Phys Chem Chem Phys
August 2024
Machine learning can reveal new insights into X-ray spectroscopy of liquids when the local atomistic environment is presented to the model in a suitable way. Many unique structural descriptor families have been developed for this purpose. We benchmark the performance of six different descriptor families using a computational data set of 24 200 sulfur Kβ X-ray emission spectra of aqueous sulfuric acid simulated at six different concentrations.
View Article and Find Full Text PDFJ Phys Chem Lett
February 2023
The hard X-ray Kβ″ emission line shows sensitivity with respect to a wide range of cation-ligand coordination, which we investigate in the cases of GeO and TiO on the basis of ab initio spectral calculations on amorphous and crystalline structures. In compressed amorphous GeO, the sampling of a large number of instantaneous coordination polyhedra from an ab initio molecular dynamics trajectory reveals that the functional relation between the Kβ″ shift and coordination is close to linear between 4-fold and 7-fold coordination. A similar sensitivity of the Kβ″ emission line exists in the coordination range between six and nine of crystalline high-pressure TiO polymorphs.
View Article and Find Full Text PDFA compact spectrometer for medium-resolution resonant and non-resonant X-ray emission spectroscopy in von Hámos geometry is described. The main motivation for the design and construction of the spectrometer is to allow for acquisition of non-resonant X-ray emission spectra while measuring non-resonant X-ray Raman scattering spectra at beamline ID20 of the European Synchrotron Radiation Facility. Technical details are provided and the performance and possible use of the spectrometer are demonstrated by presenting results of several X-ray spectroscopic methods on various compounds.
View Article and Find Full Text PDFNonlinear interactions between X-rays and long wavelength radiation can be used as a powerful atomic-scale probe for light-matter interactions and for properties of valence electrons. However, reported X-ray nonlinear effects were small and their observations required tremendous efforts. Here we report the observation of strong nonlinearities in parametric down-conversion (PDC) of X-rays to long wavelength radiation in gallium arsenide and lithium niobate crystals, with efficiencies about 4 orders of magnitude stronger than the efficiencies measured in any material studied before.
View Article and Find Full Text PDFAn end-station for resonant inelastic X-ray scattering and (resonant) X-ray emission spectroscopy at beamline ID20 of ESRF - The European Synchrotron is presented. The spectrometer hosts five crystal analysers in Rowland geometry for large solid angle collection and is mounted on a rotatable arm for scattering in both the horizontal and vertical planes. The spectrometer is optimized for high-energy-resolution applications, including partial fluorescence yield or high-energy-resolution fluorescence detected X-ray absorption spectroscopy and the study of elementary electronic excitations in solids.
View Article and Find Full Text PDFAn end-station for X-ray Raman scattering spectroscopy at beamline ID20 of the European Synchrotron Radiation Facility is described. This end-station is dedicated to the study of shallow core electronic excitations using non-resonant inelastic X-ray scattering. The spectrometer has 72 spherically bent analyzer crystals arranged in six modular groups of 12 analyzer crystals each for a combined maximum flexibility and large solid angle of detection.
View Article and Find Full Text PDFJ Synchrotron Radiat
March 2017
An algorithm to simultaneously increase the spatial and statistical accuracy of X-ray Raman scattering (XRS) based tomographic images is presented. Tomography that utilizes XRS spectroscopy signals as a contrast for the images is a new and promising tool for investigating local atomic structure and chemistry in heterogeneous samples. The algorithm enables the spatial resolution to be increased based on a deconvolution of the optical response function of the spectrometer and, most importantly, it allows for the combination of data collected from multiple analyzers and thus enhances the statistical accuracy of the measured images.
View Article and Find Full Text PDFJ Synchrotron Radiat
January 2017
A method to separate the non-resonant inelastic X-ray scattering signal of a micro-metric sample contained inside a diamond anvil cell (DAC) from the signal originating from the high-pressure sample environment is described. Especially for high-pressure experiments, the parasitic signal originating from the diamond anvils, the gasket and/or the pressure medium can easily obscure the sample signal or even render the experiment impossible. Another severe complication for high-pressure non-resonant inelastic X-ray measurements, such as X-ray Raman scattering spectroscopy, can be the proximity of the desired sample edge energy to an absorption edge energy of elements constituting the DAC.
View Article and Find Full Text PDFJ Synchrotron Radiat
November 2015
A closed-circle miniature flow cell for high X-ray photon flux experiments on radiation-sensitive liquid samples is presented. The compact cell is made from highly inert material and the flow is induced by a rotating magnetic stir bar, which acts as a centrifugal pump inside the cell. The cell is ideal for radiation-sensitive yet precious or hazardous liquid samples, such as concentrated acids or bases.
View Article and Find Full Text PDFJ Synchrotron Radiat
March 2015
A compilation of procedures for planning and performing X-ray Raman scattering (XRS) experiments and analyzing data obtained from them is presented. In particular, it is demonstrated how to predict the overall shape of the spectra, estimate detection limits for dilute samples, and how to normalize the recorded spectra to absolute units. In addition, methods for processing data from multiple-crystal XRS spectrometers with imaging capability are presented, including a super-resolution method that can be used for direct tomography using XRS spectra as the contrast.
View Article and Find Full Text PDFTemperature induced changes of the local chemical structure of bulk amorphous GexSiOy are studied by Ge K-edge x-ray absorption near-edge spectroscopy and Si L2/3-edge x-ray Raman scattering spectroscopy. Different processes are revealed which lead to formation of Ge regions embedded in a Si oxide matrix due to different initial structures of as-prepared samples, depending on their Ge/Si/O ratio and temperature treatment, eventually resulting in the occurrence of nanocrystals. Here, disproportionation of GeOx and SiOx regions and/or reduction of Ge oxides by pure Si or by a surrounding Si sub-oxide matrix can be employed to tune the size of Ge nanocrystals along with the chemical composition of the embedding matrix.