Quantifying airway smooth muscle (ASM) in patients with asthma raises the possibility of improved and personalized disease management. Endobronchial polarization-sensitive optical coherence tomography (PS-OCT) is a promising quantitative imaging approach that is in the early stages of clinical translation. To date, only animal tissues have been used to assess the accuracy of PS-OCT to quantify absolute (rather than relative) ASM in cross sections with directly matched histological cross sections as validation.
View Article and Find Full Text PDFSignificance: Post-burn scars and scar contractures present significant challenges in burn injury management, necessitating accurate evaluation of the wound healing process to prevent or minimize complications. Non-invasive and accurate assessment of burn scar vascularity can offer valuable insights for evaluations of wound healing. Optical coherence tomography (OCT) and OCT angiography (OCTA) are promising imaging techniques that may enhance patient-centered care and satisfaction by providing detailed analyses of the healing process.
View Article and Find Full Text PDFPolarization-sensitive optical coherence tomography (PS-OCT) measures the polarization states of the backscattered light from tissue that can improve angiography based on conventional optical coherence tomography (OCT). We present a feasibility study on PS-OCT integrated with deep learning for PS-OCT angiography (PS-OCTA) imaging of human cutaneous microvasculature. Two neural networks were assessed for PS-OCTA, including the residual dense network (RDN), which previously showed superior performance for angiography with conventional OCT and the upgraded grouped RDN (GRDN).
View Article and Find Full Text PDFDiabetes affects the structure of the blood vessel walls. Since the blood vessel walls are made of birefringent organized tissue, any change or damage to this organization can be evaluated using polarization-sensitive optical coherence tomography (PS-OCT). In this paper, we used PS-OCT along with the blood vessel wall birefringence index (BBI = thickness/birefringence) to non-invasively assess the structural integrity of the human retinal blood vessel walls in patients with diabetes and compared the results to those of healthy subjects.
View Article and Find Full Text PDFTwo designs with a multiplexed superluminescent diode for ultra-high-resolution spectral-domain polarization-sensitive optical coherence tomography (UHR-PS-OCT) are introduced. In the first design, a Wollaston prism separates orthogonal polarization states next to each other on one linescan camera; the other design uses a beam displacer to separate orthogonal states onto two lines of a linescan camera with multiple rows of detectors. The coherence lengths measured with the two systems were 3.
View Article and Find Full Text PDF[This corrects the article on p. 1386 in vol. 13, PMID: 35414965.
View Article and Find Full Text PDFPolarization-sensitive optical coherence tomography (PS-OCT) derived birefringence values effectively identify skeletal muscle structural disruption due to muscular dystrophy and exercise-related muscle damage in animal models in tissue. The purpose of this investigation was to determine if a PS-OCT needle probe inserted into the leg of a human subject could accurately identify various anatomical structures with implications for use as a diagnostic tool for the determination of skeletal muscle pathology. A healthy middle-aged subject participated in this study.
View Article and Find Full Text PDFClinical visualization and quantification of the amount and distribution of airway smooth muscle (ASM) in the lungs of individuals with asthma has major implications for our understanding of airway wall remodeling as well as treatments targeted at the ASM. This paper theoretically investigates the feasibility of quantifying airway wall thickness (focusing on the ASM) throughout the lung in vivo by means of bronchoscopic polarization-sensitive optical coherence tomography (PS-OCT). Using extensive human biobank data from subjects with and without asthma in conjunction with a mathematical model of airway compliance, we define constraints that airways of various sizes pose to any endoscopic imaging technique and how this is impacted by physiologically relevant processes such as constriction, inflation and deflation.
View Article and Find Full Text PDFSelective retinal therapy (SRT) employs a micro-second short-pulse lasers to induce localized destruction of the targeted retinal structures with a pulse duration and power aimed at minimal damage to other healthy retinal cells. SRT has demonstrated a great promise in the treatment of retinal diseases, but pulse energy thresholds for effective SRT procedures should be determined precisely and in real time, as the thresholds could vary with disease status and patients. In this study, we present the use of a multi-port fiber-based interferometer (MFI) for highly sensitive real-time SRT monitoring.
View Article and Find Full Text PDFA new method based on polarization-sensitive optical coherence tomography (PS-OCT) is introduced to determine the polarization properties of human retinal vessel walls, . Measurements were obtained near the optic nerve head of three healthy human subjects. The double pass phase retardation per unit depth (DPPR/UD), which is proportional to the birefringence, is higher in artery walls, presumably because of the presence of muscle tissue.
View Article and Find Full Text PDFGlaucomatous damage can be quantified by measuring the thickness of different retinal layers. However, poor image quality may hamper the accuracy of the layer thickness measurement. We determined the effect of poor image quality (low signal-to-noise ratio) on the different layer thicknesses and compared different segmentation algorithms regarding their robustness against this degrading effect.
