Publications by authors named "Ching-Lung Tai"

Background: Pediatric supracondylar humeral fractures present considerable surgical challenges due to the difficulty of achieving proper fracture alignment and stable fixation while avoiding injury to the ulnar nerve. This study assesses the biomechanical performance of a novel Kirschner wire (K-wire) fixation device (KFD), designed to enhance stability and reduce complications linked to traditional K-wire configurations.

Methods: Using finite element analysis (FEA), we evaluated four fixation strategies for treatment of pediatric supracondylar humeral simple transverse fractures: crossed pin fixation, crossed pin fixation with KFD, two lateral pin fixation, and two lateral pin fixation with KFD, under various mechanical loads.

View Article and Find Full Text PDF

Background Context: Long-segment pedicle screw instrumentation is widely used to treat complex spinal disorders. Rods are routinely precontoured to maximize assistance on the correcting side of the deformity, but there often exists a residual gap discrepancy between the precontoured rods and screw tulips. No previous research has investigated the diminished pullout strength of the most proximal or distal pedicle screw resulting from a mismatched rod in long-segment pedicle screw instrumentation.

View Article and Find Full Text PDF

Despite advancements in pedicle screw design and surgical techniques, the standard steps for inserting pedicle screws still need to follow a set of fixed procedures. The first step, known as establishing a pilot hole, also referred to as a pre-drilled hole, is crucial for ensuring screw insertion accuracy. In different surgical approaches, such as minimally invasive or traditional surgery, the method of creating pilot holes varies, resulting in different pilot hole profiles, including variations in size and shape.

View Article and Find Full Text PDF

Ball-and-socket designs of cervical total disc replacement (TDR) have been popular in recent years despite the disadvantages of polyethylene wear, heterotrophic ossification, increased facet contact force, and implant subsidence. In this study, a non-articulating, additively manufactured hybrid TDR with an ultra-high molecular weight polyethylene core and polycarbonate urethane (PCU) fiber jacket, was designed to mimic the motion of normal discs. A finite element (FE) study was conducted to optimize the lattice structure and assess the biomechanical performance of this new generation TDR with an intact disc and a commercial ball-and-socket BagueraC TDR (Spineart SA, Geneva, Switzerland) on an intact C5-6 cervical spinal model.

View Article and Find Full Text PDF

Intraoperative pedicle screw depth adjustment after initial insertion, including both forward and backward adjustments, is sometimes necessary to facilitate rod application and ensure that the screw is in the correct position, which is determined by intraoperative fluoroscopy. Adjusting the screw with forward turns has no negative influence on the screw fixation stability; however, screw turnback may weaken the fixation stability. The aim of this study is to evaluate the biomechanical properties of screw turnback and demonstrate the reduction in the fixation stability after the screw is turned 360° from its full insertion position.

View Article and Find Full Text PDF

Although an anterior approach with anterior lateral screw fixation has been developed for stabilizing the thoracolumbar spine clinically, screw loosening still occurs. In this novel in vitro study, we attempted to elucidate the optimal screw position in the lateral lumbar vertebra and the effect of bicortical fixation. A total of 72 fresh-frozen lumbar vertebrae from L1-6 were harvested from 12 mature pigs and randomly assigned to two modalities: bicortical fixation (n = 36) and unicortical fixation (n = 36).

View Article and Find Full Text PDF

Three key factors are responsible for the biomechanical performance of pedicle screw fixation: screw mechanical characteristics, bone quality and insertion techniques. To the best of the authors' knowledge, no study has directly compared the biomechanical performance among three trajectories, i.e.

View Article and Find Full Text PDF

Background Context: Pedicle screw-rod assembly procedures following pedicle screw insertion include contouring and placing rods into screw tulips, introducing set screws into the tulip along the screw thread, applying a counter-torque holder and tightening all the set screws clockwise. Even if an appropriate pedicle screw is implanted, screw dislodgement after tightening of the tulip and set screw is not uncommon. Pedicle wall violation resulting from excessive rotational force due to inadequate use of a counter-torque holder might be the reason.

View Article and Find Full Text PDF

Pedicle screw fixation is one of the most common procedures used in spinal fusion surgery. The screw loosening is a major concern, which may be caused by broken pedicles. In vitro pullout tests or insertion torque are the main approaches for assessing the stability of the screw; however, direct evidence was lacking for clinical human spines.

View Article and Find Full Text PDF

Polymethylmethacrylate (PMMA) has been applied clinically and biomechanically repair loose pedicle screws. Controversies have arisen over data due to uncontrolled cement properties, various locations and sizes of fenestrated holes in repair screws, irregular holes and different bone densities of specimens. In this study, the pullout strength was compared for two techniques, the modified technique to use PMMA to augment a threaded hole and the traditional technique with retrograde injection of a PMMA filling, for standard loose screws in porcine vertebrae.

View Article and Find Full Text PDF

Osteoporosis is a critical problem during aging. Ultrasound signals backscattered from bone contain information associated with microstructures. This study proposed using entropy imaging to collect the information in bone microstructures as a possible solution for ultrasound bone tissue characterization.

View Article and Find Full Text PDF

Study Design: Biomechanical study.

Objective: Cross-links are a type of common clinical spinal instrumentation. However, the effects of the position and number of cross-links have never been investigated in long-segment spinal fixation, and the variables have not been optimized.

