We present the measurements of individual bound electron g factors of ^{20}Ne^{9+} and ^{22}Ne^{9+} on the relative level of 0.1 parts per billion. The comparison with theory represents the most stringent test of bound-state QED in strong electric fields.
View Article and Find Full Text PDFPhys Rev Lett
December 2023
Isomers close to doubly magic _{28}^{78}Ni_{50} provide essential information on the shell evolution and shape coexistence near the Z=28 and N=50 double shell closure. We report the excitation energy measurement of the 1/2^{+} isomer in _{30}^{79}Zn_{49} through independent high-precision mass measurements with the JYFLTRAP double Penning trap and with the ISOLTRAP multi-reflection time-of-flight mass spectrometer. We unambiguously place the 1/2^{+} isomer at 942(10) keV, slightly below the 5/2^{+} state at 983(3) keV.
View Article and Find Full Text PDFThe cyclotron frequency ratio of ^{187}Os^{29+} to ^{187}Re^{29+} ions was measured with the Penning-trap mass spectrometer PENTATRAP. The achieved result of R=1.000 000 013 882(5) is to date the most precise such measurement performed on ions.
View Article and Find Full Text PDFFirst ever measurements of the ratios of free cyclotron frequencies of heavy, highly charged ions with Z>50 with relative uncertainties close to 10^{-11} are presented. Such accurate measurements have become realistic due to the construction of the novel cryogenic multi-Penning-trap mass spectrometer PENTATRAP. Based on the measured frequency ratios, the mass differences of five pairs of stable xenon isotopes, ranging from ^{126}Xe to ^{134}Xe, have been determined.
View Article and Find Full Text PDFThis paper reports on the development and testing of a novel, highly efficient technique for the injection of very rare species into electron beam ion traps (EBITs) for the production of highly charged ions (HCI). It relies on in-trap laser-induced desorption of atoms from a sample brought very close to the electron beam resulting in a very high capture efficiency in the EBIT. We have demonstrated a steady production of HCI of the stable isotope Ho from samples of only 10 atoms (∼300 pg) in charge states up to 45+.
View Article and Find Full Text PDFElectron beam ion traps (EBITs) are ideal tools for both production and study of highly charged ions (HCIs). In order to reduce their construction, maintenance, and operation costs, we have developed a novel, compact, room-temperature design, the Heidelberg Compact EBIT (HC-EBIT). Four already commissioned devices operate at the strongest fields (up to 0.
View Article and Find Full Text PDF