: Bearing surface wear and osteolysis are major factors limiting the durability of total hip arthroplasty (THA). Second generation annealed highly cross-linked polyethylene (HXLPE) and ceramics were introduced to THA for their excellent wear rates. However, there is little data comparing the wear rates of metal and ceramic heads on second generation HXLPE.
View Article and Find Full Text PDFBackground: Concerns persist regarding the oxidative stability of annealed highly cross-linked polyethylene (HXLPE) and hence its wear performance especially long term in young and active patients. The purpose of this study is to assess the wear rates and clinical outcomes of a first-generation annealed HXLPE.
Methods: Forty-six patients (57 hips) with noncemented fixation, a mean age of 53 years, and a mean University of California Los Angeles activity score of 8 underwent primary total hip arthroplasty.
Background: The severity and location of adverse local tissue reaction (ALTR) seen in metal-on-polyethylene total hip arthroplasty (THA) is not well described.
Methods: We retrospectively reviewed the records of patients who underwent a revision THA using our biomechanics database. We included all patients who underwent revision surgery for the diagnosis of ALTR with THA implants that had modularity solely at the head-neck junction and excluded patients with implant modularity at sites other than the head-neck junction.
Background: Anterior knee pain (AKP) and/or crepitation are important causes of dissatisfaction after total knee arthroplasty (TKA). Aim of this prospective, matched-pair study was to compare 2 different designs of patellofemoral (ie, trochlear groove) TKA. The Attune knee has an anatomic trochlear groove with a medialized dome patellar component vs the PFC Sigma with a single radius trochlear groove with a domed shaped patella.
View Article and Find Full Text PDFBackground: In recent time, metal ion debris and adverse local tissue reaction have reemerged as an area of clinical concern with the use of large femoral heads after total hip arthroplasty (THA).
Methods: Between June 2014 and January 2015, 60 patients with a noncemented THA using a titanium (titanium, molybdenum, zirconium, and iron alloy) femoral stem and a V40 trunnion were identified with a minimum 5-year follow-up. All THAs had a 32- or 36-mm metal (n = 30) or ceramic (n = 30) femoral head coupled with highly cross-linked polyethylene.
Background: The presence of hand osteoarthritis (OA) increases the risk for developing OA in other major joints. Although genetic predisposition has been implicated in its causation, its exact role has yet to be established. The association of hand OA with symptomatic and asymptomatic major joints has not been previously studied.
View Article and Find Full Text PDFThis study assessed the efficacy of highly porous cups in revision total hip arthroplasty for Paprosky types II and III acetabular bone loss. The authors identified 33 acetabular revisions in 29 patients from a prospective database (66% type III, 7 with pelvic dissociation). Initial stability was achieved with interference fit between the anterior inferior iliac spine, pubis, and ischium with cups that were 2 to 4 mm larger than the reamed acetabulum and augmented with multiple screw fixations without allograft or wedges.
View Article and Find Full Text PDFBackground: The aim of this study was to evaluate long-term quality and performance of cemented posterior-stabilized (PS) total knee arthroplasty (TKA) in young and active patients with gap balancing technique.
Methods: Between January 2000 and October 2001, 55 TKAs (21 rotating platform [RP] and 34 fixed bearing [FB]) in 41 patients, 60 years and younger, with University of California Los Angeles (UCLA) activity score of five and above were included in this study and prospectively followed. Clinical assessments included Western Ontario and McMaster Universities (WOMAC), Knee Society, UCLA activity score, and Patient Administered Questionnaire (PAQ).
The survivorship of total hip arthroplasty in younger patients is dependent on the wear characteristics of the bearing surfaces. Long-term results with conventional polyethylene in young patients show a high failure rate. This study assessed the long-term results of a first-generation annealed highly cross-linked polyethylene (HCLPE) in uncemented total hip arthroplasty in young, active patients.
View Article and Find Full Text PDFAlthough total knee arthroplasty is a successful and cost-effective procedure, patient dissatisfaction remains as high as 50%. Postoperative residual knee pain after total knee arthroplasty, with or without crepitation, is a major factor that contributes to patient dissatisfaction. The most common location for residual pain after total knee arthroplasty is anteriorly.
