Background And Aims: For patients with symptomatic, severe tricuspid regurgitation (TR), early results of transcatheter tricuspid valve (TV) intervention studies have shown significant improvements in functional status and quality of life associated with right-heart reverse remodelling. Longer-term follow-up is needed to confirm sustained improvements in these outcomes.
Methods: The prospective, single-arm, multicentre TRISCEND study enrolled 176 patients to evaluate the safety and performance of transcatheter TV replacement in patients with ≥moderate, symptomatic TR despite medical therapy.
The complexity of structural heart interventions has led to a demand for sophisticated periprocedural imaging guidance. Although traditional 2-dimensional (2D) transesophageal techniques are used widely, new-generation 3D ultrasound probes enable high temporal and spatial resolution. Multiplanar reconstruction of acquired 3D datasets has gained considerable momentum for precise imaging and to increase the validity of measurements.
View Article and Find Full Text PDFPurpose Of Review: Mitral valve repair is a common surgical procedure for both primary and secondary mitral regurgitation. With operations performed earlier in disease progression and increased patient longevity, the need for a repeat intervention is not infrequent. With the associated risks of reoperation and patient comorbidities, percutaneous techniques for acute or delayed failure after ring annuloplasty are emerging.
View Article and Find Full Text PDFIntraoperative transesophageal echocardiography is a standard diagnostic and monitoring tool employed in the management of patients undergoing an entire spectrum of cardiac surgical procedures, ranging from "routine" surgical coronary revascularization to complex valve repair, combined procedures, and organ transplantation. Utilizing a protocol as a starting point for imaging in all procedures and all patients enables standardization of image acquisition, reduction in variability in quality of imaging and reporting, and ultimately better patient care. Clear communication of the echocardiographic findings to the surgical team, as well as understanding the impact of new findings on the surgical plan, are paramount.
View Article and Find Full Text PDFObjectives: The aim of this study was to examine whether hospital surgical aortic valve replacement (SAVR) volume was associated with corresponding transcatheter aortic valve replacement (TAVR) outcomes.
Background: Recent studies have demonstrated a volume-outcome relationship for TAVR.
Methods: In total, 208,400 fee-for-service Medicare beneficiaries were analyzed for all aortic valve replacement procedures from 2012 to 2015.
Sex-based differences in outcomes have been shown to affect caregiving in medical disciplines. Increased spending due to postacute care transfer policies has led hospitals to further scrutinize patient outcomes and disposition patterns after inpatient admissions. We examined sex-based differences in rehabilitative service utilization after transcatheter aortic valve implantation (TAVI).
View Article and Find Full Text PDFBackground: A lower rate of permanent pacemaker (PPM) has been linked to a target aortic implantation height (AIH) >0.70, following transcatheter aortic valve replacement (TAVR) with the SAPIEN 3 valve. Based on clinical experience, it was hypothesized that a higher AIH (≥0.
View Article and Find Full Text PDFSemin Cardiothorac Vasc Anesth
March 2019
The advent of percutaneous therapies has significantly altered therapeutic options for patients with valvular heart disease. Building on the success of transcatheter aortic valve replacement, both expanded indications and purpose-built devices are now being used to address percutaneous approaches for mitral valve pathology. While surgical mitral valve repair remains the gold standard for addressing significant mitral valve pathology, there has been a progressive increase in the utilization of bioprosthetic valves despite their limited lifespan.
View Article and Find Full Text PDFRationale And Objectives: The purpose of this study is to compare image quality, presence and grade of artifacts, signal-to-noise ratio, and apparent diffusion coefficient (ADC) values in pancreatic tissue between high-resolution navigator-triggered (NT) restricted field of view (rFOV) FOCUS single-shot (SS) echo-planar imaging (EPI) diffusion-weighted imaging (DWI) and NT large FOV SS-EPI DWI.
Materials And Methods: Magnetic resonance imaging examinations were performed with GE 3-T systems using a 32-channel body array coil. Seventeen consecutive patients were imaged.
Percutaneous intervention for mitral valve (MV) disease has been established as an alternative to open surgical MV repair in patients with prohibitive surgical risk. Multiple percutaneous approaches have been described and are in various stages of development. Edge-to-edge leaflet plication with the MitraClip (Abbott, Menlo Park, CA) is currently the only Food and Drug Administration-approved device specifically for primary or degenerative lesions.
View Article and Find Full Text PDFObjectives: Although the transfemoral approach for transcatheter aortic valve replacement is the preferred choice, alternative access remains indicated for inadequate iliofemoral vessels. We report the successful implementation of a novel fast-track (FT) protocol for patients undergoing alternative access transcatheter aortic valve replacement compared with conventional controls.
Methods: Between September 2014 and January 2017, 31 and 23 patients underwent alternative access transcatheter aortic valve replacement under FT and pre-fast-track (p-FT) protocols, respectively.
Background: We aimed to compare periprocedural transesophageal echocardiography (TEE) with postprocedural transthoracic echocardiography (TTE) for the diagnosis of aortic regurgitation (AR).
Methods And Results: TEE and TTE images of 163 transcatheter aortic valve replacement (TAVR) patients (mean age 81 ± 8 years; 56% men) were reviewed separately and blinded to each other as well as to all clinical data. The median time between TEE during TAVR (TEE/TAVR) and TTE was 4 days (IQR 2-10 days).
Background: The purpose of this multicenter pilot study was to: (1) determine the frequency of regional cerebral oxygen saturation (rScO2) desaturations during cardiac surgery involving cardiopulmonary bypass (CPB); (2) evaluate the accuracy of clinician-identified rScO2 desaturations compared with those recorded continuously during surgery by the near-infrared spectroscopy (NIRS) monitor; and (3) assess the effectiveness of an intervention algorithm for reversing rScO2 desaturations.
Methods: Two hundred thirty-five patients undergoing coronary artery bypass graft and/or valvular surgery were enrolled at 8 US centers in this prospective observational study. NIRS (Invos™ 5100C; Covidien) was used to monitor rScO2 during surgery.
Background: Coagulopathy and massive bleeding are severe complications of cardiac surgery, particularly in procedures requiring prolonged cardiopulmonary bypass (CPB). There is huge variability in transfusion practices across hospitals and providers in cross-sectional studies. This variability may indicate unguided decision-making, perhaps attributable to lack of reliable, predictive laboratory testing of coagulopathy to guide transfusion practice.
View Article and Find Full Text PDF