IEEE Trans Biomed Circuits Syst
August 2024
Hand-held ultrasound devices have been widely used in the field of healthcare and power-efficient, real-time imaging is essential. This work presents the world's first ultrasound imaging processor supporting advanced modes, including vector flow imaging and elastography imaging. Plane-wave beamforming is utilized to ensure that the pulse repetition frequency (PRF) is sufficiently high for the advanced mode.
View Article and Find Full Text PDFBackground/purpose: We investigated the diagnostic performance of the anal sphincter relaxation integral (ASRI) for infants with Hirschsprung's disease (HD).
Methods: We performed water-perfused high-resolution anorectal manometry (HRAM) in 18 infants (9 with HD), and solid-state HRAM in another 18 infants (4 with HD). We calculated the ASRI during the rectoanal inhibitory reflex (RAIR) maneuver at pressure cutoffs of <10 mmHg (ASRI 10) and <15 mmHg (ASRI 15).
IEEE Trans Biomed Circuits Syst
December 2023
This article presents an Ferragina-Manzini index (FM-index) based paired-end short-read mapping hardware accelerator. Four techniques are proposed to significantly reduce the number of memory accesses and operations to improve the throughput. First, an interleaved data structure is proposed to reduce the processing time by 51.
View Article and Find Full Text PDFIEEE J Biomed Health Inform
November 2022
Automatic assessment of sleep apnea/ hypopnea syndrome (SAHS) based on fewer physiological signals is critical for the success of healthcare at home. However, previous studies that use such settings only achieve a lower assessment accuracy, causing fewer syndromes to be separated for effective diagnosis. This paper presents a 3-stage support vector machines (SVM)-based algorithm for SAHS assessment using a single-channel nasal pressure (NP) signal.
View Article and Find Full Text PDFLaryngopharyngeal reflux symptom is a troublesome upper esophageal problem, and reflux symptom index (RSI) is commonly applied for the assessment of clinical severity. We investigated the relationship between the upper esophageal sphincter impedance integral (UESII) and RSI scores in this study. Totally 158 subjects with high-resolution esophageal impedance manometry (HRIM) with RSI questionnaire assessment were recruited.
View Article and Find Full Text PDFBackground And Aim: We elucidated the clinical significance of distal contractile integral-to-esophageal impedance integral (EII) ratio (DCIIR) in ineffective esophageal motility (IEM) adult patients.
Methods: We recruited 101 patients with IEM (48.38 ± 1.
Objective: To develop and verify a CMOS bone-guided cochlear implant (BGCI) microsystem with electrodes placed on the bone surface of the cochlea and the outside of round window for treating high-frequency hearing loss.
Methods: The BGCI microsystem consists of an external unit and an implanted unit. The external system-on-chip is designed to process acoustic signals through an acquisition circuit and an acoustic DSP processor to generate stimulation patterns and commands that are transmitted to the implanted unit through a 13.
Objectives: We investigated the diagnostic utility of distal contractile integral (DCI) to esophageal impedance integral (EII) ratio (DCIIR) in high-resolution impedance manometry (HRIM) of ineffective esophageal motility (IEM) in children.
Methods: We performed HRIM in 31 children with dysphagia, odynophagia, chronic vomiting, chest pain, or heartburn sensation. Based on the Chicago classification version 3.
IEEE Trans Biomed Circuits Syst
December 2017
Next-generation sequencing (NGS) enables high-throughput sequencing, in which short DNA fragments can be sequenced in a massively parallel fashion. However, the essential algorithm behind the succeeding NGS data analysis, DNA mapping, is still excessively time consuming. DNA mapping can be partitioned into two parts: suffix array (SA) sorting and backward searching.
View Article and Find Full Text PDFObjective: To investigate the possible diagnostic role of anal sphincter relaxation integral (ASRI) in high-resolution anorectal manometry (HRAM) for Hirschsprung disease.
Study Design: We performed conventional anorectal manometry (ARM) in 24 infants (8 with Hirschsprung disease and 16 without Hirschsprung disease) and HRAM in another 21 infants (9 with Hirschsprung disease and 12 without Hirschsprung disease) before and after October 2014. All infants underwent rectal suction biopsy for confirmation of Hirschsprung disease.
Motivation: The Full-text index in Minute space (FM-index) derived from the Burrows-Wheeler transform (BWT) is broadly used for fast string matching in large genomes or a huge set of sequencing reads. Several graphic processing unit (GPU) accelerated aligners based on the FM-index have been proposed recently; however, the construction of the index is still handled by central processing unit (CPU), only parallelized in data level (e.g.
View Article and Find Full Text PDFIEEE Trans Biomed Circuits Syst
December 2014
IEEE Trans Biomed Circuits Syst
February 2015
To improve the performance of epileptic seizure detection, independent component analysis (ICA) is applied to multi-channel signals to separate artifacts and signals of interest. FastICA is an efficient algorithm to compute ICA. To reduce the energy dissipation, eigenvalue decomposition (EVD) is utilized in the preprocessing stage to reduce the convergence time of iterative calculation of ICA components.
View Article and Find Full Text PDFObjective: Around 1% of the world's population is affected by epilepsy, and nearly 25% of patients cannot be treated effectively by available therapies. The presence of closed-loop seizure-triggered stimulation provides a promising solution for these patients. Realization of fast, accurate, and energy-efficient seizure detection is the key to such implants.
View Article and Find Full Text PDF