Surface plasmon polaritons have attracted attention for energy applications such as photovoltaic and photoelectrochemical cells because of their ability to improve optical absorption in thin films. We show that surface plasmon polaritons enhance absorption most significantly in materials with small positive real permittivity and large positive imaginary permittivity, e.g.
View Article and Find Full Text PDFIn this paper, we report on experimental and theoretical studies that investigate how the structural properties of plasmonic nanodome array devices determine their optical properties and sensing performance. We examined the effect of the interdome gap spacing within the plasmonic array structures on the performance for detection of change in local refractive index environment for label-free capture affinity biosensing applications. Optical sensing properties were characterized for nanodome array devices with interdome spacings of 14 nm, 40 nm, and 79 nm, as well as for a device where adjacent domes are in contact.
View Article and Find Full Text PDFThe characteristics and utility of plasmonic nanodome arrays capable of supporting multiple resonance modes are described. A low-cost, large-area replica molding process is used to produce, on flexible plastic substrates, two-dimensional periodic arrays of cylinders that are subsequently coated with SiO2 and Ag thin films to form dome-shaped structures, with 14 nm spacing between the features, in a precise and reproducible fashion. Three distinct optical resonance modes, a grating diffraction mode and two localized surface plasmon resonance (LSPR) modes, are observed experimentally and confirmed by finite-difference-time-domain (FDTD) modeling which is used to calculate the electromagnetic field distribution of each resonance around the nanodome array structure.
View Article and Find Full Text PDFThe optical properties and surface-enhanced Raman scattering (SERS) of plasmonic nanodome array (PNA) substrates in air and aqueous solution are investigated. PNA substrates are inexpensively and uniformly fabricated with a hot spot density of 6.25 × 10(6) mm(-2) using a large-area nanoreplica moulding technique on a flexible plastic substrate.
View Article and Find Full Text PDFIn medical facilities, there is strong motivation to develop detection systems that can provide continuous analysis of fluids in medical tubing used to either deliver or remove fluids from a patient's body. Possible applications include systems that increase the safety of intravenous (IV) drug injection and point-of-care health monitoring. In this work, we incorporated a surface-enhanced Raman scattering (SERS) sensor comprised of an array of closely spaced metal nanodomes into flexible tubing commonly used for IV drug delivery and urinary catheters.
View Article and Find Full Text PDFWe demonstrate a surface-enhanced Raman scattering (SERS) substrate consisting of a closely spaced metal nanodome array fabricated on flexible plastic film. We used a low-cost, large-area replica molding process to produce a two-dimensional periodic array of cylinders that is subsequently overcoated with SiO(2) and silver thin films to form dome-shaped structures. Finite element modeling was used to investigate the electromagnetic field distribution of the nanodome array structure and the effect of the nanodome separation distance on the electromagnetic field enhancement.
View Article and Find Full Text PDFUsing both experimental assays and fluid-dynamic finite element simulation models, we directly compared the achievable performance limits of four distinct assay configurations for label-free detection of an analyte from a test sample on a biosensor surface. The assay configurations studied in this work included a biosensor incorporated into the bottom surface of a microplate well and a microfluidic channel. For each configuration, we compared assay performance for the scenario in which the entire bottom surface of the fluid-handling vessel is coated with capture ligands with assay performance for the scenario in which the capture ligands are applied in the form of localized spots.
View Article and Find Full Text PDFThis paper reports the design, fabrication and validation of a microfluidic well plate for combinatorial screening applications. Each well within the array is comprised of two 200 picoliter compartments that each contain a photonic crystal biosensor to enable the on-chip, in situ detection of (bio-) molecular binding events. This microfluidic chip utilizes arrays of Actuate-to-Open valves to isolate all compartments, which allows the chip to be decoupled from pneumatic control lines and thus to be transported freely between filling, sensing and characterization platforms.
View Article and Find Full Text PDFA nanoreplica molding process has been used to produce polymer microfluidic channels, with integrated label-free photonic crystal biosensors as the bottom surface of the channels. Multiple flow channels are gathered in parallel so that an imaging detection instrument may simultaneously monitor the binding kinetics of many biomolecular interactions. In this work, the flow channel pattern has been adapted to a 96-well microplate format in which, for each 12-element row of the microplate, a single well serves as a common access port for 11 flow channels that are connected to separate microplate wells.
View Article and Find Full Text PDFA method for simultaneously integrating label-free photonic crystal biosensor technology into microfluidic channels by a single-step replica molding process is presented. By fabricating both the sub-micron features of the photonic crystal sensor structure and the >10 microm features of a flow channel network in one step at room temperature on a plastic substrate, the sensors are automatically self-aligned with the flow channels, and patterns of arbitrary shape may be produced. By measuring changes in the resonant peak reflected wavelength from the photonic crystal structure induced by changes in dielectric permittivity within an evanescent field region near its surface, detection of bulk refractive index changes in the fluid channel or adsorption of biological material to the sensor surface is demonstrated.
View Article and Find Full Text PDF