Differences in mean-square nuclear charge radii of ^{100-130}Cd are extracted from high-resolution collinear laser spectroscopy of the 5s ^{2}S_{1/2}→5p ^{2}P_{3/2} transition of the ion and from the 5s5p ^{3}P_{2}→5s6s ^{3}S_{1} transition in atomic Cd. The radii show a smooth parabolic behavior on top of a linear trend and a regular odd-even staggering across the almost complete sdgh shell. They serve as a first test for a recently established new Fayans functional and show a remarkably good agreement in the trend as well as in the total nuclear charge radius.
View Article and Find Full Text PDFIsomer shifts have been determined in ^{111-129}Cd by high-resolution laser spectroscopy at CERN-ISOLDE. The corresponding mean square charge-radii changes, from the 1/2^{+} and the 3/2^{+} ground states to the 11/2^{-} isomers, have been found to follow a distinct parabolic dependence as a function of the atomic mass number. Since the isomers have been previously associated with simplicity due to the linear mass dependence of their quadrupole moments, the regularity of the isomer shifts suggests a higher order of symmetry affecting the ground states in addition.
View Article and Find Full Text PDFThe neutron-rich isotopes of cadmium up to the N=82 shell closure have been investigated by high-resolution laser spectroscopy. Deep-uv excitation at 214.5 nm and radioactive-beam bunching provided the required experimental sensitivity.
View Article and Find Full Text PDFThe nuclear charge radius of (12)Be was precisely determined using the technique of collinear laser spectroscopy on the 2s(1/2)→2p(1/2,3/2) transition in the Be(+) ion. The mean square charge radius increases from (10)Be to (12)Be by δ
Charge radii of all magnesium isotopes in the sd shell have been measured, revealing evolution of the nuclear shape throughout two prominent regions of assumed deformation centered on (24)Mg and (32)Mg. A striking correspondence is found between the nuclear charge radius and the neutron shell structure. The importance of cluster configurations towards N=8 and collectivity near N=20 is discussed in the framework of the fermionic molecular dynamics model.
View Article and Find Full Text PDFThe time spreads of Mn ions produced by three-photon resonant ionization in a hot-cavity laser ion source are measured. A one-dimensional ion-transport model is developed to simulate the observed ion time structures. Assuming ions are generated with a Maxwellian velocity distribution and are guided by an axial electric field, the predictions of the model agree reasonably well with the experimental data and suggest that the ions are radially confined in the ion source and a substantial fraction of the ions in the transport tube are extracted.
View Article and Find Full Text PDFWe report the first confirmation of the predicted inversion between the pi2p3/2 and pi1f5/2 nuclear states in the nu(g)9/2 midshell. This was achieved at the ISOLDE facility, by using a combination of in-source laser spectroscopy and collinear laser spectroscopy on the ground states of 71,73,75Cu, which measured the nuclear spin and magnetic moments. The obtained values are mu(71Cu)=+2.
View Article and Find Full Text PDFThe first investigation of the transverse emittance of a hot-cavity laser ion source based on all-solid-state Ti:sapphire lasers is presented. The emittances of (63)Cu ion beams generated by three-photon resonant ionization are measured and compared with that of the (69)Ga and (39)K ion beams resulting from surface ionization in the same ion source. A self-consistent unbiased elliptical exclusion method is adapted for noise reduction and emittance analysis.
View Article and Find Full Text PDFNuclear charge radii of ;{7,9,10,11}Be have been determined by high-precision laser spectroscopy. On-line measurements were performed with collinear laser spectroscopy in the 2s_{1/2}-->2p_{1/2} transition on a beam of Be+ ions. Collinear and anticollinear laser beams were used simultaneously, and the absolute frequency determination using a frequency comb yielded an accuracy in the isotope-shift measurements of about 1 MHz.
View Article and Find Full Text PDFAtom trap trace analysis, a novel method based upon laser trapping and cooling, is used to count individual atoms of 41Ca present in biomedical samples with isotopic abundance levels between 10(-8) and 10(-10). The method is calibrated against resonance ionization mass spectrometry, demonstrating good agreement between the two methods. The present system has a counting efficiency of 2x10(-7).
View Article and Find Full Text PDF