The implantation of unicortical cortex screws in the proximal hole of locking compression plates (LCP) has been recommended for proximal interphalangeal (PIP) arthrodesis in horses to prevent fractures resulting from stress risers in the proximal phalanx (P1). However, this cortex screw fixation technique may limit efficient dorsal compression of the PIP joint by the plate, potentially affecting the stability of the construct. In this study, we aimed to measure stress and strain in P1 and the plate using an ex vivo model of PIP arthrodesis in horses.
View Article and Find Full Text PDFObjective: The aim of this study was to measure the mechanical properties and failure mode of an model of proximal interphalangeal arthrodesis in horses with different methods of proximal screw fixation using a locking compression plate.
Study Design: Pastern joint arthrodesis with a 3-hole 4.5-mm narrow locking compression plate was performed on 20 forelimbs of equine cadavers, randomized into four groups based on the fixation method and type of proximal screw used: unicortical cortex, bicortical cortex, unicortical locking, bicortical locking.
J Orthop Res
June 2024
Hyperbaric oxygen therapy (HBOT) has proven successful in wound healing. However, its potential effects on anterior cruciate ligament (ACL) injuries remain uncertain. This study aimed to investigate the impact of HBOT on graft healing following ACL reconstruction in rabbits.
View Article and Find Full Text PDFVaccine
January 2024
Background: Influenza vaccination prevents major cardiovascular events in individuals presenting a recent acute coronary syndrome (ACS), however the early effect of an in-hospital double-dose vaccination strategy remains uncertain.
Methods: The VIP-ACS was a randomized, pragmatic, multicenter, open-label trial with a blinded-adjudication endpoint. Patients with ACS ≤ 7 days of hospitalization were randomized to an in-hospital double-dose quadrivalent inactivated influenza vaccine (double-dose) or a standard-dose influenza vaccine at 30 days post-randomization.
Int Immunopharmacol
February 2023
Cinnamaldehyde is a natural product with anti-inflammatory and immune-modulatory properties, known to regulate host responses to bacterial stimuli. This study aimed to investigate the effects of cinnamaldehyde on ligature-induced periodontitis in rats, and its impact on the modulation of human peripheral blood mononuclear cells (PBMC). Male Wistar rats were assigned into three groups:i) control: no ligature + vehicle; ii) ligature: ligature + vehicle; and iii) ligature + cinnamaldehyde (50 mg/kg); all treatments by daily oral gavage.
View Article and Find Full Text PDFAims: To evaluate whether a strategy of double-dose influenza vaccination during hospitalization for an acute coronary syndrome (ACS) compared with standard-dose outpatient vaccination (as recommended by current guidelines) would further reduce the risk of major cardiopulmonary events.
Methods And Results: Vaccination against Influenza to Prevent cardiovascular events after Acute Coronary Syndromes (VIP-ACS) was a pragmatic, randomized, multicentre, active-comparator, open-label trial with blinded outcome adjudication comparing two strategies of influenza vaccination following an ACS: double-dose quadrivalent inactivated vaccine before hospital discharge vs. standard-dose quadrivalent inactivated vaccine administered in the outpatient setting 30 days after randomization.
Objective: The main aim of this study was to compare the biomechanical properties of caudal cervical vertebral stabilization using bicortical transpedicular pins with polymethylmethacrylate (PMMA) versus transvertebral body polyaxial screws and connecting rods with or without an interbody distractor.
Study Design: Ten canine cervical vertebral columns (C2-T3) were used. Four models (intact, transvertebral body polyaxial screw with interbody distractor [polyaxial + distractor], transvertebral body polyaxial screw without interbody distractor [polyaxial - distractor] and bicortical transpedicular pins/polymethylmethacrylate [pin-PMMA]) were applied to C6-7 sequentially on the same specimens.
Herein, a so-called carbon nanotube (CNT) electrode was printed in on a paper substrate using the handwriting technique and carbon nanotube ink in a marker pen to print the working electrode, graphite pencil to print the counter electrode and graphite/silver nanoparticle (AgNP) ink in a rollerball pen to print the quasi-reference electrode. The carbon nanotube electrode was characterized scanning electron microscopy. The electrode was optimized based on the type of paper, hydrophobic barrier and number of layers.
View Article and Find Full Text PDFBackground: Increased risk of new-onset diabetes with statins challenges the long-term safety of this drug class. However, few reports have analyzed this issue during acute coronary syndromes (ACS).
Objective: To explore the association between early initiation of statin therapy and blood glucose levels in patients admitted with ACS.
Objectives: Returning to work after an episode of acute coronary syndrome (ACS) is challenging for many patients, and has both personal and social impacts. There are limited data regarding the working status in the very long-term after ACS.
Methods: We retrospectively analyzed 1,632 patients who were working prior to hospitalization for ACS in a quaternary hospital and were followed-up for up to 17 years.
J Equine Vet Sci
November 2020
The objective of this study was to compare the biomechanical properties in a single cycle axial loading test and the types of failures in two constructs (a 3-hole 4.5-mm dynamic compression plate (DCP) and 7-hole 5.5-mm Y locking compression plate (Y-LCP)) in equine proximal interphalangeal joint (PIJ) arthrodesis.
