Publications by authors named "Chad Roller"

A high-resolution liquid-nitrogen-free mid-infrared tunable diode laser absorption spectroscopy (TDLAS) system was used to perform real-time measurement of acetaldehyde concentrations in human exhaled breath following ingestion of an alcoholic beverage. Acetaldehyde absorption features were measured near 5.79 mum (1727 cm(-1)) using a IV-VI semiconductor laser, a 100 m long path optical gas cell, and second- harmonic detection coupled with wavelength modulation.

View Article and Find Full Text PDF

Recent developments of two mid-infrared tunable laser spectrometers dedicated to carbon isotope ratio determination are presented. First, a field deployable quantum cascade laser-based sensor is described, along with line selection strategy for (13/12)CO(2) ratio measurements. Secondly, an instrument architecture based on difference frequency generation is presented.

View Article and Find Full Text PDF

Simultaneous exhaled carbonyl sulfide (OCS) and carbon dioxide concentration measurements in human breath are demonstrated with a compact pulsed quantum-cascade laser-based gas sensor. We achieved a noise-equivalent sensitivity (1sigma) of 1.2 parts per billion by measuring a well-isolated OCS P(11) absorption line in the v3 band at 2057.

View Article and Find Full Text PDF

We report on the development and performance of a gas sensor based on a quantum cascade laser operating at a wavelength of approximately 10 microns to measure ethylene (C2H4) concentrations by use of a rotational component of the fundamental nu 7 band. The laser is thermoelectrically cooled and operates in a pulsed mode. The influence of pulse-to-pulse fluctuations is minimized by use of a reference beam and a single detector with time discriminating electronics.

View Article and Find Full Text PDF

Tunable-laser absorption spectroscopy in the mid-IR spectral region is a sensitive analytical technique for trace-gas quantification. The detection of nitric oxide (NO) in exhaled breath is of particular interest in the diagnosis of lower-airway inflammation associated with a number of lung diseases and illnesses. A gas analyzer based on a continuous-wave mid-IR quantum cascade laser operating at approximately 5.

View Article and Find Full Text PDF

A compact absorption spectrometer with a midinfrared tunable quantum cascade laser operating at 4.86 microm (2054 cm(-1)) is used to measure lower concentrations of carbonyl sulfide (COS) in air. A detection sensitivity of approximately 30 parts in 10(9) of COS and the selectivity of two stable isotopes, 12C(16)O32S and 12C(16)O34S, are demonstrated.

View Article and Find Full Text PDF

We used a high-resolution mid-IR tunable-laser absorption spectroscopy (TLAS) system with a single IV-VI laser operating near 5.2 microm to measure the level of exhaled nitric oxide (eNO) in human breath. A method of internal calibration using simultaneous eNO and exhaled CO2 measurements eliminated the need for system calibration with gas standards.

View Article and Find Full Text PDF