Purpose: To establish an ultra-high dose-rate (UHDR) radiation system using a synchrotron proton beam accelerator and to compare the effects by irradiation positions on cultured cells and chick embryos.

Methods And Materials: Protons for UHDR were obtained by applying high-frequency power at much higher levels than usual to extract all protons within approximately 50 ms. Subsequently, monitoring with a Faraday cup was performed immediately after synchrotron extraction and the waveform was adjusted accordingly.

View Article and Find Full Text PDF

A radiophotoluminescent glass dosimeter (RGD) is used for a postal audit of a photon beam because of its various excellent characteristics. However, it has not been used for scanning proton beams because its response characteristics have not been verified. In this study, the response of RGD to scanning protons was investigated to develop a dosimetry protocol using the linear energy transfer (LET)-based correction factor.

View Article and Find Full Text PDF

Purpose: The present study investigated the biological effects of spot scanning and passive scattering proton therapies at the distal end region of the spread-out Bragg peak (SOBP) using single cell and multicell spheroids.

Materials And Methods: The Geant4 Monte Carlo simulation was used to calculate linear energy transfer (LET) values in passive scattering and spot scanning beams. The biological doses of the two beam options at various points of the distal end region of SOBP were investigated using EMT6 single cells and 0.

View Article and Find Full Text PDF

A radiophotoluminescent glass dosimeter (RGD) is widely used in postal audit system for photon beams in Japan. However, proton dosimetry in RGDs is scarcely used owing to a lack of clarity in their response to beam quality. In this study, we investigated RGD response to beam quality for establishing a suitable linear energy transfer (LET)-corrected dosimetry protocol in a therapeutic proton beam.

View Article and Find Full Text PDF

The purpose of the current study was to investigate the biological effects of protons and photons in combination with cisplatin in cultured cells and elucidate the mechanisms responsible for their combined effects. To evaluate the sensitizing effects of cisplatin against X-rays and proton beams in HSG, EMT6 and V79 cells, the combination index, a simple measure for quantifying synergism, was estimated from cell survival curves using software capable of performing the Monte Carlo calculation. Cell death and apoptosis were assessed using live cell fluorescence imaging.

View Article and Find Full Text PDF

The clinical superiority of proton therapy over photon therapy has recently gained recognition; however, the biological effects of proton therapy remain poorly understood. The lack of in vivo evidence is especially important. Therefore, the goal of this study was to validate the usefulness of Drosophila melanogaster as an alternative tool in proton radiobiology.

View Article and Find Full Text PDF

The clinical superiority of proton therapy over photon therapy has recently gained recognition; however, the biological effects of proton therapy remain poorly understood. The lack of evidence is especially important. Therefore, the goal of this study was to validate the usefulness of as an alternative tool in proton radiobiology.

View Article and Find Full Text PDF

To investigate optimal treatment planning using proton beams for non-squamous cell carcinoma of the head and neck (NSCHN), the dose distributions of plans involving pencil beam scanning (PBS) with or without a patient-specific aperture system (PSAS), passive-scattering proton therapy (PSPT) and X-ray intensity-modulated radiotherapy (IMRT) were compared. As clinical results, toxicities of PBS with PSAS, including changes in quality of life, were reported. Between April 2014 and August 2016, a total of 30 patients were treated using PBS with PSAS.

View Article and Find Full Text PDF

The purpose of this study was to propose a verification method and results of intensity-modulated proton therapy (IMPT), using a commercially available heterogeneous phantom. We used a simple simulated head and neck and prostate phantom. An ionization chamber and radiochromic film were used for measurements of absolute dose and relative dose distribution.

View Article and Find Full Text PDF

In this study, we evaluate dosimetric advantages of using patient-specific aperture system with intensity-modulated proton therapy (IMPT) for head and neck tumors at the shallow depth. We used four types of patient-specific aperture system (PSAS) to irradiate shallow regions less than 4 g/cm with a sharp lateral penumbra. Ten head and neck IMPT plans with or without aperture were optimized separately with the same 95% prescription dose and same dose constraint for organs at risk (OARs).

View Article and Find Full Text PDF

Purpose: In order to clarify the biological response of tumor cells to proton beam irradiation, sublethal damage recovery (SLDR) and potentially lethal damage recovery (PLDR) induced after proton beam irradiation at the center of a 10 cm spread-out Bragg peak (SOBP) were compared with those seen after X‑ray irradiation.

Methods: Cell survival was determined by a colony assay using EMT6 and human salivary gland tumor (HSG) cells. First, two doses of 4 Gy/GyE (Gray equivalents, GyE) were given at an interfraction interval of 0-6 h.

View Article and Find Full Text PDF

To measure the absorbed dose to water D in proton beams using a radiophotoluminescent glass dosimeter (RGD), a method with the correction for the change of the mass stopping power ratio (SPR) and the linear energy transfer (LET) dependence of radiophotoluminescent efficiency [Formula: see text] is proposed. The calibration coefficient in terms of D for RGDs (GD-302M, Asahi Techno Glass) was obtained using a Co γ-ray. The SPR of water to the RGD was calculated by Monte Carlo simulation, and [Formula: see text] was investigated experimentally using a 70 MeV proton beam.

View Article and Find Full Text PDF

The purpose of this paper is to describe an outline of a proton therapy system in Nagoya Proton Therapy Center (NPTC). The NPTC has a synchrotron with a linac injector and three treatment rooms: two rooms are equipped with a gantry and the other one is equipped with a fixed horizontal beamline. One gantry treatment room has a pencil beam scanning treatment delivery nozzle.

View Article and Find Full Text PDF

Purpose: To determine the relative biological effectiveness (RBE), oxygen enhancement ratio (OER), and contribution of the indirect effect of spot scanning proton beams, passive scattering proton beams, or both in cultured cells in comparison with clinically used photons.

Methods And Materials: The RBE of passive scattering proton beams at the center of the spread-out Bragg peak (SOBP) was determined from dose-survival curves in 4 cell lines using 6-MV X rays as controls. Survival of 2 cell lines after spot scanning and passive scattering proton irradiation was then compared.

View Article and Find Full Text PDF

Purpose: The main purpose in this study was to present the results of beam modeling and how the authors systematically investigated the influence of double and triple Gaussian proton kernel models on the accuracy of dose calculations for spot scanning technique.

Methods: The accuracy of calculations was important for treatment planning software (TPS) because the energy, spot position, and absolute dose had to be determined by TPS for the spot scanning technique. The dose distribution was calculated by convolving in-air fluence with the dose kernel.

View Article and Find Full Text PDF

Purpose: In the authors' proton therapy system, the patient-specific aperture can be attached to the nozzle of spot scanning beams to shape an irradiation field and reduce lateral fall-off. The authors herein verified this system for clinical application.

Methods: The authors prepared four types of patient-specific aperture systems equipped with an energy absorber to irradiate shallow regions less than 4 g/cm(2).

View Article and Find Full Text PDF