View Article and Find Full Text PDF

Screw loosening due to broken pedicles is a common complication resulting from the insertion of screws either with inadequate diameters or into an osteoporotic pedicle. In this novel in vitro study, we tried to clarify the contribution of the pedicle to screw fixation and subsequent salvage strategies using longer or larger-diameter screws in broken pedicles. Sixty L4 fresh-frozen lumbar vertebrae harvested from mature pigs were designed as the normal-density group (n = 30) and decalcified as the osteoporosis group (n = 30).

View Article and Find Full Text PDF

Pedicle screw loosening resulting from insufficient bone-screw interfacial holding power is not uncommon. The screw shape and thread profile are considered important factors of the screw fixation strength. This work investigated the difference in pullout strength between conical and cylindrical screws with three different thread designs.

View Article and Find Full Text PDF

Pedicles are often broken when screws are inserted into hard pedicles with small diameters or when the diameter of the screw itself is inadequate. However, there is a lack of biomechanical literature that addresses screw loosening as a result of broken pedicles or the resulting salvage of those screws. We performed a novel in vitro study to compare the pullout strength of screws between intact pedicles and two different types of broken pedicles; strategies to prevent screw loosening were also compared.

View Article and Find Full Text PDF

Background: Adolescent idiopathic scoliosis, in which obvious curves are visible in radiographic images, is also seen in combination with lumps in the back. These lumps contribute to inclination, which can be measured by a scoliometer. To the authors' knowledge, there are no previous formulas combining thoracic and lumbar scoliometer values simultaneously to predict thoracic and lumbar Cobb angles, respectively.

View Article and Find Full Text PDF
Article Synopsis
  • Rat caudal discs are ideal for studying interbody fusion due to their similarity to human discs in structure and function.
  • In a study with female Sprague-Dawley rats, researchers performed interbody fusion and evaluated the results through radiological, histological assessments, and mechanical testing.
  • The findings showed successful fusion with significant bone formation and increased bending stiffness in fused segments, confirming the model's effectiveness for future research on fusion treatments.
View Article and Find Full Text PDF

Osteoporosis is a bone disease that afflicts millions of people around the world, and a variety of spinal integrity issues, such as degenerative spinal stenosis and spondylolisthesis, are frequently concomitant with osteoporosis and are sometimes treated with spinal interbody fusion surgery. Previous studies have demonstrated the efficacy of strontium ranelate (SrR) treatment of osteoporosis in improving bone strength, promoting bone remodeling, and reducing the risk of fractures, but its effects on interbody fusion surgery have not been adequately investigated. SrR-treated rats subjected to interbody fusion surgery exhibited significantly higher lumbar vertebral bone mineral density after 12 weeks of treatment than rats subjected to the same surgery but not treated with SrR.

View Article and Find Full Text PDF

Antibiotic-loaded bone cement (ALBC) is widely used in orthopaedic surgery for both prevention and treatment of infection. Little is known about the effect of different brand combinations of antibiotic and bone cement on the elution profile and mechanical strength of ALBC. Standardized specimens that consisted of one of the 4 brands of bone cement and one of the 3 brands of vancomycin were fashioned, producing 12 combinations of ALBC.

View Article and Find Full Text PDF

Polymethylmethacrylate (PMMA) bone cement is a popular bone void filler for vertebroplasty. However, the use of PMMA has some drawbacks, including the material's excessive stiffness, exothermic polymerization, and short handling time. This study aimed to create an ideal modified bone cement to solve the above-mentioned problems.

View Article and Find Full Text PDF

Purpose: Distal femur fractures adjacent to total knee arthroplasty are a rare yet complex problem. Recently, extramedullary locking plate and retrograde intramedullary nail fixations have become popular options, but the complication rates associated with these procedures are 15-20 %. Modified fixations were assessed in an effort to reduce complications from unstable periprosthetic fractures.

View Article and Find Full Text PDF

Expansive pedicle screws significantly improve fixation strength in osteoporotic spines. However, the previous literature does not adequately address the effects of the number of lengthwise slits and the extent of screw expansion on the strength of the bone/screw interface when expansive screws are used with or without cement augmentation. Herein, four designs for expansive pedicle screws with different numbers of lengthwise slits and different screw expansion levels were evaluated.

View Article and Find Full Text PDF

Unlabelled: An absolutely convincing technique of anterior transfer of the tibialis posterior (TP) tendon for treating drop foot has not been developed. Thirty-seven consecutive adult patients with drop foot owing to deep peroneal nerve injury were treated with bone-to-bone TP tendon transfer. The TP tendon with a small bony attachment was procured from the undersurface of the navicula and then transferred through a tunnel of the interosseous membrane.

View Article and Find Full Text PDF

Background: Acetabular reinforcement devices (ARDs) are frequently used as load-sharing devices to allow allograft incorporation in revision hip arthroplasty with massive acetabular bone loss. The key to a successful reconstruction is robust fixation of the device to the host acetabulum. Interlocking fixation is expected to improve the initial stability of the postoperative construct.

View Article and Find Full Text PDF

Background: Due to the advantages of its bone-conserving nature, hip resurface arthroplasty (HRA) has recently gained the interest of orthopedic surgeons for the treatment of young and active patients who have osteonerosis of the femoral head. However, in long-term follow-up studies after HRA, narrowing of the femoral neck has often been found, which may lead to fracture. This phenomenon has been attributed to the stress alteration (stress shielding).

View Article and Find Full Text PDF