Despite remarkable progress in DNA sequencing technologies there remains a trade-off between short-read platforms, having limited ability to sequence homopolymers, repeated motifs or long-range structural variation, and long-read platforms, which tend to have lower accuracy and/or throughput. Moreover, current methods do not allow direct readout of epigenetic modifications from a single read. With the aim of addressing these limitations, we have developed an optical electrowetting sequencing platform that uses step-wise nucleotide triphosphate (dNTP) release, capture and detection in microdroplets from single DNA molecules.
View Article and Find Full Text PDFA new approach to single-molecule DNA sequencing in which dNTPs, released by pyrophosphorolysis from the strand to be sequenced, are captured in microdroplets and read directly could have substantial advantages over current sequence-by-synthesis methods; however, there is no existing method sensitive enough to detect a single nucleotide in a microdroplet. We have developed a method for dNTP detection based on an enzymatic two-stage reaction which produces a robust fluorescent signal that is easy to detect and process. By taking advantage of the inherent specificity of DNA polymerases and ligases, coupled with volume restriction in microdroplets, this method allows us to simultaneously detect the presence of and distinguish between, the four natural dNTPs at the single-molecule level, with negligible cross-talk.
View Article and Find Full Text PDFBackground: The deep inferior epigastric perforator (DIEP) flap is widely regarded as the Gold Standard in autologous breast reconstruction. Although drain-free abdominoplasty is performed in many centres, there is a paucity of evidence comparing outcomes when applied to DIEP breast reconstruction.
Method: A retrospective review of patients who underwent DIEP breast reconstruction without abdominal drain insertion at Royal Free Hospital between Jan 2012-Nov 2016 was undertaken.
We explore phase transitions of polariton wave packets, first, to a soliton and then to a standing wave polariton condensate in a multimode microwire system, mediated by nonlinear polariton interactions. At low excitation density, we observe ballistic propagation of the multimode polariton wave packets arising from the interference between different transverse modes. With increasing excitation density, the wave packets transform into single-mode bright solitons due to effects of both intermodal and intramodal polariton-polariton scattering.
View Article and Find Full Text PDFCertain xenobiotics, such as paraquat, are sequestered into the lungs from the systemic circulation by the polyamine transporter system (PTS). The aim of this study was to investigate whether ion-pairing a drug (theophylline) with a PTS substrate (spermine) provides a means of using this active transport mechanism to target drug delivery to the lungs. Fourier transform infrared spectroscopy showed that two of the amine groups of spermine interact with C-N and C═O of theophylline, leaving two free amines to interact with the PTS.
View Article and Find Full Text PDFExciton-polaritons in semiconductor microcavities form a highly nonlinear platform to study a variety of effects interfacing optical, condensed matter, quantum and statistical physics. We show that the complex polariton patterns generated by picosecond pulses in microcavity wire waveguides can be understood as the Cherenkov radiation emitted by bright polariton solitons, which is enabled by the unique microcavity polariton dispersion, which has momentum intervals with positive and negative group velocities. Unlike in optical fibres and semiconductor waveguides, we observe that the microcavity wire Cherenkov radiation is predominantly emitted with negative group velocity and therefore propagates backwards relative to the propagation direction of the emitting soliton.
View Article and Find Full Text PDFBackground: Patients make a crucial contribution to undergraduate medical education. Although a national resource is available for patients participating in research, none is as yet available for education.
Aim: This study aimed to explore what information patients would like about participation in general practice based undergraduate medical education, and how they would like to obtain this information.
Many chemotherapeutics suffer from poor aqueous solubility and tissue selectivity. Distearoylphosphatidylethanolamine-poly(ethylene glycol) (DSPE-PEG) micelles are a promising formulation strategy for the delivery of hydrophobic anticancer drugs. However, storage and in vivo instability restrict their use.
View Article and Find Full Text PDFThe Poly Implant Prosthèse™ (PIP) implants were withdrawn from market use in the United Kingdom on 31st March 2010 following Government issued advice. In June 2012 a final Government report was issued and during this period the majority of patients elected to have their prostheses removed. This study presents the operative findings of three surgeons.
View Article and Find Full Text PDFPhys Rev Lett
December 2015
We report propagating bound microcavity polariton soliton arrays consisting of multipeak structures either along (x) or perpendicular (y) to the direction of propagation. Soliton arrays of up to five solitons are observed, with the number of solitons controlled by the size and power of the triggering laser pulse. The breakup along the x direction occurs when the effective area of the trigger pulse exceeds the characteristic soliton size determined by polariton-polariton interactions.
View Article and Find Full Text PDFUnlabelled: Fracture Liaison Services are the best model to prevent secondary fractures. The International Osteoporosis Foundation developed a Best Practice Framework to provide a quality benchmark. After a year of implementation, we confirmed that a single framework with set criteria is able to benchmark services across healthcare systems worldwide.
View Article and Find Full Text PDFJ Plast Reconstr Aesthet Surg
June 2015
Introduction: We recently published data for the duration of donor site drain use in latissimus dorsi and deep inferior epigastric perforator breast reconstruction, due to a reported requirement in the literature; evidence is still required for transverse rectus abdominis myocutaneous (TRAM) reconstruction.
