Purpose: Carbon ion therapy treatments can be monitored non-invasively with in-beam Positron Emission Tomography (PET). At CNAO the INSIDE in-beam PET scanner has been used in a clinical trial (NCT03662373) to monitor cancer treatments with proton and carbon therapy. In this work we present the analysis results of carbon therapy data, acquired during the first phase of the clinical trial, analyzing data of nine patients treated at CNAO for various malignant tumors in the head-and-neck region.
View Article and Find Full Text PDFParticle therapy treatments are currently limited by uncertainties of the delivered dose. Verification techniques like Prompt-Gamma-Timing-based Stopping Power Estimation (PGT-SPE) may allow for reduction of safety margins in treatment planning.From Prompt-Gamma-Timing measurements, we reconstruct the spatiotemporal distribution of prompt gamma emissions, which is linked to the average motion of the primary particles.
View Article and Find Full Text PDFThis study addresses a fundamental limitation of in-beam positron emission tomography (IB-PET) in proton therapy: the lack of direct anatomical representation in the images it produces. We aim to overcome this shortcoming by pioneering the application of deep learning techniques to create synthetic control CT images (sCT) from combining IB-PET and planning CT scan data.We conducted simulations involving six patients who underwent irradiation with proton beams.
View Article and Find Full Text PDFIn-beam PET (Positron Emission Tomography) is one of the most precise techniques for in-vivo range monitoring in hadron therapy. Our objective was to demonstrate the feasibility of a short irradiation run for range verification before a carbon-ion treatment. To do so a PMMA target was irradiated with a 220 MeV/u carbon-ion beam and annihilation coincidences from short-lived positron emitters were acquired after irradiations lasting 0.
View Article and Find Full Text PDFMorphological changes that may arise through a treatment course are probably one of the most significant sources of range uncertainty in proton therapy. Non-invasive treatment monitoring is useful to increase treatment quality. The INSIDE in-beam Positron Emission Tomography (PET) scanner performs range monitoring in proton and carbon therapy treatments at the National Center of Oncological Hadrontherapy (CNAO).
View Article and Find Full Text PDFPurpose: In-beam positron emission tomography (PET) is one of the modalities that can be used for in vivo noninvasive treatment monitoring in proton therapy. Although PET monitoring has been frequently applied for this purpose, there is still no straightforward method to translate the information obtained from the PET images into easy-to-interpret information for clinical personnel. The purpose of this work is to propose a statistical method for analyzing in-beam PET monitoring images that can be used to locate, quantify, and visualize regions with possible morphological changes occurring over the course of treatment.
View Article and Find Full Text PDFParticle therapy in which deep seated tumours are treated using C ions (Carbon Ions RadioTherapy or CIRT) exploits the high conformity in the dose release, the high relative biological effectiveness and low oxygen enhancement ratio of such projectiles. The advantages of CIRT are driving a rapid increase in the number of centres that are trying to implement such technique. To fully profit from the ballistic precision achievable in delivering the dose to the target volume an online range verification system would be needed, but currently missing.
View Article and Find Full Text PDFThe high dose conformity and healthy tissue sparing achievable in Particle Therapy when using C ions calls for safety factors in treatment planning, to prevent the tumor under-dosage related to the possible occurrence of inter-fractional morphological changes during a treatment. This limitation could be overcome by a range monitor, still missing in clinical routine, capable of providing on-line feedback. The Dose Profiler (DP) is a detector developed within the INnovative Solution for In-beam Dosimetry in hadronthErapy (INSIDE) collaboration for the monitoring of carbon ion treatments at the CNAO facility (Centro Nazionale di Adroterapia Oncologica) exploiting the detection of charged secondary fragments that escape from the patient.
View Article and Find Full Text PDFPositron emission tomography is one of the most mature techniques for monitoring the particles range in hadron therapy, aiming to reduce treatment uncertainties and therefore the extent of safety margins in the treatment plan. In-beam PET monitoring has been already performed using inter-spill and post-irradiation data, i.e.
View Article and Find Full Text PDFObjectives: To compare unassisted and CAD-assisted detection and time efficiency of radiologists in reporting lung nodules on CT scans taken from patients with extra-thoracic malignancies using a Cloud-based system.
Materials And Methods: Three radiologists searched for pulmonary nodules in patients with extra-thoracic malignancy who underwent CT (slice thickness/spacing 2 mm/1.7 mm) between September 2015 and March 2016.
In vivo range monitoring techniques are necessary in order to fully take advantage of the high dose gradients deliverable in hadrontherapy treatments. Positron emission tomography (PET) scanners can be used to monitor beam-induced activation in tissues and hence measure the range. The INSIDE (Innovative Solutions for In-beam DosimEtry in Hadrontherapy) in-beam PET scanner, installed at the Italian National Center of Oncological Hadrontherapy (CNAO, Pavia, Italy) synchrotron facility, has already been successfully tested in vivo during a proton therapy treatment.
View Article and Find Full Text PDFHadrontherapy is a method for treating cancer with very targeted dose distributions and enhanced radiobiological effects. To fully exploit these advantages, in vivo range monitoring systems are required. These devices measure, preferably during the treatment, the secondary radiation generated by the beam-tissue interactions.
