Publications by authors named "Changmin Ahn"

We demonstrate a self-homodyne detection method to stabilize a continuous-wave 1550-nm laser to a 1-km optical fiber delay line, achieving a frequency instability of 6.3 × 10 at a 16-ms averaging time. This result, limited by fiber thermal noise, is achieved without the need for a vacuum system, highlighting the potential of our approach for ultra-stable laser systems in non-laboratory environments.

View Article and Find Full Text PDF

Pulse repetition rate multiplier (PRRM) is an essential component of microwave photonics systems, designed not only to alleviate photodiode saturation but also to provide more frequent pulses. However, the presence of interleaving time errors is known to compromise the advantages of PRRM. In this study, we present a high-sensitivity detection method for identifying these time errors using an electro-optic sampling-based timing detector (EOS-TD).

View Article and Find Full Text PDF

High-speed and high-resolution imaging of surface profiles is critical for the investigation of various structures and mechanical dynamics of micro- and nano-scale devices. In particular, recent emergence of various nonlinear, transient and complex mechanical dynamics, such as anharmonic vibrations in mechanical resonators, has necessitated real-time surface deformation imaging with higher axial and lateral resolutions, speed, and dynamic range. However, real-time capturing of fast and complex mechanical dynamics has been challenging, and direct time-domain imaging of displacements and mechanical motions has been a missing element in studying full-field structural and dynamic behaviours.

View Article and Find Full Text PDF

There has been remarkable progress in generating ultralow-noise microwaves from optical frequency combs in the last decade. While a combination of techniques has enabled tens to hundreds of attoseconds residual jitter in microwave extraction, so far most of research efforts have been focused on extracting single-tone microwaves from combs; there has been no study on the noise properties of photocurrent pulses directly extracted from the photodiode. Here, we reveal that the residual jitter between optical pulses and rising edges of photocurrent pulses can be in the tens of attoseconds regime.

View Article and Find Full Text PDF

Methane in a simulated biogas converting to methanol under aerobic condition was comparatively assessed by inhibiting the activity of methanol dehydrogenase (MDH) of Methylosinus sporium using phosphate, NaCl, NH4Cl or EDTA in their varying concentrations. The highest amount of methane was indistinguishably diverted at the typical conditions regardless of the types of inhibitors: 35°C and pH 7 under a 0.4% (v/v) of biogas, specifically for <40 mM phosphate, 50 mM NaCl, 40 mM NH4Cl or 150 µM EDTA.

View Article and Find Full Text PDF

Using a methanotrophic consortium (that includes Methylosinus sporium NCIMB 11126, Methylosinus trichosporium OB3b, and Methylococcus capsulatus Bath) isolated from a landfill site, the potential for partial oxidation of methane into methanol through selective inhibition of methanol dehydrogenase (MDH) over soluble methane monooxygenase (sMMO) with some selected MDH inhibitors at varied concentration range, was evaluated in batch serum bottle and bioreactor experiments. Our result suggests that MDH activity could effectively be inhibited either at 40 mM of phosphate, 100 mM of NaCl, 40 mM of NH4Cl or 50 μM of EDTA with conversion ratios (moles of CH3OH produced per mole CH4 consumed) of 58, 80, 80, and 43 %, respectively. The difference between extent of inhibition in MDH activity and sMMO activity was significantly correlated (n = 6, p < 0.

View Article and Find Full Text PDF

1,4-Dioxane is one of the by-products from the polyester manufacturing process, which has been carelessly discharged into water bodies and is a weak human carcinogen. In this study, a laboratory-scale, up-flow biological aerated filter (UBAF), packed with tire chips, was investigated for the treatment of 1,4-dioxane. The UBAF was fed with effluent, containing an average of 31 mg/L of 1,4-dioxane, discharged from an anaerobic treatment unit at H Co.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_session0rei97qdp7l1akbqccf17paaehd52nv6): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once