Background: The aim of this study was to evaluate the nanoleakage and microtensile bond strength (μTBS) of an ethanol based-adhesive containing Titanium dioxide (TiO2) nanofibers to dentin.
Material And Methods: TiO2 nanofiber was produced by electrospinning and it was inserted in an ethanol-based adhesive in 0.5, 1.
Background: The aim was to estimate the prevalence of reuse of healing abutments, the methods used in disinfection and to analyze the reasons that lead to the reuse of these components by professionals who work in rehabilitation with dental implants.
Material And Methods: For this, an online data collection was carried out through a questionnaire developed in Google Forms. This questionnaire was applied to 284 specialists in implantology, randomized, of the 1,147 registered in the Regional Council of Dentistry of Rio Grande do Sul.
J Dent Res Dent Clin Dent Prospects
August 2021
Direct pulp capping is a method designed to preserve the exposed dental pulp. Due to good biological, physical, and mechanical properties, new versions of calcium silicate-based materials have been developed as pulp capping materials. The present study aimed to evaluate the cytotoxic effects of four calcium silicate-based pulp capping materials, of which the Bio-C Repair Íon+ is still in an experimental phase.
View Article and Find Full Text PDFPurpose: The potential of UV-mediated photofunctionalization to enhance the resin-based luting agent bonding performance to aged materials was investigated.
Methods: Sixty samples of each material were prepared. Yttria-stabilized zirconia (YZr) and Pd-Au alloy (Pd-Au) plates were fabricated and sandblasted.
To assess, in vitro, the influence of heat air treatment on cytotoxicity and degree of conversion (DC) of universal self-etch adhesives (Ambar Universal APS, Scotchbond Universal Adhesive, and Tetric N-Bond Universal) in an NIH/3T3 fibroblast cell culture. Samples were divided into three groups: 1) no heat treatment (control), 2) 37°C and 3) 60°C heat treatment before photopolymerization. Cytotoxicity was analyzed by MTT assay and the DC by FTIR.
View Article and Find Full Text PDFBackground: The light-cured calcium hydroxide based cements have incomplete polymerization and unconverted monomers can cause pulp cell damage. The aim of this study was to evaluate the influence of a warm and hot air stream on the cytotoxicity of light-cured calcium hydroxide based cements.
Material And Methods: The materials Dycal (conventional cement), Biocal, Hidrox-Cal, and Ultra-Blend Plus (light-cured calcium hydroxide cements) were submitted to cytotoxicity analysis after polymerization, without vs.
The purpose was to evaluate the effect of a hydrophilic amide monomer on μTBS of one-step adhesive to dentin at different application times. Clearfil Universal Bond Quick (UBQ), experimental adhesive (UBQ; same compositions as UBQ but hydrophilic amide monomer was replaced with 2-hydroxyethyl methacrylate), Clearfil SE ONE and Clearfil SE Bond were applied to midcoronal dentin prepared with 600-grit SiC at different application time (0, 10, 20 and 40 s). Water sorption (Wsp) and the ultimate tensile strength (UTS) of polymerized adhesives were also measured.
View Article and Find Full Text PDFObjectives: Ultra-high-speed (UHS) videography was used to visualize the fracture phenomena at the resin-dentin interface during micro-tensile bond strength (μTBS) test. We also investigated whether UHS videography is applicable for failure-mode analysis.
Methods: Ten human mid-coronal dentin surfaces were bonded using Clearfil SE Bond either in self-etching (SE) or etch-and-rinse (ER) mode.
The burning mouth syndrome (BMS) has no specific clinical and laboratory signs. Its etiology is yet to be elucidated, but it is considered to be affected by multifactorial, psychological, and local and systemic factors. This condition is considered of great morbidity, and the main complaint of patients maybe associated with xerostomia, thirst, and altered taste.
View Article and Find Full Text PDFObjective: This study evaluated the effect of air temperature (warm or cold) for solvent evaporation on bonding and nanoleakage of self-etching adhesives to dentin.
Materials And Methods: The adhesives Clearfil 3S Bond [S3], OptiBond All-In-One [OB], Adper SE Plus [AD], and Silorane adhesive [SI] were applied on dentin surfaces, and a warm (60 ± 2°C) or cold air (20 ± 1°C) was applied and light-cured. After water storage (24 h), the teeth were sectioned into sticks (0.
Objectives: This study aimed to compare the micro-tensile bond strength of methacrylate resin systems to a silorane-based restorative system on dentin after 24 hours and six months water storage.
