Objectives: This study aims to demonstrate reduced iodine contrast media (CM) in routine abdominal CT scans in portal venous phase (PVP) using a photon-counting detector CT (PCD-CT) compared to total body weight (TBW) and kV-adapted CM injection protocols on a state-of-the-art energy-integrating detector CT (EID-CT) while maintaining sufficient image quality (IQ).
Materials And Methods: Consecutive contrast-enhanced abdominal PVP CT scans from an EID-CT (Nov 2022-March 2024) and a PCD-CT (Sep 2023-Dec 2023) were compared. CM parameters (total iodine load (TIL), iodine delivery rate (IDR) and dosing factor (DF)) were reported.
Background: Since 2011, the International Commission on Radiological Protection (ICRP) has recommended an annual eye lens dose limit of 20 mSv for radiation workers, averaged over 5 years, with no year exceeding 50 mSv. However, limited research has been conducted on dose rate conversion coefficients (DCCs) for direct contamination of the eye.
Purpose: This study aimed to accurately determine DCCs for the eye lens and cornea for ocular contamination with radionuclides used in nuclear medicine.
Objectives: The aim of this study is to improve the reliability of subjective IQ assessment using a pairwise comparison (PC) method instead of a Likert scale method in abdominal CT scans.
Methods: Abdominal CT scans (single-center) were retrospectively selected between September 2019 and February 2020 in a prior study. Sample variance in IQ was obtained by adding artificial noise using dedicated reconstruction software, including reconstructions with filtered backprojection and varying iterative reconstruction strengths.
Objective: To characterize the use and impact of radiation dose reduction techniques in actual practice for routine abdomen CT.
Methods: We retrospectively analyzed consecutive routine abdomen CT scans in adults from a large dose registry, contributed by 95 hospitals and imaging facilities. Grouping exams into deciles by, first, patient size, and second, size-adjusted dose length product (DLP), we summarized dose and technical parameters and estimated which parameters contributed most to between-protocols dose variation.
Objectives: The aims of this study were to develop a proof-of-concept computer algorithm to automatically determine noise, spatial resolution, and contrast-related image quality (IQ) metrics in abdominal portal venous phase computed tomography (CT) imaging and to assess agreement between resulting objective IQ metrics and subjective radiologist IQ ratings.
Materials And Methods: An algorithm was developed to calculate noise, spatial resolution, and contrast IQ parameters. The algorithm was subsequently used on 2 datasets of anthropomorphic phantom CT scans, acquired on 2 different scanners (n = 57 each), and on 1 dataset of patient abdominal CT scans (n = 510).
Objectives: The aim of the study was to find the lowest possible tube current and the optimal iterative reconstruction (IR) strength in abdominal imaging.
Material And Methods: Reconstruction software was used to insert noise, simulating the use of a lower tube current. A semi-anthropomorphic abdominal phantom (Quality Assurance in Radiology and Medicine, QSA-543, Moehrendorf, Germany) was used to validate the performance of the ReconCT software (S1 Appendix).
Ob Jectives: The European Society of Radiology identified 10 common indications for computed tomography (CT) as part of the European Study on Clinical Diagnostic Reference Levels (DRLs, EUCLID), to help standardize radiation doses. The objective of this study is to generate DRLs and median doses for these indications using data from the UCSF CT International Dose Registry.
Methods: Standardized data on 3.
Background: International guideline recommendations on safe use of contrast media (CM) are conflicting regarding the necessity to prewarm iodinated CM.
Purpose: Aim of the study was to evaluate the effects of room temperature CM compared with prewarmed CM on image quality, safety, and patient comfort in abdominal computed tomography (CT).
Methods: CATCHY (Contrast Media Temperature and Patient Comfort in Computed Tomography of the Abdomen) is a double-blinded, randomized noninferiority trial.
Objective: High radiation exposure is a concern because of the association with cancer. The objective was to determine the probability of receiving a high radiation dose from CT (from one or more examinations within a 5-year period) and to assess the clinical context by evaluating clinical indications in the high-dose patient group.
Design: Observational cohort study.
Importance: Computed tomography (CT) radiation doses vary across institutions and are often higher than needed.
Objective: To assess the effectiveness of 2 interventions to reduce radiation doses in patients undergoing CT.
Design, Setting, And Participants: This randomized clinical trial included 864 080 adults older than 18 years who underwent CT of the abdomen, chest, combined abdomen and chest, or head at 100 facilities in 6 countries from November 1, 2015, to September 21, 2017.
Objective: As gonad shielding is currently under debate, this study evaluates the practice, from its introduction in about 1905 until today.
Methods: The literature was searched for developments in shielding and insights into the effects of ionising radiation on gonads. Based on own pre-1927 dose reconstructions, reported doses after 1927, a 2015-report from the European Union and recent own measurements, the effects of technological evolution and optimisation on radiation dose and hereditary risk were assessed.
Purpose: To evaluate conditions for minimizing staff dose in interventional radiology, and to provide an achievable level for radiation exposure reduction.
Materials And Methods: Comprehensive phantom experiments were performed in an angiography suite to evaluate the effects of several parameters on operator dose, such as patient body part, radiation shielding, x-ray tube angulation, and acquisition type. Phantom data were compared with operator dose data from clinical procedures (n = 281), which were prospectively acquired with the use of electronic real-time personal dosimeters (PDMs) combined with an automatic dose-tracking system (DoseWise Portal; Philips, Best, The Netherlands).
