Publications by authors named "Cemal Aydin"

The purpose of the present study is to evaluate the fracture resistance and the fit of CAD-CAM produced inlay-retained fixed partial dentures. Eighteen experimental groups were generated according to different CAD-CAM ceramic materials (zirconia, lithium disilicate, and zirconia-reinforced lithium silicate), different connector dimensions (12, 14, and 16 mm), and application of thermomechanical-aging (1,200,000 cycles of cyclic loading with simultaneous thermal cycling). Gap values of thermomechanically-aged groups were measured by using periapical radiographs.

View Article and Find Full Text PDF

Statement Of Problem: Silicone elastomers have been widely used for rehabilitation of facial defects for more than 50 years. However, color change is the most common problem limiting the service life of facial prostheses. Whether the addition of ultraviolet protectives may enhance color stability of these materials is unclear.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to investigate the fracture resistance and failure modes of different non-aged and aged abutment/crown systems.

Materials And Methods: One hundred dental implants (diameter 4.3 mm and length 11.

View Article and Find Full Text PDF

This study compared the fracture resistance of monolithic and veneered all-ceramic four-unit posterior fixed dental prostheses (FDPs) generated by computer-aided design/computer-aided manufacturing (CAD/CAM) after aging in a mastication simulator. Four-unit FDPs were designed from six different all-ceramic systems: 1) monolithic lithium disilicate (M-E), 2) monolithic zirconia (M-TZI), 3) veneered zirconia by conventional layering (V-L), 4) veneered zirconia by lithium disilicate pressing (V-P), 5) veneered zirconia by lithium disilicate fusing (CAD-F-E), and 6) veneered zirconia by feldspathic ceramic cementing (CAD-C-CB). The specimens were divided into control and aging groups (n = 10 per group).

View Article and Find Full Text PDF

Background: Glass fiber-reinforced posts have been preferred frequently because of some physical properties similar to the dentin, chemically bonding to dentin, biocompatibility, and esthetics.

Objective: This study aimed to evaluate the microleakage and bond strength of glass fiber posts cemented with various adhesive systems on laser-etched root canal walls.

Methods: Roots of 120 human mandibular premolars were divided into two groups for push-out bond strength test and the microleakage test (n = 60).

View Article and Find Full Text PDF

The purpose of the present study was to evaluate and compare the fracture strength and failure modes of endocrowns, zirconia post, and fiber post supported restorations and predict the clinical outcomes of six different prostheses used for endodontically treated teeth. Sixty (n=10) maxillary central incisors were restored with zirconia post/resin-nano-ceramic crown (ZrRNC), fiber post/resinnano-ceramic crown (FbRNC), zirconia post/lithium disilicate ceramic crown (ZrLDS), fiber post/lithium disilicate ceramic crown (FbLDS), resin-nano-ceramic endocrown (EndoRNC), and lithium disilicate ceramic endocrown (EndoLDS). Fracture strength test was performed.

View Article and Find Full Text PDF

Background/aim: Despite the importance of hip fractures, very few studies have assessed their epidemiological characteristics in Turkey. The aim of this study was to evaluate the frequency and demography of hip fractures from the recent data of a central training and research hospital.

Materials And Methods: In this descriptive study, we identified hip fracture cases between 2009 and 2013.

View Article and Find Full Text PDF

Background/purpose: The aim of this study was to evaluate implant survival, crestal bone level changes, and clinical parameters of IDcam dental implants over a mean follow-up period of 3 years.

Materials And Methods: Seventy-two patients, 32 females and 40 males, received 255 implants. Implant-supported metal-ceramic fixed restorations were inserted.

View Article and Find Full Text PDF

Purpose: To evaluate the accuracy of the CEREC CAD/CAM system in reproducing the maximum intercuspal contacts of the casts, which include posterior teeth preparation for a fixed partial denture (FPD).

Materials And Methods: Ten pairs of gypsum casts were mounted in articulators in maximum intercuspal position (MIP) to serve as patient simulation models. Tooth #19 was removed from the cast.

View Article and Find Full Text PDF

We investigated the isokinetic performance of hip muscles and clinical outcomes after revision total hip arthroplasty (THA) via same anterolateral approach used in primary surgery. Thirty patients who had undergone previous THA via an anterolateral approach underwent both acetabular and femoral component revision after aseptic loosening. The Harris Hip Score (HHS) was evaluated during a minimum 2-year follow-up.

View Article and Find Full Text PDF

Statement Of Problem: Veneered zirconia restorations are widely used in prosthetic applications. However, these restorations often fail because of chipping of the veneer porcelain. Surface treatments of zirconia core materials may affect the connection between the 2 layers.

View Article and Find Full Text PDF

Due to the possible aesthetic problems of titanium implants, the developments in ceramic implant materials are increasing. Natural tooth colored ceramic implants may be an alternative to overcome aesthetic problems. The purpose of this article is to give information about the basic properties of dental zirconia implants and present 3 cases treated with two-piece zirconia implants.

View Article and Find Full Text PDF

Purpose: The purpose of the present study was to evaluate the effect of thermocycling and mechanical loading on the biaxial flexural strength and the phase transformation of one Ce-TZP/Al2O3 and two Y-TZP core materials.

Materials And Methods: Thirty disc-shaped specimens were obtained from each material. The specimens were randomly divided into three groups (control, thermocycled, and mechanically loaded).