View Article and Find Full Text PDFPhotoelectrochemical cells have been constructed with photoanodes based on mesoporous titania deposited on transparent electrodes and sensitized in the Visible by nanoparticulate CdS or CdS combined with CdSe. The cathode electrode was an air-breathing carbon cloth carrying nanoparticulate carbon. These cells functioned in the Photo Fuel Cell mode, i.
View Article and Find Full Text PDFTo evaluate the biomechanical effect of graft thickness compared with the double-bundle technique on posterior cruciate ligament (PCL) reconstruction in human cadaveric knees. A total of 9 human cadaveric knees were tested in 5 conditions: intact knee (INT); single-bundle reconstruction with a 10-mm quadriceps tendon (SB); double-bundle reconstruction with a 10 mm-quadriceps tendon for the anterolateral bundle and a 7-mm doubled semitendinosus tendon for the posteromedial bundle (DB); single-bundle reconstruction with a 10-mm quadriceps tendon plus a 7-mm doubled semitendinosus tendon (SBT); and PCL-deficient (NoPCL). The posterior tibial translation (PTT) was measured in response to a 134-N posterior tibial load at 0 , 30 , 60 e 90 of knee flexion.
View Article and Find Full Text PDFBackground And Objective: The number of laparoscopic procedures increases annually with an estimated 3% of complications, one third of them linked to Verres' needle or trocar insertion. The safety and efficacy of ports insertion during laparoscopic surgery may be related the technique but also to trocar design. This study aims to compare physical parameters of abdominal wall penetration for 5 different trocars.
View Article and Find Full Text PDFBackground: The role of beta-blockers in patients with acute coronary syndromes is mainly derived from studies including patients with ST-segment elevation myocardial infarction. Little is known about the use of beta-blockers and associated long-term clinical outcomes in patients with non-ST-elevation acute coronary syndromes (NSTEACS).
Methods: We analyzed short- and long-term clinical outcomes of 2921 patients with NSTEACS using or not oral beta-blockers in the first 24 h of the acute coronary syndromes (ACS) presentation.
Our goal was to develop a novel technique for inducing Achilles tendinopathy in animal models which more accurately represents the progressive histological and biomechanical characteristic of chronic Achilles tendinopathy in humans. In this animal research study, forty-five rabbits were randomly assigned to three groups and given bilateral Achilles injections. Low dose (LD group) (n = 18) underwent a novel technique with three low-dose (0.
View Article and Find Full Text PDFPurpose: To describe the anatomy (quantitative macroscopic and histologic), radiographic parameters of the insertions, and biomechanical characteristics of the medial ligamentous restrictors of the patella (medial patellofemoral ligament [MPFL], medial patellotibial ligament [MPTL], and medial patellomeniscal ligament [MPML]) in cadaveric knees. Because the MPTL and the MPML are not as well known as the MPFL, they were the focus of this study.
Methods: MPFLs, MPTLs, and MPMLs from 9 knees were dissected.
Background: The location of patellar and femoral fixation of the graft in medial patellofemoral ligament reconstructions has been widely discussed. This study aimed to assess the distances between different patellar and femoral fixation points to identify the least anisometric pairs of points.
Methods: Ten cadaver knees were attached to an apparatus that simulated an active range of motion of 120°, with three metallic markers fixed onto the medial side of the patella, and seven markings onto the medial epicondyle.
Background: Recent studies clearly characterize the anatomical parameters of the knee anterolateral ligament (ALL). The potential clinical importance of this ligament is exemplified by some patients with possible combined Anterior Cruciate Ligament (ACL) and ALL rupture who do not progress satisfactorily following isolated ACL reconstruction. Previous biomechanical studies have assessed the resistance parameters of the ALL in order to address potential reconstruction strategies; however, these have reported conflicting results.
View Article and Find Full Text PDFPurpose: Bone block protrusion out of the tibial tunnel due to a relatively long graft is a common complication in anterior cruciate ligament surgical reconstruction with a patellar tendon. One possible solution is to shorten the patellar tendon graft already fixed in the femur by applying external rotation. This study aimed to evaluate the degree of shortening and biomechanical changes in porcine patellar grafts subjected to relatively higher degrees of rotation.
View Article and Find Full Text PDFBackground: The head-shaft angle is used to plan osteotomies and arthroplasties and to assess the radiographic outcomes of surgical treatment for proximal humerus fractures. There are no published data showing whether different degrees of arm rotation interfere with the evaluation of this angle.
Methods: Eighteen humeri from adult cadavers were used.
Objective: To describe and demonstrate the viability of a method for evaluating knee kinematics, by means of a continuous passive motion (CPM) machine, before and after anterior cruciate ligament (ACL) injury.
Methods: This study was conducted on a knee from a cadaver, in a mechanical pivot-shift simulator, with evaluations using optical tracking, and also using computed tomography.
Results: This study demonstrated the viability of a protocol for measuring the rotation and translation of the knee, using reproducible and objective tools (error < 0.