A novel suite of instrumentation for the characterisation of materials held inside an air-tight tube furnace operated up to 250 °C has been developed. Real-time detection of released gases (volatile organic compounds (VOCs), CO, NO, NO, SO, CO and O) was achieved combining commercial off-the-shelf (COTS) gas sensors and sorbent tubes for further qualitative and semi-quantitative analysis by gas chromatography-mass spectrometry coupled to thermal desorption (TD-GC-MS). The test system was designed to provide a controlled flow (1000 cm min) of hydrocarbon free air through the furnace.
View Article and Find Full Text PDFWe have investigated the release of gases and volatile organic compounds (VOCs) from a carbon fibre reinforced epoxy composite matrix used in aircraft structural components. Analysis was performed at several temperatures both up to and above the recommended operating temperature (121 °C) for the material, to a maximum of 250 °C. Gas chromatography-mass spectrometry (GC-MS) combined with thermal desorption (TD-GC-MS) was used to identify and quantify VOCs, and in parallel real-time gas detection with commercial off-the-shelf (COTS) gas sensors.
View Article and Find Full Text PDFThe analysis of volatile organic compounds (VOCs) as a non-invasive method for disease monitoring, such as type 2 diabetes (T2D) has shown potential over the years although not yet set in clinical practice. Longitudinal studies to date are limited and the understanding of the underlying VOC emission over the age is poorly understood. This study investigated longitudinal changes in VOCs present in faecal headspace in two mouse models of T2D - Cushing's syndrome and single Afmid knockout mice.
View Article and Find Full Text PDFThe diverse reactivity of [LnO(NO)] complexes with water in the gas phase, for Ln = Ce, Pr and Nd, examined in a quadrupole ion trap and complemented by ab initio computations, illuminates the chemical stability of Pr in the unusual +5 oxidation state.
View Article and Find Full Text PDFDiagnosis of colorectal cancer is an invasive and expensive colonoscopy, which is usually carried out after a positive screening test. Unfortunately, existing screening tests lack specificity and sensitivity, hence many unnecessary colonoscopies are performed. Here we report on a potential new screening test for colorectal cancer based on the analysis of volatile organic compounds (VOCs) in the headspace of faecal samples.
View Article and Find Full Text PDFSeveral lanthanide and actinide tetranitrate ions, M(III)(NO3)4(-), were produced by electrospray ionization and subjected to collision induced dissociation in quadrupole ion trap mass spectrometers. The nature of the MO(NO3)3(-) products that result from NO2 elimination was evaluated by measuring the relative hydrolysis rates under thermalized conditions. Based on the experimental results it is inferred that the hydrolysis rates relate to the intrinsic stability of the M(IV) oxidation states, which correlate with both the solution IV/III reduction potentials and the fourth ionization energies.
View Article and Find Full Text PDFBreath analysis is a promising field with great potential for non-invasive diagnosis of a number of disease states. Analysis of the concentrations of volatile organic compounds (VOCs) in breath with an acceptable accuracy are assessed by means of using analytical techniques with high sensitivity, accuracy, precision, low response time, and low detection limit, which are desirable characteristics for the detection of VOCs in human breath. "Breath fingerprinting", indicative of a specific clinical status, relies on the use of multivariate statistics methods with powerful in-built algorithms.
View Article and Find Full Text PDFFourier transform ion cyclotron resonance mass spectrometry was used to characterize the gas-phase reactivity of Hf dipositive ions, Hf(2+)and HfO(2+), toward several oxidants: thermodynamically facile O-atom donor N(2)O, ineffective donor CO, and intermediate donors O(2), CO(2), NO, and CH(2)O. The Hf(2+) ion exhibited electron transfer with N(2)O, O(2), NO, and CH(2)O, reflecting the high ionization energy of Hf(+). The HfO(2+) ion was produced by O-atom transfer to Hf(2+) from N(2)O, O(2), and CO(2), and the HfO(2)(2+) ion by O-atom transfer to HfO(2+) from N(2)O; these reactions were fairly efficient.
View Article and Find Full Text PDFGas-phase reactions of Ta(2+) and TaO(2+) with oxidants, including thermodynamically facile O-atom donor N(2)O and ineffective donor CO, as well as intermediate donors C(2)H(4)O (ethylene oxide), H(2)O, O(2), CO(2), NO, and CH(2)O, were studied by Fourier transform ion cyclotron resonance mass spectrometry. All oxidants reacted with Ta(2+) by electron transfer yielding Ta(+), in accord with the high second ionization energy of Ta (ca. 16 eV).
View Article and Find Full Text PDFPhosphodiesterase-4 (PDE4) is one of the main enzymes that specifically terminate the action of cAMP, thereby contributing to intracellular signaling following stimulation of various G protein-coupled receptors. PDE4 expression and activity are modulated by agents affecting cAMP levels. The selective PDE4 inhibitor (R)-rolipram labeled with C-11 was tested in vivo in rats to analyze changes in PDE4 levels following drug treatments that increase synaptic noradrenaline (NA), serotonin (5HT), histamine (HA) and dopamine (DA) levels.
View Article and Find Full Text PDFEvidence of disruptions in cAMP-mediated signaling in several neuropsychiatric disorders has led to the development of R-[(11)C]rolipram for imaging phosphodiesterase-4 (PDE4) enzymes with positron emission tomography (PET). The high-affinity PDE4 inhibitor rolipram was previously reported to have an antidepressant effect in humans. PDE4 is abundant in the brain, and it hydrolyzes cAMP produced following stimulation of various neurotransmitter systems.
View Article and Find Full Text PDF