Objective: To evaluate the radiation dose for pregnant women and fetuses undergoing commonly used computed tomography of the pulmonary arteries (CTPA) scan protocols and subsequently evaluate the simulated effect of an optimized scan length.
Materials And Methods: A total of 120 CTPA datasets were acquired using four distinctive scan protocols, with 30 patients per protocol. These datasets were mapped to Cristy phantoms in order to simulate pregnancy and to assess the effect of an effective radiation dose (in mSv) in the first, second, or third trimester of pregnancy, including a simulation of fetal dose in second and third trimesters.
Blood-brain barrier (BBB) leakage increases with age and is involved in the pathophysiology of cerebral small vessel disease (cSVD). We examined the relationship between BBB leakage and white matter hyperintensity (WMH) volume and cognition, in cSVD patients and healthy controls. Seventy-seven patients with clinically overt cSVD and thirty-nine age matched healthy controls underwent dynamic contract-enhanced and structural brain MRI and neuropsychological assessment.
View Article and Find Full Text PDFObjective: Diagnostic reference levels (DRLs) are established for standard-sized patients; however, patient dose in CT depends on patient size. The purpose of this study was to introduce a method for setting size-dependent local diagnostic reference levels (LDRLs) and to evaluate these LDRLs in comparison with size-independent LDRLs and with respect to image quality.
Materials And Methods: One hundred eighty-four aortic CT angiography (CTA) examinations performed on either a second-generation or third-generation dual-source CT scanner were included; we refer to the second-generation dual-source CT scanner as "CT1" and the third-generation dual-source CT scanner as "CT2.
Purpose: Radiation safety and protection are a key component of fluoroscopy-guided interventions. We hypothesize that providing weekly personal dose feedback will increase radiation awareness and ultimately will lead to optimized behavior. Therefore, we designed and implemented a personalized feedback of procedure and personal doses for medical staff involved in fluoroscopy-guided interventions.
View Article and Find Full Text PDFPurpose: Dynamic contrast-enhanced (DCE) MRI can be used to measure blood-brain barrier (BBB) leakage. In neurodegenerative disorders such as small vessel disease and dementia, the leakage can be very subtle and the corresponding signal can be rather noisy. For these reasons, an optimized DCE-MRI measurement and study design is required.
View Article and Find Full Text PDFBackground And Purpose: Cerebral small vessel disease (SVD) is associated with cognitive impairment. This may be because of decreased microstructural integrity and microvascular perfusion, but data on these relationships are scarce. We determined the relationship between cognition and microvascular perfusion and microstructural integrity in SVD patients, using intravoxel incoherent motion imaging-a diffusion-weighted magnetic resonance imaging technique designed to determine microvascular perfusion and microstructural integrity simultaneously.
View Article and Find Full Text PDFIntroduction: Cerebral small vessel disease (cSVD) is associated with microvascular and parenchymal alterations. Intravoxel incoherent motion (IVIM) MRI has been proposed to simultaneously measure both the microvascular perfusion and parenchymal diffusivity. This study aimed to evaluate the application of IVIM in cSVD to assess the microvasculature and parenchymal microstructure.
View Article and Find Full Text PDFPurpose: Increased blood-brain barrier (BBB) permeability has been shown to play a significant role in the pathophysiology of cerebrovascular disease and it may provide an early functional marker of progression or treatment effects. The aim of the study was to investigate the test-retest reproducibility and influencing factors of dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) in measuring subtle leakage in patients with cerebrovascular disease.
Material And Methods: DCE-MRI (3T) was performed on two separate days in 16 patients (age 66 ± 9 years) with cerebrovascular disease, prospectively.
Purpose: In the design of nuclear medicine treatment and examination rooms, an important consideration is the shielding required for ionizing radiation from the radioactive isotopes used. The shielding in the walls is normally limited to a height lower than the actual ceiling height. The direct radiation, possibly with build-up correction, can be calculated relatively easily.
View Article and Find Full Text PDFObjective: As blood-brain barrier (BBB) dysfunction may occur in normal aging but may also play a pivotal role in the pathophysiology of cerebral small vessel disease (cSVD), we used dynamic contrast-enhanced (DCE)-MRI to quantify the rate and the spatial extent of BBB leakage in patients with cSVD and age- and sex-matched controls to discern cSVD-related BBB leakage from aging-related leakage.
Methods: We performed structural brain MRI and DCE-MRI in 80 patients with clinically overt cSVD and 40 age- and sex-matched controls. Using the Patlak pharmacokinetic model, we calculated the leakage rate.
Cardiovasc Intervent Radiol
March 2017
Purpose: Knowledge of medical radiation exposure permits application of radiation protection principles. In our center, the first dedicated real-time, automated patient and staff dose monitoring system (DoseWise Portal, Philips Healthcare) was installed. Aim of this study was to obtain insight in the procedural and occupational doses.
View Article and Find Full Text PDFTrauma patients at risk for, or suspected of, spinal injury are frequently transported to hospital using full spinal immobilisation. At the emergency department, immobilisation is often maintained until radiological work-up is completed. In this study, we examined how these devices for spinal stabilization influence visual image quality.
View Article and Find Full Text PDFTrauma patients at risk for, or suspected of, spinal injury are frequently transported to hospital using full spinal immobilisation. At the emergency department, immobilisation is often maintained until radiological work-up is completed. In this study, we examined how these devices influence radiation exposure and noise, as a proxy for objective image quality.
View Article and Find Full Text PDF