Case: We present a unique case of a 45-year-old man with his right middle finger embedded with rings. Limited finger flexion was noted because of flexor tendon injury caused by the dorsal migration of the embedded ring through joint. The rings were removed under anesthesia, resulting in the resolution of swelling and recover of osseous structure.
View Article and Find Full Text PDFBackground: The inclusion of a connecting path in a porous implant can promote nutrient diffusion to cells and enhance bone ingrowth. Consequently, this study aimed to evaluate the biomechanical, radiographic, and histopathological performance of a novel 3D-printed porous suture anchor in a rabbit femur model.
Methods: Three test groups were formed based on the type of suture anchor (SA): Commercial SA (CSA, Group A, n = 20), custom solid SA (CSSA, Group B, n = 20), and custom porous SA (CPSA, Group C, n = 20).
Background: Colorectal cancer is one of the most frequently diagnosed forms of cancer, and it is associated with several common symptoms and signs such as rectal bleeding, altered bowel habits, abdominal pain, anemia, and unintentional weight loss. Sciatica, a debilitating condition in which the patient experiences paresthesia and pain in the dermatome of associated lumbosacral nerve roots or sciatic nerve distribution, is not considered one of these. Here we present a case of colorectal cancer manifesting symptoms of sciatica alone.
View Article and Find Full Text PDFBackground: Acute kidney injury (AKI) is a severe postoperative complication associated with poor clinical outcomes, including the development of chronic kidney disease (CKD) and death. This study aimed to investigate the incidence and determinants of AKI following elective surgeries for degenerative lumbar spine disease.
Methods: All patient data were extracted from the US Nationwide Inpatient Sample database.
A medial meniscus posterior root tear (MMPRT) contributes to knee joint degeneration. Arthroscopic transtibial pullout repair (ATPR) may restore biomechanical integrity for load transmission. However, degeneration persists after ATPR in certain patients, particularly those with preoperative subchondral insufficiency fracture of the knee (SIFK).
View Article and Find Full Text PDFBackground: Surgeons are routinely required to remove loose or failed pedicle screws and insert a new screw in their place. However, inserting a new screw into an existing hole may compromise the holding capacity of the pedicle screw. The purpose of this study is to evaluate the pullout strength of pedicle screws with different thread designs after the primary insertion and revision surgery in a synthetic bone model.
View Article and Find Full Text PDFIntroduction: We aimed to investigate the prognostic determinants of life-threatening and fatal complications in patients <80 and ≥ 20 years of age and those ≥80 years who were undergoing surgery for spinal metastases.
Materials And Methods: Based on data between 2005 and 2018 extracted from National Inpatient Sample as the largest longitudinal hospital inpatient databases in the United States, statistical analyses were performed to identify prognostic factors (age, sex, household income, insurance status, major comorbidities, primary site of malignancy, types of surgery, surgical approaches, types of hospital admission, and hospital-related characteristics) for major and fatal perioperative complications among older adult patients.
Results: A total of 31,925 patients aged ≥ 20y who were undergoing surgery for spinal metastasis were identified (< 80 y: n = 28,448; ≥ 80 y: n = 35,37).
Pullout strength is an important indicator of the performance and longevity of pedicle screws and can be heavily influenced by the screw design, the insertion technique and the quality of surrounding bone. The purpose of this study was to investigate the pullout strength of three different pedicle screws inserted using three different strategies and with two different loading conditions. Three pedicle screws with different thread designs (single-lead-thread (SLT) screw, dual-lead-thread (DLT) screw and mixed-single-lead-thread (MSLT) screw) were inserted into a pre-drilled rigid polyurethane foam block using three strategies: (A) screw inserted to a depth of 33.
View Article and Find Full Text PDFBackground: We assessed the efficacy of a novel platelet-rich fibrin (PRF)-augmented repair strategy for promoting biological healing of an anterior cruciate ligament (ACL) midsubstance tear in a rabbit model. The biological gap-bridging effect of a PRF scaffold alone or in combination with rabbit ligamentocytes on primary ACL healing was evaluated both in vitro and in vivo.
Hypothesis: A PRF matrix can be implanted as a provisional fibrin-platelet bridging scaffold at an ACL defect to facilitate functional healing.
Background and Objectives: Using an appropriate torque to tighten set screws ensures the long-term stability of spinal posterior fixation devices. However, the recommended torque often varies between different devices and some devices do not state a recommended torque level. The purpose of this study is to evaluate the effect of set screw torque on the overall construct stability and fatigue life.
View Article and Find Full Text PDFBackground: Lumbar spinal fusion with rigid spinal fixators as one of the high risk factors related to adjacent-segment failure. The purpose of this study is to investigate how the material properties of spinal fixation rods influence the biomechanical behavior at the instrumented and adjacent levels through the use of the finite element method.
