A sensitive, selective rapid bioanalytical assay method was developed and quantification of iloperidone (ILP) and olanzapine (OLZ) in rat plasma was done by mass spectrometry. Systematic sample preparation and extraction procedure were carried out by supported liquid extraction using dichloromethane to extract both the eluents (ILP and OLZ) from rat plasma samples. The extorted samples were injected on a selective Waters XTerra® C18 reverse-phase bonded column (250 × 4.
View Article and Find Full Text PDFA stability-indicating reverse-phase high-performance liquid chromatography-mass spectrometric method was developed and validated for the assay of metaxalone through forced degradation under acidic, alkaline, photo, oxidative and peroxide stress conditions. Separation of degradation products was accomplished on a reverse-phase Phenomenex C18 (250 × 4.6 mm, 5 µm) column thermostated at 25 °C using 10 mM aqueous ammonium acetate: methanol (35:65 v/v) as mobile phase in an isocratic mode of elution.
View Article and Find Full Text PDFA rapid and highly sensitive liquid chromatography-tandem mass spectrometric (LC-MS/MS) method for determination of doxofylline on rat dried blood spots and urine was developed and validated. The chromatographic separation was achieved on a reverse phase C18 column (250 mm × 4.6 mm, 5 μm), using 20 mM ammonium acetate (pH adjusted to 3.
View Article and Find Full Text PDFA validated stability indicating RP-HPLC assay of doxofylline was developed by separating its related substances and degradants on LichrocartC18 (250 mm × 4.6 mm; 5 μm) column using 10 mM ammonium acetate and acetonitrile as a mobile phase in a gradient mode of elution at a flow rate of 1.0 mL/min at 30 °C.
View Article and Find Full Text PDFA highly selective, sensitive and rapid hydrophilic liquid interaction chromatographic method was developed and validated for determination of gemifloxacin on dried blood spots. The chromatographic separation was achieved on a reversed-phase zwitterionic hydrophilic interaction liquid chromatographic ZIC®HILIC-C₁₈ (4.6 × 100 mm; 5 µm) column using acetonitrile-10 mM ammonium acetate (pH 3.
View Article and Find Full Text PDFJ Chromatogr B Analyt Technol Biomed Life Sci
April 2012
A highly sensitive and specific liquid chromatography-electrospray ionization tandem mass spectrometric (LC-ESI-MS/MS) method for investigating the in vivo metabolites of almotriptan in rat plasma, feces and urine was developed. Chromatographic separation was achieved on a Lichrospher RP-18 column (250 mm × 4.6 mm, 5 μm), using 20mM ammonium acetate (pH 3.
View Article and Find Full Text PDFA validated stability indicating RP-HPLC assay of gemifloxacin mesylate was developed by separating its related substances on an Inertsil-ODS3V-C18 (4.6 × 250 mm; 5 μm) column using 0.1% trifluoroaceticacid (pH 2.
View Article and Find Full Text PDF