View Article and Find Full Text PDFBackground: The effect of fixed spinal deformities on a functional pelvis from standing to sitting is not fully understood. We aimed to assess the change in preoperative sagittal pelvic tilt angle (SPTA) from standing to sitting in patients undergoing total hip arthroplasty, comparing flexible and fixed spinal deformities.
Methods: Between July 2011 and October 2011, 68 consecutive unilateral total hip arthroplasties were implanted in 68 patients with a mean age of 71 ± 6 years.
The purpose of this study was to assess the durability of a non-cemented, hemispherical rim-fit, hydroxyapatite coated cup with a highly cross-linked polyethylene in 223 total hip arthroplasties. At 6-years follow-up (range, 5-9), there were no cup revisions for osteolysis or loosening. Radiologic evidence of osseointegration was based on presence of Stress Induced Reactive Cancellous Bone and radial trabeculae, seen in 47% and 93% of cups, respectively; both were most prevalent in Zone 1.
View Article and Find Full Text PDFJ Bone Joint Surg Am
May 2015
Rotating platforms were introduced as an alternative to fixed bearings in hopes of providing more natural kinematics and improved clinical outcomes. In-vitro wear studies showed significantly less wear with rotating platforms as opposed to fixed-bearing designs. Kinematic follow-up studies showed significantly improved axial rotation with rotating-platform knees.
View Article and Find Full Text PDFThe use of tapered, fluted, modular, distally fixing stems has increased in femoral revision surgery. The goal of this retrospective study was to assess mid-term to long-term outcomes of this implant. Seventy-one hips in 70 patients with a mean age of 69 years were followed for an average of 10 years.
View Article and Find Full Text PDFBackground: A high hip center total hip arthroplasty (THA) for dysplasia allows more complete socket coverage by native bone at the expense of abnormal hip biomechanics. Despite poor results with cemented components, intermediate-term results with cementless cups at a high hip center have been promising, but there are few reports at long-term followup without bone graft.
Questions/purposes: The purpose of this study was to examine (1) survivorship; 2) radiographic results; and 3) hip scores at a minimum of 10 years for patients treated with high hip center cementless THA for Crowe II and III dysplasia without bone graft.
Background: Ceramic femoral heads produce less wear of the opposing polyethylene than do metal femoral heads in wear simulation studies. This is a matched-pair analysis of the wear of ceramic and metal femoral heads on conventional polyethylene in uncemented total hip replacements in young, active patients at a minimum of fifteen years of follow-up.
Methods: From June 1989 to May 1992, thirty-one matched pairs of alumina ceramic or cobalt-chromium metal femoral heads were identified.
Background: Optimal femoral component rotational alignment in total knee arthroplasty (TKA) is crucial to establish a balanced knee reconstruction. Unbalanced knees can lead to instability, patellofemoral problems, persistent pain, stiffness, and generally poorer outcomes including early failure. Intraoperative techniques to achieve this optimal femoral component rotation include the use of the transepicondylar axis (TEA), the posterior-condylar-cut-parallel-to-the-tibial-cut (PCCPTC) technique and the anteroposterior axis technique (Whiteside's line).
View Article and Find Full Text PDFThis is the first long-term (mean 11.6 years), prospective, matched-pair study (based on age, gender, BMI and UCLA scores) using MAVRIC (multi-acquisition variable-resonance image combination) magnetic resonance imaging to analyze reactive synovitis and osteolysis between rotating-platform posterior-stabilized (RP-PS), fixed-bearing metal-back (FB-MB), and all-polyethylene tibial (APT) in active patients (24 total, 8 in each group, mean age of 64 years, mean UCLA of 8.5) with identical femoral component and polyethylene.
View Article and Find Full Text PDFThe aim of this study was to assess peri-operative complications, safety and efficacy of non-cemented femoral fixation in total hip arthroplasty (THA) as compared to cemented femoral fixation in the elderly population. Fifty-two matched pair analysis of patients with 75 years of age and older (104 patients), who underwent primary THA from June 1997 to December 2004, was performed based on age, sex, BMI, and Charnley classification. Mean age was 81 years (75-101) and the average follow up was 3.
View Article and Find Full Text PDF