Introduction: In 2017, the Ministry of Health and Public Hygiene (MoH) of Burkina Faso designed and piloted a specimen transport system using the national courier services (La Poste BF) in 4 districts. Based on satisfactory performance indicators, the MoH set a vision aimed at scaling up this system to strengthen disease detection and surveillance of epidemic prone diseases across the country. This work describes the implementation process, performances, and lessons learned.
View Article and Find Full Text PDFBackground: Standardising procedures is the best way to harmonise and strengthen the quality of laboratory-based antimicrobial resistance surveillance. Since 2018, Burkina Faso has developed and disseminated the national manual of procedures for performing antibiotic susceptibility tests in sentinel laboratories within its national antimicrobial resistance surveillance network.
Objective: Our study aimed to assess these sentinel laboratories' compliance with good practices for antibiotics susceptibility tests.
Background: The aim of this study was to evaluate the performance of ten (10) SARS-CoV-2 serological rapid diagnostic tests in comparison with the WANTAI SARS-CoV-2 Ab ELISA test in a laboratory setting.
Materials And Methods: Ten (10) SARS-CoV-2 serological rapid diagnostic tests (RDTs) for SARS-CoV-2 IgG/IgM were evaluated with two (2) groups of plasma tested positive for one and negative for the other with the WANTAI SARS-CoV-2 Ab ELISA. The diagnostic performance of the SARS-CoV-2 serological RDTs and their agreement with the reference test were calculated with their 95% confidence intervals.
The Global Health Security Agenda and the International Health Regulations (2005) recommend that countries strengthen the capacity of their national laboratory systems to comply with the International Health Regulations. To efficiently and effectively direct these efforts, the US Centers for Disease Control and Prevention-in collaboration with the Ministry of Health Directorate of Laboratories, the African Society for Laboratory Medicine, and Integrated Quality Laboratory Service-assessed Burkina Faso's national laboratory system using the World Health Organization . Based on gaps observed in biorisk management, the Biosafety and Biosecurity Laboratory Assessment Tool (BSS LAT) was developed to assess 10 public laboratories handling dangerous pathogens.
View Article and Find Full Text PDFObjectives: The National External Quality Assessment (NEQA) program of Burkina Faso is a proficiency testing program mandatory for all laboratories in the country since 2006. The program runs two cycles per year and covers all areas of laboratories.
Methods: All panels were validated by the expert committee before dispatch under optimal storage and transport conditions to participating laboratories along with report forms.
MenAfriVac™ is a new meningococcal A conjugate vaccine developed to prevent meningitis outbreaks in Africa. It was first introduced during the last quarter of 2010 in three West African countries. We report on the monitoring of adverse events following immunization (AEFI) in Burkina Faso where more than 11 million people aged 1-29 years were vaccinated.
View Article and Find Full Text PDFWe report results of the National External Quality Assessment for (NEQA) laboratories in Burkina Faso, a country with limited resources located in West Africa whose epidemiology is dominated by infectious diseases. The national laboratory network consists of 160 laboratories including 40 private. The Government of Burkina Faso has adopted a national laboratory policy.
View Article and Find Full Text PDF