View Article and Find Full Text PDF

Purpose: Posterior-cruciate-ligament-retaining (PCR) and posterior-cruciate-ligament-stabilized (PS) arthroplasties are two major common practices in total knee arthroplasty (TKA). The hypothesis of the present study was that compared with the PCR technique, the PS technique is associated with a higher amount of postoperative blood loss and greater need for blood transfusion in cemented TKA.

Methods: In this prospective, randomized study, 100 patients diagnosed with primary knee osteoarthritis were randomly assigned to either the PCR group (Group I) or the PS group (Group II).

View Article and Find Full Text PDF

It can be difficult to achieve a natural appearance in the anterior region with implant-supported restorations because metal components may show through the soft tissue. Zirconia implants, therefore, should be considered as an alternative treatment for improved esthetics. The goal of this clinical report was to evaluate a new 2-piece zirconia implant system for the maxillary anterior region.

View Article and Find Full Text PDF

Purpose: The aim of the present study was to evaluate the effect of splinting titanium (Ti) or zirconia (Zr) implants supporting maxillary anterior fixed prostheses on the stress levels and patterns in the implants, prostheses, and the surrounding bone; and to compare the effects of Zr and Ti implant materials on the stress distribution in splinted and nonsplinted designs via finite element modeling.

Materials And Methods: Zr and Ti dental implants and the anterior maxilla were modeled. In the nonsplinted design (D1), implants were placed into the maxillary left central incisor and canine regions, and a three-unit zirconia fixed prosthesis was modeled.

View Article and Find Full Text PDF

Statement Of Problem: Clinical studies on implant-retained maxillofacial prostheses have focused on biological outcomes. An assessment of the effect of prostheses on patients' quality of life (QOL) by using specific questionnaires developed for this patient population provides important information on treatment outcomes from the patients' perspectives.

Purpose: The purpose of this study was to report patient-based outcomes of implant-retained maxillofacial prostheses and to evaluate the effect of implant-retained maxillofacial prostheses on QOL of participants in a prospective study.

View Article and Find Full Text PDF

Background: Traumatic amputation of fingers results in a serious impairment of hand function and affects the psychological status of the patients. The implant-retained finger prostheses are an alternative treatment. The aim of this case report is to represent the use of osseointegrated implants for retention of finger prostheses in a patient with amputated thumb and index finger.

View Article and Find Full Text PDF

Purpose: The purpose of this pilot study was to apply resonance frequency analysis (RFA) to measure the clinical stability of craniofacial implants and compare the RFA measurements over a 12-month period.

Materials And Methods: Patients with auricular or orbital defects were treated with prostheses retained by two or three implants. After healing periods of 3 months for auricular implants and 6 months for orbital implants, prostheses were fabricated.

View Article and Find Full Text PDF

The aim of this study was to evaluate the effect of fatigue on fracture toughness and phase transformation of yttria-stabilized zirconia polycrystal materials (Cercon and Lava). The specimens were tested for indentation fracture toughness either with or without being subjected to fatigue (20,000 cycles, 2 Hz, 200 N load). X-ray diffraction (XRD) analysis was used to examine the phase composition of specimens.

View Article and Find Full Text PDF

Reconstruction of facial organ and tissue losses using autogenous tissue is a permanent and effective method in plastic surgery. However, in cases where the patient's general condition does not allow for surgical reconstruction or where the patient is in need of reconstruction of complex organs such as the eye, nose, or ear, an epithesis can be considered as an alternative to treatment with autogenous tissue. The purpose of this study was to investigate the factors affecting the success rate of facial reconstructions with an externally retained prosthesis in relation to the defect location and radiotherapy treatment.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to compare the von Mises (vM), compressive, and tensile stresses occurring on implants, abutments, and surrounding bone using three-dimensional finite element analysis (FEA) in three simulations in the anterior maxilla: a single titanium implant with a titanium abutment, a single titanium implant with a zirconia abutment, and a single one-piece zirconia implant.

Materials And Methods: Three types of implants (all were 4 x 12 mm) were modeled using FEA: Astra OsseoSpeed implant with titanium abutment (ATt), Astra OsseoSpeed with zirconia abutment (ATz), and White-SKY (WS) one-piece zirconia dental implant. The anterior maxillary bone was also simulated with FEA.

View Article and Find Full Text PDF

This article describes a time-saving technique for fabricating a new implant-retained orbital prosthesis using the patient's existing prosthesis. The location of the ocular component is transferred; the position and openings of the palpebral anatomic structures and the precise anatomic details of the existing orbital prosthesis are duplicated. Making the impression, fabricating the definitive cast, alignment of the ocular component, and completing the wax sculpture of the prosthesis are accomplished in one appointment.

View Article and Find Full Text PDF

Objectives: The aim of this study was to evaluate the effect of fatigue on biaxial flexural strength of bilayered disks of two Y-TZP cores.

Methods: Twenty bilayered veneer/zirconia disks were fabricated from each material (Lava veneer+core, 3M/ESPE, and Cercon veneer+core, Densply). Ten specimens from each material were tested for biaxial flexural strength either with or without being subjected to fatigue (20,000 cycles, 2 Hz, 200 N load) in a universal testing machine (1mm/min).

View Article and Find Full Text PDF

Purpose: Extraoral implants provide the prostheses excellent stability and retention. However, the use of implants in the orbit showed questionable survival rates. Furthermore, evaluation of this treatment from the patients' point of view is lacking in clinical studies.

View Article and Find Full Text PDF