View Article and Find Full Text PDFThe azimuthal anisotropy coefficient v_{2} of prompt D^{0}, D^{+}, D^{*+}, and D_{s}^{+} mesons was measured in midcentral (30%-50% centrality class) Pb-Pb collisions at a center-of-mass energy per nucleon pair sqrt[s_{NN}]=5.02 TeV, with the ALICE detector at the LHC. The D mesons were reconstructed via their hadronic decays at midrapidity, |y|<0.
View Article and Find Full Text PDFParticle therapy exploits the energy deposition pattern of hadron beams. The narrow Bragg Peak at the end of range is a major advantage but range uncertainties can cause severe damage and require online verification to maximise the effectiveness in clinics. In-beam Positron Emission Tomography (PET) is a non-invasive, promising in-vivo technique, which consists in the measurement of the β+ activity induced by beam-tissue interactions during treatment, and presents the highest correlation of the measured activity distribution with the deposited dose, since it is not much influenced by biological washout.
View Article and Find Full Text PDFThe transverse momentum distributions of the strange and double-strange hyperon resonances (, ) produced in p-Pb collisions at TeV were measured in the rapidity range for event classes corresponding to different charged-particle multiplicity densities, d/d. The mean transverse momentum values are presented as a function of d/d, as well as a function of the particle masses and compared with previous results on hyperon production. The integrated yield ratios of excited to ground-state hyperons are constant as a function of d/d.
View Article and Find Full Text PDFBackground And Objective: Standardised Uptake Value (SUV), in clinical research and practice, is a marker of tumour avidity in Positron Emission Tomography/Computed Tomography (PET/CT). Since many technical, physical and physiological factors affect the SUV absolute measurement, the liver uptake is often used as reference value both in quantitative and semi-quantitative evaluation. The purpose of this investigation was to automatically detect the liver position in whole-body PET/CT scans and extract its average SUV value.
View Article and Find Full Text PDFSimultaneous PET/MR/EEG (Positron Emission Tomography - Magnetic Resonance - Electroencephalography), a new tool for the investigation of neuronal networks in the human brain, is presented here within the framework of the European Union Project TRIMAGE. The trimodal, cost-effective PET/MR/EEG imaging tool makes use of cutting edge technology both in PET and in MR fields. A novel type of magnet (1.
View Article and Find Full Text PDFThe measurement of two-particle angular correlations is a powerful tool to study jet quenching in a p_{T} region inaccessible by direct jet identification. In these measurements pseudorapidity (Δη) and azimuthal (Δφ) differences are used to extract the shape of the near-side peak formed by particles associated with a higher p_{T} trigger particle (1
The invariant differential cross sections for inclusive [Formula: see text] and [Formula: see text] mesons at midrapidity were measured in pp collisions at [Formula: see text] TeV for transverse momenta [Formula: see text] GeV/ and [Formula: see text] GeV/, respectively, using the ALICE detector. This large range in [Formula: see text] was achieved by combining various analysis techniques and different triggers involving the electromagnetic calorimeter (EMCal). In particular, a new single-cluster, shower-shape based method was developed for the identification of high-[Formula: see text] neutral pions, which exploits that the showers originating from their decay photons overlap in the EMCal.
View Article and Find Full Text PDFWe present results on transverse momentum ([Formula: see text]) and rapidity ([Formula: see text]) differential production cross sections, mean transverse momentum and mean transverse momentum square of inclusive [Formula: see text] and [Formula: see text] at forward rapidity ([Formula: see text]) as well as [Formula: see text]-to-[Formula: see text] cross section ratios. These quantities are measured in pp collisions at center of mass energies [Formula: see text] and 13 TeV with the ALICE detector. Both charmonium states are reconstructed in the dimuon decay channel, using the muon spectrometer.
View Article and Find Full Text PDFAutomatic detection of pulmonary nodules in thoracic computed tomography (CT) scans has been an active area of research for the last two decades. However, there have only been few studies that provide a comparative performance evaluation of different systems on a common database. We have therefore set up the LUNA16 challenge, an objective evaluation framework for automatic nodule detection algorithms using the largest publicly available reference database of chest CT scans, the LIDC-IDRI data set.
View Article and Find Full Text PDFWe present the first azimuthally differential measurements of the pion source size relative to the second harmonic event plane in Pb-Pb collisions at a center-of-mass energy per nucleon-nucleon pair of sqrt[s_{NN}]=2.76 TeV. The measurements have been performed in the centrality range 0%-50% and for pion pair transverse momenta 0.
View Article and Find Full Text PDFThe azimuthal correlations of D mesons with charged particles were measured with the ALICE apparatus in pp collisions at [Formula: see text] and p-Pb collisions at [Formula: see text] at the Large Hadron Collider. [Formula: see text], [Formula: see text], and [Formula: see text] mesons and their charge conjugates with transverse momentum [Formula: see text] and rapidity in the nucleon-nucleon centre-of-mass system [Formula: see text] (pp collisions) and [Formula: see text] (p-Pb collisions) were correlated to charged particles with [Formula: see text]. The yield of charged particles in the correlation peak induced by the jet containing the D meson and the peak width are compatible within uncertainties in the two collision systems.
View Article and Find Full Text PDF