View Article and Find Full Text PDFIn this Letter, we describe a single-pixel polarization-sensitive imaging technique, capable of generating the birefringence map of a thin specimen by using single-pixel detectors. Spatially modulated light is circularly polarized to illuminate the specimen. The transmitted light through the specimen is then focused via a lens and measured by position-sensitive detectors in two orthogonal polarization channels.
View Article and Find Full Text PDFTerahertz (THz) imaging and optical coherence tomography (OCT) provide complementary information with similar length scales. In addition to OCT's extensive use in ophthalmology, both methods have shown some promise for other medical applications and non-destructive testing. In this paper, we present an iterative algorithm that combines the information from OCT and THz imaging at two different measurement locations within an object to determine both the depth of the reflecting layers at the two locations and the unknown refractive index of the medium for both the OCT wavelengths and THz frequencies.
View Article and Find Full Text PDFThe organization of fibrillar tissue on the micrometer scale carries direct implications for health and disease but remains difficult to assess . Polarization-sensitive optical coherence tomography measures birefringence, which relates to the microscopic arrangement of fibrillar tissue components. Here, we demonstrate a critical improvement in leveraging this contrast mechanism by employing the improved spatial resolution of focus-extended optical coherence microscopy (1.
View Article and Find Full Text PDFWe present a new optical coherence tomography (OCT) angiography method for imaging tissue microvasculature based on the characteristic frequency-domain flow signature in a short time series of a single voxel. The angiography signal is generated by Fourier transforming the OCT signal time series from a given voxel in multiple acquisitions and computing the average magnitude of non-zero (high-pass) frequency components. Larger temporal variations of the OCT signal caused by blood flow result in higher values of the average magnitude in the frequency domain compared to those from static tissue.
View Article and Find Full Text PDFAs data acquisition for retinal imaging with optical coherence tomography (OCT) becomes faster, efficient collection of photons becomes more important to maintain image quality. One approach is to use a larger aperture at the eye's pupil to collect more photons that have been reflected from the retina. A 2.
View Article and Find Full Text PDFMorphological changes in the outer retina such as drusen are established biomarkers to diagnose age-related macular degeneration. However, earlier diagnosis might be possible by taking advantage of more subtle changes that accompany tissues that bear polarization-altering properties. To test this hypothesis, we developed a method based on polarization-sensitive optical coherence tomography with which volumetric data sets of the macula were obtained from 10 young (<25 years) and 10 older (>54 years) subjects.
View Article and Find Full Text PDFAn optical coherence tomography (OCT) system with a 2.8-mm beam diameter is presented. Sensorless defocus correction can be performed with a Badal optometer and astigmatism correction with a liquid crystal device.
View Article and Find Full Text PDFOptical coherence tomography (OCT) images of the retina are inevitably affected by the finite width of the coherence function and noise. To make low-reflective layers visible, the raw OCT signal is log transformed; to reduce the effect of noise the images can be low-pass filtered. We determined the effects of these operations on layer thickness assessment, as a function of signal-to-noise ratio (SNR), by performing measurements in a phantom eye and modeling.
View Article and Find Full Text PDFA general mathematical model based on Mueller-matrix calculation is presented to describe the optical behavior of a dual-crystal electro-optic modulator. The two crystals inside the modulator are oriented at ± 45° with respect to the horizontal, thereby cancelling natural birefringence and temperature-induced birefringence. We describe the behavior of the modulator as a function of the ellipticity of the crystals, the rotation angles of the crystals and the applied voltage.
View Article and Find Full Text PDFA growing body of evidence suggests that phototransduction can be studied in the human eye in vivo by imaging of fast intrinsic optical signals (IOS). There is consensus concerning the limiting influence of motion-associated imaging noise on the reproducibility of IOS-measurements, especially in those employing spectral-domain optical coherence tomography (SD-OCT). However, no study to date has conducted a comprehensive analysis of this noise in the context of IOS-imaging.
View Article and Find Full Text PDFWe propose ultra-high resolution optical coherence tomography to study the morphological development of internal organs in medaka fish in the post-embryonic stages at micrometer resolution. Different stages of Japanese medaka were imaged after hatching in vivo with an axial resolution of 2.8 µm in tissue.
View Article and Find Full Text PDFThe transfer function for optical wavefront aberrations in single-mode fiber based optical coherence tomography is determined. The loss in measured OCT signal due to optical wavefront aberrations is quantified using Fresnel propagation and the calculation of overlap integrals. A distinction is made between a model for a mirror and a scattering medium model.
View Article and Find Full Text PDF