Background: Various studies have reported good long-term results using femoral stems with either smooth or rough surfaces. In this retrospective cross-sectional survivorship study, we reviewed the 10-year results of 51 bilateral staged cemented total hip arthroplasties using the Harvard or the Charnley femoral stems-which have almost similar geometry but a different surface finish.
Methods: 51 patients were reviewed at median interval of 10 (Harvard group) and 11 years (Charnley group) after the primary operation.
Background: Several cementing techniques are used for the proximal femur.
Material And Methods: We evaluated 3 femoral cement pressurization techniques (standard, pressurizer in situ, and thumb pressurization) in 12 plastic femurs, with 4 sets of observations for each technique. Intramedullary pressure readings were obtained using proximal and distal pressure monitoring transducers.