This work investigates the selectivity and retention changes on four classes of HILIC columns upon addition of 1-20 mM electrolyte. The effect of four electrolytes (NaCl, NaClO, NaPF, and NaCFCO) were tested on neutral, cationic, anionic, and zwitterionic analytes under HILIC conditions (70-90% ACN). These electrolytes alter the retention and selectivity on silica, zwitterionic and diol columns through ion exchange and ionic screening mechanisms.
View Article and Find Full Text PDFLinear solvation energy relationships (LSERs) were applied to retention on hypercrosslinked polystyrene on silica (HC-Tol) to elucidate the type and relative importance of molecular interactions between model solutes and the HC-Tol stationary phase. Classical amino phase and another hypercrosslinked phase (5-HGN) were used as reference columns. On both the HC-Tol and amino, polar interactions predominate and contribute to retention.
View Article and Find Full Text PDFJ Chromatogr A
September 2017
Coupling the modified Soczewiñski model and one gradient run, a gradient method was developed to build a linear solvation energy relationship (LSER) for normal phase chromatography. The gradient method was tested on dinitroanilinopropyl (DNAP) and silica columns with hexane/dichloromethane (DCM) mobile phases. LSER models built based on the gradient separation agree with those derived from a series of isocratic separations.
View Article and Find Full Text PDFThe two-tailed cationic surfactant dioctadecyldimethyl ammonium bromide (DODAB) produces semi-permanent coatings that yield strongly reversed electroosmotic flow (EOF), for example -0.31 ± 0.01 cm kV s at pH 3.
View Article and Find Full Text PDFThe Snyder model and the Soczewiñski model are compared on classic NPLC bonded phases using literature data, and on the charge transfer 2, 4-dinitroanilinopropyl (DNAP) column using experimentally collected data. Overall, the Snyder model slightly better predicts the n-slope than the Soczewiñski model. However, both models give comparable uncertainty in predicting n-slope for a given compound.
View Article and Find Full Text PDFThis work systematically investigates the selectivity changes on many HILIC phases from w(w)pH 3.7-6.8, at 5 and 25mM buffer concentrations.
View Article and Find Full Text PDFIn this study, the effect of column overload of the matrix ion, chloride, on the elution peak profiles of trace bromate is investigated. The resultant peak profiles of chloride and bromate are explained on the basis of competitive Langmuir isotherms. The Thermo IonPac AS9-HC, AS19 and AS23 columns are recommended by the manufacturer for bromate (a carcinogen) analysis.
View Article and Find Full Text PDFCharge-transfer and hypercrosslinked polystyrene phases offer retention and separation for polycyclic aromatic hydrocarbons (PAHs) and thus have potential for petroleum analysis. The size, shape and planarity selectivity for PAH standards on charge-transfer (DNAP column) and hypercrosslinked polystyrene (HC-Tol and 5HGN columns) phases are different under normal phase liquid chromatography (NPLC). The HC-Tol column behaves like a conventional NPLC column with low retention of PAHs.
View Article and Find Full Text PDFElectrospray ionization mass spectrometry (ESI-MS) has significantly impacted the analysis of complex biological and petroleum samples. However ESI-MS has limited ionization efficiency for samples in low dielectric and low polarity solvents. Addition of a make-up solvent through a T union or electrospray solvent through continuous flow extractive desorption electrospray ionization (CF-EDESI) enable ionization of analytes in non-ESI friendly solvents.
View Article and Find Full Text PDFPorous graphitic carbon (PGC) is an increasingly popular and attractive phase for HPLC on account of its chemical and thermal stability, and its unique separation mechanism. However, native PGC is strongly hydrophobic and in some instances excessively retentive. As part of our effort to build a library of hydrophilic covalently modified PGC phases, we functionalized PGC with catechol and amide groups by means of aryl diazonium chemistry to produce two new phases.
View Article and Find Full Text PDFMost stationary phases for hydrophilic interaction liquid chromatography (HILIC) and reversed phase liquid chromatography (RPLC) are based on silica. Porous graphitic carbon (PGC) is an attractive alternative to silica-based phases due to its chemical and thermal stability, and unique selectivity. However, native PGC is strongly hydrophobic and in some instances excessively retentive.