Methods: Five finite element models were constructed in our study to simulate the human spine pre- and post-surgery.
Pedicle screws are commonly used for posterior stabilization of the spine. When used in deformed or degenerated segments, the pedicle screws are often not fully inserted into the bone, but instead the threaded portion is exposed by 1 or 2 threads to accommodate rod placement and ensure alignment between the tulip of the screw and the rod. However, broken pedicle screws have been reported with the use of this method.
View Article and Find Full Text PDFBackground: Effective treatment of low back pain (LBP) originating in the lumbar and sacroiliac joints is difficult to achieve. The objective of the current study was to compare the clinical effectiveness of radiofrequency (RF) neurotomy versus conservative nonsurgical approaches for the management of chronic lumbar and sacroiliac joint pain.
Methods: The PICOS framework was adhered to (P [population]: patients with a history of chronic function-limiting lumbar and sacroiliac joint pain lasting at least 6 months; I [intervention]: RF neurotomy; C [comparator]: other nonsurgical treatments; O [outcomes]: the Oswestry Disability Index (ODI), measurement for pain, and a quality of life (QoL) questionnaire; S [study design]: meta-analysis).
The majority of compressive vertebral fractures in osteoporotic bone occur at the level of the thoracolumbar junction. Immediate decompression is often required in order to reduce the extent of neurological damage. This study evaluated four fixation methods for decompression in patients with thoracolumbar burst fractures, and presented the most suitable method for osteoporotic patients.
View Article and Find Full Text PDFBackground And Objectives: This study is a meta-analysis of randomized controlled trials comparing the efficacy of transcutaneous electrical nerve stimulation (TENS) to a control and to other nerve stimulation therapies (NSTs) for the treatment of chronic back pain.
Methods: Citations were identified in MEDLINE, the Cochrane Library, Google Scholar, and ClinicalTrials.gov through June 2014 using the following keywords: nerve stimulation therapy, transcutaneous electrical nerve stimulation, back pain, chronic pain.
Interbody fusion with posterior instrumentation is a common method for treating lumbar degenerative disc diseases. However, the high rigidity of the fusion construct may produce abnormal stresses at the adjacent segment and lead to adjacent segment degeneration (ASD). As such, biodegradable implants are becoming more popular for use in orthopaedic surgery.
View Article and Find Full Text PDFBackground Context: Minimally invasive spine surgery has become increasingly popular in clinical practice, and it offers patients the potential benefits of reduced blood loss, wound pain, and infection risk, and it also diminishes the loss of working time and length of hospital stay. However, surgeons require more intraoperative fluoroscopy and ionizing radiation exposure during minimally invasive spine surgery for localization, especially for guidance in instrumentation placement. In addition, computer navigation is not accessible in some facility-limited institutions.
View Article and Find Full Text PDFRecent advances in tissue engineering have led to potential new strategies, especially decellularization protocols from natural tissues, for the repair, replacement, and regeneration of intervertebral discs. This study aimed to validate our previously reported method for the decellularization of annulus fibrosus (AF) tissue and to quantify potentially antigenic α-Gal epitopes in the decellularized tissue. Porcine AF tissue was decellularized using different freeze-thaw temperatures, chemical detergents, and incubation times in order to determine the optimal method for cell removal.
View Article and Find Full Text PDFBackground Data: Combined usage of posterior lumbar interbody fusion and transpedicular fixation has been extensively used to treat the various lumbar degenerative disc diseases. The transpedicular fixator aims to increase stability and enhance the fusion rate. However, how the fused disc and bridged vertebrae respectively affect adjacent-segment diseases progression is not yet clear.
View Article and Find Full Text PDFBackground: Failure of pedicle screw is a major concern in spinal surgery. The threaded and unthreaded portions of the pedicle screw provide the ability to anchor and squeeze the surrounding bone, respectively. This study aimed to investigate the anchoring and squeezing effects of different design of the threaded/unthreaded portions of a pedicle screw to vertebrae.
View Article and Find Full Text PDFHonokiol is a potential candidate for the treatment of intervertebral disc (IVD) degeneration. In this study, we develop in vitro and in vivo methods to detect the distribution of honokiol in intervertebral discs using high-performance liquid chromatography. A rat tail disc was used for both experimental models.
View Article and Find Full Text PDFPurpose: The purpose was to quantify the structural integrity of annulus fibrosis (AF) after injuries with repair.
Methods: Punctures in the AF of 6-month-old porcine spine specimens were made with 18-, 20-, 22-, 24-, and 26-gauge needles. Leakage testing was performed immediately after needle puncture (Group 1), after the puncture was repaired with a modified purse-string suture (MPSS) (Group 2), and after needle puncture with immediate repair (Group 3).