Aim: To compare inpatient hospital stay, drainage parameters and donor-site complications associated with closed suction abdominal drain removal by post-operative day (POD) 3 regardless of output (early group), versus after POD 3 where instructions were by drainage volume/24 h ± output consistency (late group), in post-mastectomy TRAM breast reconstruction.
Method: A retrospective review of TRAM breast reconstructions, between June 2008-2013, was undertaken with a minimum 1 year follow-up per patient.
J Plast Reconstr Aesthet Surg
February 2015
This study demonstrated the feasibility of trigger-responsive inhaled delivery of medicines using soft solid shelled nanocapsules. The delivery system was a 50nm sized lipid rich capsule carrier that distended rapidly when mixed with an exogenous non-ionic surfactant trigger, Pluronic® L62D. Capsule distension was accompanied by solid shell permeabilisation which resulted in payload release from the carrier; 63.
View Article and Find Full Text PDFSummary: There is variation in how services to prevent second fractures after hip fracture are organised. We explored this in more detail at 11 hospitals. Results showed that there was unwarranted variation across a number of aspects of care.
View Article and Find Full Text PDFHip fractures represent the most severe complication of osteoporosis from the perspectives of the patient, carer, health care system and society. Given the strong association with age, numbers are set to rise significantly in the next few decades despite evidence that the age adjusted rates in some countries are either plateauing or falling. Given the almost invariable need for inpatient admission, hospital administrative data for hip fractures remain a robust measure of number of hip fractures in the community and can be extrapolated to determine the total expected number of clinical fragility fractures from the same population.
View Article and Find Full Text PDFJ Plast Reconstr Aesthet Surg
July 2014
Introduction: The deep inferior epigastric perforator (DIEP) flap is often preferred for breast reconstruction as it allows for autologous reconstruction with less donor site morbidity versus transverse rectus abdominis myocutaneous (TRAM) flap reconstruction. Our group has presented and published data for the duration of donor site back drain use in latissimus dorsi (LD) flap breast reconstruction due to insufficient evidence and a requirement for further investigation in the literature; this evidence is still lacking for DIEP reconstruction.
Aim: To compare inpatient hospital stay, drainage parameters and donor-site complications associated with closed suction abdominal drain removal by post-operative day (POD) 3 regardless of output (early group), with removal after POD 3 where instructions were by drainage volume/24 h±output consistency (late group), in post-mastectomy DIEP reconstruction donor sites.
We report on the spin properties of bright polariton solitons supported by an external pump to compensate losses. We observe robust circularly polarized solitons when a circularly polarized pump is applied, a result attributed to phase synchronization between nondegenerate TE and TM polarized polariton modes at high momenta. For the case of a linearly polarized pump, either σ+ or σ- circularly polarized bright solitons can be switched on in a controlled way by a σ+ or σ- writing beam, respectively.
View Article and Find Full Text PDFJ Plast Reconstr Aesthet Surg
February 2014
Introduction: The pedicled latissimus dorsi myocutaneous (LD) flap is a popular breast reconstruction choice, representing approximately 50% of procedures undertaken in the UK. Donor site drain use may reduce complication rates, however no evidence exists regarding the duration of back drain use for LD flap breast reconstruction and calls have been made in the literature to investigate this further.
Aim: To compare inpatient hospital stay, drainage parameters and donor-site complications associated with closed suction back drain removal by post-operative day (POD) 3 regardless of output (early group), with removal after POD 3 where instructions were documented by drainage volume/24 h ± output consistency (late group), in post-mastectomy LD reconstruction donor sites.
J Plast Reconstr Aesthet Surg
July 2013
The latissimus dorsi flap, first performed by Tansini in 1892, was popularised for use by Olivari in 1976. The successful transfer of a latissimus dorsi flap during breast reconstruction has previously been thought to be dependent on having an intact thoracodorsal pedicle to ensure flap survival. It is well documented that the flap may also survive on the serratus branch in thoracodorsal pedicle division.
View Article and Find Full Text PDFA 67-year-old man presented to the acute medical take with a history of droopy eyelids and difficulty swallowing. A diagnosis of myasthenia gravis was suspected from the clinical history. The patient's symptoms were progressive, raising concerns of aspiration pneumonia or respiratory compromise if untreated.
View Article and Find Full Text PDFWorldwide, approximately 405 000 cases of oral cancer (OSCC) are diagnosed each year, with a rising incidence in many countries. Despite advances in surgery and radiotherapy, which remain the standard treatment options, the mortality rate has remained largely unchanged for decades, with a 5-year survival rate of around 50%. OSCC is a heterogeneous disease, staged currently using the TNM classification, supplemented with pathological information from the primary tumour and loco-regional lymph nodes.
View Article and Find Full Text PDFFree tissue transfer has revolutionized the management of complex head and neck defects. Perforator flaps represent the most recent advance in the development of free flap surgery. These flaps are based on perforating vessels and can be harvested without significant damage to associated muscles, thereby reducing the postoperative morbidity associated with muscle-based flaps.
View Article and Find Full Text PDF