Purpose: To evaluate the compressive stiffness (ability to resist compression under an applied load) of fragment-specific plate and headless screw fixation for radial styloid and volar lunate facet fractures in a synthetic composite distal radius.
Methods: A simulated radial styloid fracture (AO type B1.1) and simulated volar lunate facet fracture (AO type B3.
Biomed Phys Eng Express
June 2024
This study evaluated the feasibility of the femoral bone after fixation using biphasic calcium phosphate cement-augmentation of the proximal femoral nail antirotation (PFNA) compared with PFNA without cement. This study presented to compare the stiffness, fatigue testing, and compressive strength between stable (AO31-A2.1) and unstable (AO31-A3.
View Article and Find Full Text PDFThis study explores the comparative fatigue performance of decarburized surfaces in railway components, emphasizing rolling contact fatigue, crack propagation, and acoustic emission. The investigation entails the examination of two grades of railway steels, namely R260 and U71Mn, to analyze crack and surface characteristics subsequent to fatigue testing employing a Twin Roller Machine. The purpose is to discern the impact of decarburization on the fatigue life of these materials.
View Article and Find Full Text PDFDistal radius fractures (DRFs) are one of the most common fractures of the upper extremity system. To evaluate the performance of DRF treatments, the construct (i.e.
View Article and Find Full Text PDFVulcanized rubbers are commonly used to provide the energy absorption under compressive deformation from other engineering components. However, if a constant compressive deformation is maintained on rubber, the load response is not constant but decreases with time; i.e.
View Article and Find Full Text PDFFretting fatigue experiments and finite element analysis were carried out to investigate the influence of cylindrical-on-flat contact on crack nucleation, crack path and fatigue life of medium-carbon steel. The location of crack nucleation was predicted using the maximum shear stress range criterion and the maximum relative slip amplitude criterion. The prediction using the maximum relative slip amplitude criterion gave the better agreement with the experimental result, and should be used for the prediction of the location of crack nucleation.
View Article and Find Full Text PDFJ Appl Biomech
November 2012
A locking compression plate (LCP) can serve as an external fixation for fractured tibia. However, there is concern about the stability and endurance during partial weight bearing. This study was experimentally evaluated the effects of fracture gap sizes (1, 5, and 10 mm) on the stability and endurance of fractured tibia externally fixed with a 316L-stainless LCP.
View Article and Find Full Text PDFThe effects of locking screw position (long column fixation--long distance between the nearest screws to the fracture--and short column fixation--short distance between the nearest screws to the fracture) and fracture gap size (1-mm and 8-mm transverse fracture gap) on stiffness and fatigue of fractured femur fixed with a locking compression plate (LCP) were biomechanically evaluated. The stiffness of 1-mm fracture gap models and that of intact femoral model were in the range of 270-284 N/mm, while those of 8-mm fracture gap models were significantly lower (155-170 N/mm). After 1,000,000 cycles of loading, no fracture of LCP of 1-mm fracture gap models fixed in either long column or short column fashions occurred.