Material And Methods: The restorative systems Adper Single Bond 2/Filtek Z350 (ASB), Clearfil SE Bond/Z350 (CF), Adper SE Plus/Z350 (ASEP) and P90 Adhesive System/Filtek P90 (P90) were applied on flat dentin surfaces of 20 third molars (n=5). The restored teeth were sectioned perpendicularly to the bonding interface to obtain sticks (0.
Objective: This randomized double-blind clinical trial compared the performance of posterior composite restorations with or without bevel, after 1-year follow-up.
Material And Methods: Thirteen volunteers requiring at least two posterior composite restorations were selected. Twenty-nine cavities were performed, comprising 14 without bevel (butt joint) and 15 with bevel preparation of the enamel cavosurface angle.
Purpose: This study evaluated the effect of prolonged polymerization times on the microtensile resin-dentin bond strength (μTBS), degree of conversion of adhesive films (DC) and silver nitrate uptake (SNU) for an ethanol/water- (Adper Single Bond 2, [SB]) and an acetone-based (One Step Plus, [OS]) etch-and-rinse adhesive.
Materials And Methods: Thirty caries-free extracted molars were included in this study. The occlusal enamel of all teeth was removed by wet grinding the occlusal enamel on 180-grit SiC paper.
The aim of this study was to evaluate the fracture strength of teeth with different cavosurface margin cavity preparations and restored with composite resin and different adhesive systems. Eighty premolars were randomly divided in 8 groups, as follow: G1- sound teeth; G2- MOD preparation (no restoration); G3- Adper Single Bond without bevel preparation (butt joint); G4- Adper Single Bond with bevel preparation; G5- Adper Single Bond with chamfer preparation; G6- Clearfil SE Bond without bevel (butt joint); G7- Clearfil SE Bond with bevel preparation; G8- Clearfil SE Bond with chamfer preparation. The adhesive systems were applied according to manufacturers' instructions.
View Article and Find Full Text PDFObjective: To evaluate the effects of surface treatment and intermediate agent hydrophilicity on durability of the composite repair by means of the microtensile bond strength test (microTBS) and silver nitrate uptake (SNU) and the effects of surface treatment on composite roughness (Ra) and micromorphological features (SEM).
Methods: Thirty resin composite blocks (4x6x6 mm) (Opallis, FGM) were polished after seven days and divided into three groups: no treatment (NT); roughening with a fine-grit diamond bur (DB); 50 microm aluminum oxide sandblasting (AO). A hydrophobic (Adhesive bottle, Scotchbond MultiPurpose [SBMP]) or hydrophilic adhesive (Adper Single Bond 2 [SB]) was then applied.
Aim: This double-blind randomized clinical trial compared the performance of posterior composite restorations with and without bevel.
Methods And Materials: Thirteen volunteers requiring at least two posterior Class II restorations were selected. Twenty-nine cavity preparations were performed, comprising 14 without bevel (butt joint) and 15 with marginal beveling.
Objectives: The aim of this study was to test the effect of adhesive temperature on the bond strength to dentin (muTBS) and silver nitrate uptake (SNU) of an ethanol/water (Adper Single Bond 2 [SB]) and an acetone-based (Prime&Bond 2.1 [PB]) etch-and-rinse adhesive system.
Methods: The bottles of each adhesive were kept in various temperatures (5 degrees C, 20 degrees C, 37 degrees C and 50 degrees C) for 1h previously to its application in the occlusal demineralized dentin of 40 molars.
Objectives: This study evaluated the effect of a warm or cold air-dry stream for solvent evaporation on the microtensile resin-dentin bond strength (muTBS), nanoleakage pattern (SEM), degree of conversion (DC) and solvent evaporation rates (SE) of an ethanol/water- (Adper Single Bond, [SB] 3MESPE) and an acetone-based (Prime & Bond 2.1, [PB] Dentsply), two-step etch-and-rinse adhesive system.
Materials And Methods: Adhesives were applied on demineralized dentin surfaces.
Objectives: This study evaluated the immediate and 6-month resin-dentin micro-bond strength (microTBS) of one-step self-etch systems (Adper Prompt L-Pop [AD] 3M ESPE; Xeno III [XE] Dentsply De Trey; iBond [iB] Heraeus Kulzer) under different application modes.
Materials And Methods: Dentin oclusal surfaces were exposed by grinding with 600-grit SiC paper. The adhesives were applied according to the manufacturer's directions [MD], or with double application of the adhesive layer [DA] or following the manufacturer's directions plus a hydrophobic resin layer coating [HL].