View Article and Find Full Text PDFIn HPLC, injection of solvents that differ from the eluent can result in peak broadening due to solvent strength mismatch or viscous fingering. Broadened, distorted or even split analyte peaks may result. Past studies of this injection-induced peak distortion in reversed phase (RPLC) and hydrophilic interaction (HILIC) liquid chromatography have led to the conclusion that the sample should be injected in the eluent or a weaker solvent.
View Article and Find Full Text PDFHypercrosslinked polystyrene phases have been described as quasi-normal phase because they lack discrete polar sites. Retention on the HC-Tol column is investigated using the Snyder-Soczewinski model. Solvent strength of different hexane-solvent binary mobile phase compositions can be predicted with solvent strength of pure dichloromethane (DCM, 0.
View Article and Find Full Text PDFPolycationic polymers are widely used in capillary electrophoresis (CE) as surface coatings to prevent protein adsorption and control electroosmotic flow (EOF). Such semi-permanent coatings are formed by flushing the capillary with a quaternary amine-based polymer such as poly(diallydimethylammonium chloride) (PDADMAC) or polybrene. Compared to covalent capillary coatings, the claimed advantages of adsorptive polycation coatings are their simple preparation and that they are not limited to the pH 2-8 range as are covalent coatings.
View Article and Find Full Text PDFHydrophilic interaction liquid chromatography (HILIC) is a fast growing separation technique for hydrophilic and polar analytes. In this work, we combine the unique selectivity of carbon surfaces with the high efficiency of core-shell silica. First, 5 μm core-shell silica is electrostatically coated with 105 nm cationic latex bearing quaternary ammonium groups.
View Article and Find Full Text PDFThe elution profile of chromatographic peaks provides fundamental understanding of the processes that occur in the mobile phase and the stationary phase. Major advances have been made in the column chemistry and suppressor technology in ion chromatography (IC) to handle a variety of sample matrices and ions. However, if the samples contain high concentrations of matrix ions, the overloaded peak elution profile is distorted.
View Article and Find Full Text PDFVoid volume is an important fundamental parameter in chromatography. Little prior discussion has focused on the determination of void volume in normal phase liquid chromatography (NPLC). Various methods to estimate the total void volume are compared: pycnometry; minor disturbance method based on injection of weak solvent; tracer pulse method; hold-up volume based on unretained compounds; and accessible volume based on Martin's rule and its descendants.
View Article and Find Full Text PDFStationary phases for hydrophilic interaction liquid chromatography (HILIC) are predominantly based on silica and polymer supports. We present porous graphitic carbon particles with covalently attached carboxylic acid groups (carboxylate-PGC) as a new HILIC stationary phase. PGC particles were modified by adsorbing the diazonium salt of 4-aminobenzoic acid onto the PGC, followed by reduction of the adsorbed salt with sodium borohydride.
View Article and Find Full Text PDFThe development of small particles in ion chromatography (IC) is a recent phenomenon. Very few studies are available on packing polymeric particles bearing ionizable functional groups. This study explores the colloidal and rheological properties that govern slurry packing to form high efficiency IC columns.
View Article and Find Full Text PDFBare silica monoliths do not possess anion exchange sites hence they show low retention for anions. Moreover, bare silica monoliths show low retention in hydrophilic interaction liquid chromatography (HILIC). Coating the silica surface with cationic nanoparticles e.
View Article and Find Full Text PDFThis paper uses the HILIC selectivity data of Dinh et al. (J. Chromatogr.
View Article and Find Full Text PDFA sequential surfactant bilayer/diblock copolymer coating was previously developed for the separation of proteins. The coating is formed by flushing the capillary with the cationic surfactant dioctadecyldimethylammonium bromide (DODAB) followed by the neutral polymer poly-oxyethylene (POE) stearate. Herein we show the method development and optimization for capillary isoelectric focusing (cIEF) separations based on the developed sequential coating.
View Article and Find Full Text PDF